Roberts Gorden CGTH-30, CGTH-50, CGTH-40 Carton Contents of Heaters with Galvanized Venting

Page 9

SECTION 2: INTRODUCTION

2.4 Carton Contents of Heaters with Galvanized Venting

Please check the cartons. It should contain the items shown on this page. Contact your ROBERTS GORDON® independent distributor if any items are missing.

(*) Additional package included with select models; also available as an accessory. See Page 5.

Heater Assembly:

A

B C

CGTH-30; CGTH-40; CGTH-50

A.) (1) Hanger P/N 08080000

B.) (1) Reflector End Cap P/N 02750800 C.) (4) U-Clips P/N 91107720

(1) Vent Termination

 

(1) Bird Screen

P/N 08031001

 

P/N 08036000

 

 

 

*5' (125 mm) Balanced Flue Vent package (P/N 08039000) includes:

(1)3" (80 mm) Flue Pipe 66"(168 cm) Long

P/N 08035000

(1)5" (125 mm) Vent Pipe 60" (1520 mm) Long

P/N 90502800

(1)3/8" (10 mm) Manual Gas Shut-off Valve P/N 90100200

°F

l

40

50

60

70

°C

l

l

 

l

 

5

10 15

20

l

OFF

 

 

 

FRONT

(1)Thermostat P/N 90409702

(1)Flue Collar P/N 91911701

(4)Snap Hooks P/N 91903300

Grille (P/N 08050001)

Grille End Cap (P/N 08050002)

Side View

CGTH-Series by

This thermostat controls your overhead tube heater. Keep burner, control compartment and reflector clean. Read your CGTH-Series Use and Care Manual (P/N 180101NA or GH80101NA) and follow all Safety Requirements which include checking your heater monthly. Installation, Service and Annual Inspection must be done by a contractor qualified in the installation and service of gas-fired heating equipment. Please call (716) 852-4400 (USA) or (905) 945-5403 (Canada) if you need a manual or have questions.

Ce thermostat commande votre radiateur. Gardez le module de contrôle et le reflécteur propres. Lisez le manuel d’utilisation et d’entretien CGTH-Series (P/N 180101NA ou GH80101NA) et respectez tous les conseils de sécurité, notamment le contrôle mensuel du radiateur. L’installation, l'entretien et l’inspection annuelle doivent être effectués par un agent agréé. Veuillez nous contactez au 716-852-4400 (USA) ou au 905-945-5403 (Canada) pour toutes questions ou demandes de manuel.

WARNING

 

 

 

 

 

 

 

ATTENTION

 

 

 

 

MOUNT

 

 

 

 

 

 

 

 

THERMOSTAT

 

 

 

 

 

 

 

 

HERE

 

 

 

 

 

 

Fire Hazard

 

 

 

 

 

 

 

 

Risque d'incendie

Some objects will catch fire or

 

 

 

 

 

 

 

Certains objets placés près du

explode when placed close to

 

 

 

 

 

 

 

radiateur peuvent s'enflammer ou

heater.

 

 

 

 

 

 

 

 

 

exploser.

 

 

Keep all flammable objects,

MONTER LE

 

Tenir tous les objets, iquides et

liquids and vapors the required

 

vapeurs inflammables à la

safe distances away from heater.

THERMOSTAT ICI

distance de sécurité requise du

Keep children, clothing and

 

 

 

 

 

 

 

radiateur.

 

 

furniture away from the heater.

 

 

 

 

 

 

 

Surveiffer les enfants. Gardes les

 

 

 

 

 

 

 

 

 

 

vêtements, les meubles loin de

Failure to follow these

 

 

 

 

 

 

 

 

l'appareil.

 

 

instructions will result in death,

 

 

 

 

 

 

 

 

 

 

injury or property damage.

 

 

 

 

 

 

 

Le non-respect de ces consignes

 

 

 

 

 

 

 

 

 

 

peut causer dommage au matériel.

 

 

Required Safe Distances from Combustibles

 

 

 

Distances de Dégagement par Rapport aux Combustibles

 

 

Horizontal Mount

 

Model

A

B

C

D

E

F

45° Mount

 

Montage Horizontal

CGTH-30

4

16

36

28

34

6

Montage à 45°

 

 

 

CGTH-40

4

18

48

30

34

6

24" Min. (61 cm)

 

A

 

 

 

CGTH-50

4

20

48

32

36

6

 

 

 

 

A

 

Modèle

A

B

C

D

E

F

D

 

A

Rating Tag

 

B

CGTH-30

11

41

92

72

87

16

 

 

F

Éttiquette de

C

CGTH-40

11

46

122

77

87

16

 

 

Classement

F

 

E

 

 

B

 

CGTH-50

11

51

122

82

92

16

 

 

 

NOTES: 1. All dimensions are from the reflector.

 

 

NOTES:

1. Toutes les dimensions sont mesurées à partir du réflecteur.

2. Black numerals are in inches. Orange numerals are in

 

 

 

2. Les chiffres noirs sont en pouces. Les chiffres oranges

centimeters.

 

 

 

 

 

 

sont en centimètres.

 

 

3. Know your model number. Model number is found on the

 

 

3. Vous devrez connaître le numéro de votre modèle. Il se

rating tag. (See horizontal mount drawing for location of

 

 

 

trouve sur l’étiquette de classement. (Voir le dessin du

rating tag).

 

 

 

 

 

 

montage horizontal pour l’emplacement de l’étiquette de

 

 

 

 

 

 

 

 

classement).

 

 

 

©

 

www.rg-inc.com

 

 

Printed in U.S.A./Imprimé aux Etats-Unis

P/N

91037903 Rev F

(2)Female Terminals to connect

thermostat wire P/N 91317300

Protective Grille Kits - Included with select models. Also available as an accessory under kit part numbers.

CGTH-30 Kit (P/N 08051000) includes:

(1)Grille End Cap P/N 08050002

(2)Grille without End Cap P/N 08050001

(2)Silicone Cap P/N 91915951-6P

CGTH-40 and CGTH-50 Kit (P/N 08051001) includes:

(3)Grille without End Cap P/N 08050001

(1)Grille End Cap P/N 08050002

(3)Silicone Cap P/N 91915951-6P

(1)Thermostat Tag P/N 91037903

(3)Vent Collar Mounting Screws to attach vent collar to heater

P/N 94118106

Documents:

(1)Installation Manual P/N 180100NA

(1)Use and Care Manual P/N180101NA

(1)Owner Warranty Registration Card:

P/N CGTHWCNA

3

Image 9
Contents Gas-Fired, Low-Intensity Page 2005 Page Table of Figures Page Before YOU Begin 1.1 Read This Manual Questions, Comments or SuggestionsRoberts-Gordon, LLC Unpacking the Heater 2.3.1 Manpower Requirements SafetyAbout the Heater Carton Contents of Heaters with Galvanized Venting Heater Assembly Carton Contents of Heaters with Cox Geelen VentingAvailable as an accessory under kit part numbers Manual Gas Shut-off ValveAvailable Accessories for Galvanized Vent Wall Venting Kit P/N 08032200 includes CGTH-Series by Components Identification Components IdentificationVenting Specifications Heater SpecificationsWhere Cant the Heater Be Installed? Where Can the Heater Be Installed?Meter and Service Gas Service Requirements 3.2.1 Gas TypeElectrical Service Requirements Planning 3.1 GeneralVenting Codes Venting Requirements 3.4.1 System RequirementsBalanced Flue Construction Public GaragesHazardous Locations Safety Equipment InstallationInstallation Tools Installation MaterialsGeneral Venting Guidelines Required Safe Distances from Combustibles Inches Metric cm ModelRemove Shipping Screw from Control Housing Door Hang the HeaterNon-residential applications Dimension Model Minimum Maximum Typical InstallationHorizontal Installation Heater Orientation45 Tilted Installation 13 45 Tilted InstallationSilicone Cap Installation Grille Installation for Select Models OnlyInstall Galvanized Collar Venting InstallationGeneral Venting Requirements United States RequirementsGalvanized Horizontal Venting Galvanized Horizontal Venting with an Elbow Bird Screen InstallationHorizontal Installation Top View Elbow Assembly Assembly Overview Vent Assembly OverviewCox Geelen Horizontal Venting Horizontal Installation Side View Cox Geelen VentingPart Number Description Flue Collar and AdapterCox Geelen Vertical Venting Vertical Venting ConfigurationsVent Clamp Heater Rating 120V, 60 Hz, Single Phase, 1A Electrical Service InstallationThermostat Placement System RequirementsThermostat Installation Rear View GAS Service Installation 7.1 Install Gas Supply Lines Operation 8.1 Operating Instructions TestingTo Turn Off Gas To Heater Sequence of OperationCover Cap Regulator Screw Outlet Pressure Tap Blower does not Come on Possible Cause Try thisIgniter does not Spark Burner does not Light LP GasNatural Gas Manometer Reading Burner Cycles on and OFF TOO Quickly Burner Makes Vibrating Noises While Running Housing door. See Page 17, SectionMaintenance 10.1 Pre-Season Maintenance Connection Diagram Wiring Diagrams 11.1 Connection DiagramLadder Diagram Ladder Diagram Illustrated Parts List for Burner Illustrated Parts List Replacement PartsReplacement Parts List for Burner Part Number Description CGTH-30 CGTH-40 CGTH-50 Warranty is Void if ROBERTS-GORDON will not PAY forLimitations on Authority Representatives Page Owner Warranty Registration Card Page
Related manuals
Manual 30 pages 54.92 Kb

CGTH-40, CGTH-50, CGTH-30 specifications

Roberts Gordon is a renowned manufacturer known for its innovative heating solutions, particularly in the realm of infrared heaters. Among their product lineup, the CGTH series, which includes the CGTH-50, CGTH-40, and CGTH-30 models, exemplifies high-performance technology tailored specifically for industrial and commercial applications.

The CGTH series is designed for versatility and efficiency, offering advanced features that enhance the heating experience in various environments. One of the standout features of these heaters is their infrared technology, which provides targeted warmth, making them ideal for large, open spaces such as warehouses, factories, and sporting facilities. Infrared heaters work by directly heating objects and people in their path rather than the air, ensuring quicker warmth and greater energy efficiency.

Each model offers different heating capacities, with the CGTH-50 boasting a maximum output of 50,000 BTUs, the CGTH-40 providing up to 40,000 BTUs, and the CGTH-30 generating 30,000 BTUs. This variety allows users to choose a model that best fits their heating needs based on the size and requirements of their space.

The units are designed for easy installation, featuring a modular design that allows for both indoor and outdoor applications. Moreover, the heaters can be integrated with various control systems, including programmable thermostats and remote management, enhancing user convenience and optimizing energy usage.

A critical aspect of the CGTH series is its emphasis on durability and safety. Each model is crafted using high-quality materials that can withstand harsh conditions typically found in industrial settings. Additionally, they incorporate safety features such as over-temperature protection and robust mounting brackets, ensuring peace of mind during operation.

Another important characteristic of the CGTH series is their efficiency. By minimizing energy waste and targeting heat output precisely, these heaters can significantly lower energy costs, making them not only environmentally friendly but also economically advantageous for businesses.

In summary, the Roberts Gordon CGTH-50, CGTH-40, and CGTH-30 infrared heaters stand out for their innovative technology, energy efficiency, and reliability. Whether for large commercial spaces or industrial environments, these heating solutions are designed to provide the comfort and performance required for any operation. With their robust features and customizable options, they remain a top choice for effective heating solutions in diverse settings.