York BQ 036, BQ 060, BQ 048 warranty Technical Guide Single Package Heat Pump Units, Description

Page 1

®

TECHNICAL GUIDE

SINGLE PACKAGE HEAT PUMP UNITS

BQ 036, 048 & 060

3, 4 & 5 NOMINAL TONS

10.0 SEER

036-21508-005-A-0305

DESCRIPTION

YORK Sunline 2000™ heat pumps are convertible single package units with a common cabinet and a common roof curb for the 3, 4 and 5 ton sizes. The units were designed for light commercial and commercial applications. They can eas- ily be installed on a roof curb, slab, roof jack or frame.

All units include:

Powder Paint finish that meets ASTM-B-117 1000 hour salt spray standards

Permanently lubricated motors

Bottom or side air discharge configuration capability (field convertible)

Manufactured under the quality standards of ISO9001

SimplicityTM Control Board

Copper tube/aluminum fin coils

Easy access to all components

Rigging holes in base rails for lifting

Fork lift slots on three sides

Single point power connection

Complete factory package - tested, charged and wired

CSA agency listing on all units

WARRANTY

Factory Limited Parts Warranty

One-year parts warranty

A Five-year parts warranty on the compressor and electric heat elements.

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

Image 1
Contents Description Technical Guide Single Package Heat Pump UnitsTable of Contents 718 Product Nomenclature Johnson UNT Controller, DFS, APS, SS Drain Pan Technicoat Condenser Coil & Dirty Filter Switch Hinged Filter Door & Toolless Access Cabinet 036-21508-005-A-0305 Novar ETC-3 Controller, DFS, APS, SS Drain Pan Hinged Filter Door & Toolless Access Cabinet Features Unit Cutaway FACTORY-INSTALLED OptionsFIELD-INSTALLED Accessories 036-21508-005-A-0305 Capacity Ratings Sound Power RATING1BQ036 Cooling Capacities 3 TON BQ048 Cooling Capacities 4 TON BQ060 Cooling Capacities 5 TON BQ Heating Capacities CFM RET. AIR F CAP Outdoor AIR TEMPERATURE, F 72% RH036-21508-005-A-0305 036-21508-005-A-0305 036-21508-005-A-0305 MED Belt Drive Blower Motor and Drive DataElectric Heater CFM Limitations Static ResistancesRLA LRA Voltage Motor Outlet Brkr 036-21508-005-A-0305 036-21508-005-A-0305 036-21508-005-A-0305 036-21508-005-A-0305 036-21508-005-A-0305 Electric Heat Correction Factors Physical DataVoltage LIMITATIONS1 Typical Control Wiring Typical Power WiringUnit Dimensions 3 5 TON Heat Pump Front View Unit with Fixed Outdoor AIR/MOTORIZED Damper Rainhood Minimum Clearances DISCONNECT/BLOWER Access Location Utilities EntryTypical Applications Operating Weights LBS BQ 6 Point Loads Weight DistributionCenter of Gravity General Guide SpecificationsDescription Indoor Evaporator FAN Assembly Manual Outdoor AIR Damper BAS Controls SImplicity INTELLI-Comfort 036-21508-005-A-0305