FEATURES
All models are available with a wide variety of factory- mounted options such as electric heaters, phase monitor, convenience outlet, dirty filter switch, disconnect switch, smoke detectors, and coil guards to make them suitable for almost every application.
All units are
All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. For bottom duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizon- tal duct, remove the supply and return air panels on the rear of the unit.
All models are available with these “factory mounted” outdoor air damper options:
•Single enthalpy economizer
•Motorized outdoor air damper
Supply air blowers are equipped with either a direct drive or a belt drive that can be adjusted to meet the exact require- ments of the job.
All compressors are equipped with internal pressure relief. Every refrigerant circuit includes a liquid line
•Simplicity™ Controls - Simplicity™ control boards have standardized a number of features previously available only as options or by utilizing additional controls.
•Low Ambient - An integrated
•
•Fan Delays - Fan on and fan off delays are fully pro- grammable and are independent of one another. All units are programmed with default values based upon their configuration of cooling and heat.
•Safety Monitoring - The control board monitors the high and
•Nuisance Trip Protection- To prevent nuisance trouble calls, the control board uses a “three strikes, you’re out” philosophy. The high and
•On Board Diagnostics - Each alarm will energize a trouble light on the thermostat, if so equipped, and flash an alarm code on the control board LED. Each high and
All units have long lasting powder paint cabinets with 750 hour salt spray test approval under
All models are CSA listed.
•Warranty - All models include a
•Electric Heat Operation - All electric heat models are wired for a single power source and include a bank of nickel chromium elements mounted at the discharge of the supply air blower to provide a high velocity and uni- form distribution of air across the heating elements. Every element is fully protected against excessive tem- perature by thermal limit switches.
The power supply wiring can be routed into the control box through a threaded pipe connection (field supplied) in the base pan of the unit or through a knockout in the wiring panel on the side of the unit.
•BAS Controls - York’s Sunline™ series units offer fac- tory mounted BAS controls such as SImplicity™