B.Shall have internal isolation and sound muffling to minimize vibration and noise, and be externally iso- lated on a dedicated, independent mounting.

2.Coils:

A.Evaporator and condenser coils shall have alumi- num plate fins mechanically bonded to seamless internally-enhanced copper tubes with all joints brazed.

B.Evaporator and Condenser coils shall be of the direct expansion, draw-thru design.

3.Refrigerant Circuit and Refrigerant Safety Compo- nents shall include:

A.Independent thermal expansion devices (TXV).

B.Solid-core filter dryer to eliminate any foreign matter.

C.Accessible service gage connections on both suc- tion and discharge lines to charge, evacuate, and measure refrigerant pressure during any necessary servicing or troubleshooting, without losing charge and without disrupting condenser or evaporator air flow.

D.The refrigeration system shall provide at least 10∞F of liquid sub-cooling at design conditions.

E.Unit shall have a suction line accumulator and auto- matic reversing valve.

4.Unit Controls:

A.Unit shall contain a large, low voltage Terminal Board for easy connection of field low voltage wir- ing.

B.Controls shall be mounted in a large control box with tilt-out, hinged access door, allowing easy access for trouble shooting and maintenance without affect- ing the normal system operation pressures.

C.Unit shall contain a reliable demand defrost control to provide defrost. The defrost control shall also have an ìXî terminal to provide a 24 volt signal for

036-21528-001-A-0303

room thermostat ìLEDî indication of unit lockout. Plus a built in 5 minute anti-short cycle protection.

D.Unit shall have large, easily removable panels, cov- ering electrical controls and compressor, allowing easy access for any maintenance or servicing.

ELECTRIC HEATING SECTION

1.An electric heating section, with nickel chromium elements, shall be provided in a range of 5 thru 25 KW.

2.The heating section shall have an automatic reset primary limit control to prevent the heating element system from operating at an excessive tempera- ture.

3.The heating section assembly shall slide out of the unit for easy maintenance and service.

4.Units with electric heating sections shall be wired for a single point power supply, with branch circuit fusing (where required).

UNIT OPERATING CHARACTERISTICS

1.Unit shall be capable of starting and running at 125∞F outdoor temperature, exceeding maximum load criteria of ARI Standard 210/240.

2.The compressor, with standard controls, shall be capable of operation down to 45∞F outdoor tem- perature. Accessory low ambient kit shall be avail- able for operation to 0∞F.

ELECTRICAL REQUIREMENTS

All unit power wiring shall enter unit cabinet at a single factory provided location and be capable of side or bot- tom entry. This will minimize roof penetrations and avoid unit field modifications. Separate side and bot- tom openings shall be provided for the control wiring.

26

Unitary Products Group

Image 26
Contents On Site Flexibility Lower Installation CostOperating Efficiency Utility Connections Made EasyDurable Finish Condensate PANCondensate Drain Full Perimeter Base RailsEasy Service Access LOW MaintenanceSecured Service Access Ports Replacement PartsRectangle to Round Adapters Wall Thermostat Transformer KIT Single Phase onlyTable of Contents Roof CurbsHSPF1 RATING2 MBH COP Single Phase Three PhasePhysical Data Nominal Capacity KW BHP MBH Seer EEROutdoor Coil WB ∞F Temperature of AIR on Indoor Coil Temperature AIR onCooling Capacities 2 TON BHP024 Cooling Capacities 2-1/2 TON BHP030 Outdoor CoilCooling Capacities 3 TON BHP036 Cooling Capacities 3-1/2 TON BHP042 Cooling Capacities 4 TON BHP048 Heating Capacities 2-1/2 TON BHP030 CFM Return CAP1 Outdoor AIR TEMPERATURE, ∞F 72% RHHeating Capacities 2 TON BHP024 Heating Capacities 3 TON BHP036 Heating Capacities 3-1/2 TON BHP042Heating Capacities 4 TON BHP048 Additional Static Resistance RESISTANCE, IWG Description CFMField Wiring Diagram Electrical Data Basic Unit Electrical Data 13 Seer Heat Pump / Electric Heat RLA LRAModel BHP B1HP Shipping Operating Corner Weights Unit SizeApplication Data Unit Dimensions Typical Applications Roof Curb Dimensions Typical Wiring Diagram 208/230-1-60 Power Supply Typical Wiring Diagram 230-3-60 Power Supply Typical Wiring Diagram 460-3-60 Power Supply General Description Indoor Supply FAN AssemblyOutdoor FAN Assembly Unit CabinetElectrical Requirements Unit Operating CharacteristicsElectric Heating Section 036-21528-001-A-0303 036-21528-001-A-0303

B1HP024 THRU 048 specifications

The York B1HP024 THRU 048 is a line of high-efficiency ducted split-system air conditioning units, designed to deliver optimal performance for residential and commercial spaces. These models are known for their advanced engineering and effective cooling capabilities, making them a popular choice among HVAC professionals.

One of the standout features of the York B1HP024 THRU 048 series is its energy efficiency. With SEER (Seasonal Energy Efficiency Ratio) ratings that exceed industry standards, these units help reduce energy consumption and lower utility bills. This efficiency is achieved through the use of modern compressor technology and an intelligent control system that adjusts cooling output based on real-time demand.

Another key characteristic of the York B1HP024 THRU 048 series is its use of inverter-driven compressors. This technology allows the units to adjust their speed dynamically, providing precise cooling without the frequent on-off cycling typical of traditional systems. As a result, users experience a quieter operation and improved comfort levels in their living or working spaces.

The design of these units emphasizes ease of installation and maintenance. The compact form factor and lightweight construction facilitate a smoother installation process, while service-friendly components make routine maintenance straightforward. This is particularly beneficial for technicians, as it reduces downtime and improves the reliability of the system.

In terms of comfort features, the York B1HP024 THRU 048 line is equipped with advanced filtration systems that enhance indoor air quality. These filters capture dust, allergens, and other airborne particles, creating a healthier environment for occupants. Additionally, some models come with smart technology integration, allowing users to control their HVAC system remotely via smartphones or smart home systems.

Durability is another hallmark of the York B1HP024 THRU 048 series. Constructed with high-quality materials and components that resist wear and tear, these units are built to last. Furthermore, they are designed to operate effectively in various environmental conditions, ensuring reliable performance year-round.