York B1HP024 THRU 048 manual General Description, Unit Cabinet, Indoor Supply FAN Assembly

Page 25

036-21528-001-A-0303

MECHANICAL SPECIFICATIONS

GENERAL DESCRIPTION

Units shall be factory-assembled, single packaged, Heat Pumps, designed for outdoor mounted installa- tion. Units shall have minimum SEER ratings of 13.0. They shall have built in, equal size, field convertible duct connections for down discharge supply/return or horizontal discharge supply/return.

The units shall be factory wired, piped, charged with R- 22 refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded.

All units shall be manufactured in a facility certified to ISO 9001 standards, and the cooling performance shall be rated in accordance with DOE and ARI test proce- dures. Units shall be classified to UL 1995/CAN/CSA No. 236-M90 conditions.

UNIT CABINET

1.Unit cabinet shall be constructed of G90 galva- nized steel, with exterior surfaces coated with a non-chalking, powered paint finish, certified at 750 hours salt spray test per ASTM-B117 standards.

2.The unit top shall be a single piece ìWater Shedî design, with drip edges and no-seam corners to provide optimum water integrity.

3.Unit shall have a rigidly mounted condenser coil guard to provide protection from objects and per- sonnel after installation.

4.Indoor blower section shall be insulated with up to 3/4î thick, aluminum, foil faced insulation, fastened to prevent insulation from entering the air stream.

5.Cabinet panels shall be ìlargeî size, easily remov- able for servicing and maintenance, with built-in lift handles.

6.Unit shall be built on a formed, ìSuper-Structureî design base pan, with embossments at critical points to add strength, rigidity and aid in minimizing sound.

7.Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rig- ging, fork truck access and proper sealing on roof curb applications. Base rails shall be removable, when required, to lower unit height.

8.Filters shall be furnished and be accessible through a removable access door, sealed air tight. (Single phase models - accessory kit available. Three phase models - standard from factory.)

9.Units vertical discharge and return duct configura- tion shall be designed to fit between standard 24î O.C. beams without modification to building struc- ture, duct work and base unit.

10.Condensate pan shall be internally sloped and conform to ASHARE 62-89 self-draining standards, with " NPTI copper, ridged mount connection.

INDOOR (SUPPLY) FAN ASSEMBLY

1.Fan shall be direct drive, constant CFM, ECM design. Job site selected (BHP) brake horse power shall not exceed the motors nameplate horse power rating.

2.Fan wheel shall be double-inlet type with forward- curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume.

3.Bearings shall be sealed and permanently lubri- cated for longer life and no maintenance.

4.Fan assembly shall be ìSlip Trackî (slide-out) design for easy removal and cleaning.

OUTDOOR FAN ASSEMBLY

1.The outdoor fan shall be of the direct-driven propel- ler type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider bracket and shall be statically balanced for smooth operation.

2.The outdoor fan motor shall be totally enclosed with permanently lubricated bearings and internally protected against overload conditions.

REFRIGERANT COMPONENTS

1.Compressors:

A.Shall be fully hermetic type, direct drive, internally protected with internal high-pressure relief and over temperature protection. The hermetic motor shall be suction gas cooled and have a voltage range of + or - 10% of the unit nameplate voltage.

Unitary Products Group

25

Image 25
Contents Operating Efficiency Lower Installation CostOn Site Flexibility Utility Connections Made EasyCondensate Drain Condensate PANDurable Finish Full Perimeter Base RailsSecured Service Access Ports LOW MaintenanceEasy Service Access Replacement PartsTable of Contents Transformer KIT Single Phase onlyRectangle to Round Adapters Wall Thermostat Roof CurbsPhysical Data MBH COP Single Phase Three PhaseHSPF1 RATING2 Nominal Capacity KW BHP MBH Seer EERCooling Capacities 2 TON BHP024 Temperature of AIR on Indoor Coil Temperature AIR onOutdoor Coil WB ∞F Outdoor Coil Cooling Capacities 2-1/2 TON BHP030Cooling Capacities 3 TON BHP036 Cooling Capacities 3-1/2 TON BHP042 Cooling Capacities 4 TON BHP048 Heating Capacities 2 TON BHP024 CFM Return CAP1 Outdoor AIR TEMPERATURE, ∞F 72% RHHeating Capacities 2-1/2 TON BHP030 Heating Capacities 3-1/2 TON BHP042 Heating Capacities 3 TON BHP036Heating Capacities 4 TON BHP048 RESISTANCE, IWG Description CFM Additional Static ResistanceField Wiring Diagram Electrical Data Basic Unit RLA LRA Electrical Data 13 Seer Heat Pump / Electric HeatApplication Data B1HP Shipping Operating Corner Weights Unit SizeModel BHP Unit Dimensions Typical Applications Roof Curb Dimensions Typical Wiring Diagram 208/230-1-60 Power Supply Typical Wiring Diagram 230-3-60 Power Supply Typical Wiring Diagram 460-3-60 Power Supply Outdoor FAN Assembly Indoor Supply FAN AssemblyGeneral Description Unit CabinetElectric Heating Section Unit Operating CharacteristicsElectrical Requirements 036-21528-001-A-0303 036-21528-001-A-0303

B1HP024 THRU 048 specifications

The York B1HP024 THRU 048 is a line of high-efficiency ducted split-system air conditioning units, designed to deliver optimal performance for residential and commercial spaces. These models are known for their advanced engineering and effective cooling capabilities, making them a popular choice among HVAC professionals.

One of the standout features of the York B1HP024 THRU 048 series is its energy efficiency. With SEER (Seasonal Energy Efficiency Ratio) ratings that exceed industry standards, these units help reduce energy consumption and lower utility bills. This efficiency is achieved through the use of modern compressor technology and an intelligent control system that adjusts cooling output based on real-time demand.

Another key characteristic of the York B1HP024 THRU 048 series is its use of inverter-driven compressors. This technology allows the units to adjust their speed dynamically, providing precise cooling without the frequent on-off cycling typical of traditional systems. As a result, users experience a quieter operation and improved comfort levels in their living or working spaces.

The design of these units emphasizes ease of installation and maintenance. The compact form factor and lightweight construction facilitate a smoother installation process, while service-friendly components make routine maintenance straightforward. This is particularly beneficial for technicians, as it reduces downtime and improves the reliability of the system.

In terms of comfort features, the York B1HP024 THRU 048 line is equipped with advanced filtration systems that enhance indoor air quality. These filters capture dust, allergens, and other airborne particles, creating a healthier environment for occupants. Additionally, some models come with smart technology integration, allowing users to control their HVAC system remotely via smartphones or smart home systems.

Durability is another hallmark of the York B1HP024 THRU 048 series. Constructed with high-quality materials and components that resist wear and tear, these units are built to last. Furthermore, they are designed to operate effectively in various environmental conditions, ensuring reliable performance year-round.

In summary, the York B1HP024 THRU 048 units combine energy efficiency, advanced technology, user-friendly design, and durability, making them an excellent choice for those seeking reliable cooling solutions. Whether for home or business, these systems provide not only comfort but also peace of mind.