York B1HP024 THRU 048 manual Physical Data, HSPF1 RATING2, Nominal Capacity KW BHP MBH Seer EER

Page 5

036-21528-001-A-0303

BACK AND BOTTOM

RETURN AIR

AND SUPPLY AIR

DUCT OPENING

HIGH VOLTAGE

TERMINAL BLOCK

LOW VOLTAGE

TERMINAL BLOCK

LONG-LASTING

POWDER PAINT

FINISH

HIGH-EFFICIENCY

COMPRESSOR

RIGIDLY

MOUNTED

DIRECT DRIVE

CONDENSER

FAN MOTOR

HIGHLY EFFICIENT ENHANCED COPPER TUBE/ALUMINUM FIN INDOOR COIL

HIGHLY EFFICIENT

ENHANCED COPPER

TUBE/ALUMINUM FIN

OUTDOOR COIL

DECORATIVE

PROTECTIVE

COIL GUARD

ECM DIRECT DRIVE BLOWER MOTOR WITH SLIDE-OUT BLOWER ASSEMBLY

HEAVY GAUGE

REMOVABLE

BASE RAILS

FIGURE 1 - UNIT CUT AWAY

TABLE 1: RATINGS

MODEL

COOLING CAPACITY1

 

SOUND

NET HEATING CAPACITY

AVAILABLE ELECTRIC HEAT

 

80 / 67-95∞F

 

HSPF1

RATING2

@47∞F

@17∞F

NOMINAL CAPACITY KW

 

BHP

 

 

 

 

MBH

SEER

 

EER

 

(dbels)

MBH

COP

MBH

COP

SINGLE PHASE

THREE PHASE

024

24.4

13.0

 

11.3

7.6

79

21.8

3.40

11.0

2.00

5.0, 7.5, 10.0

N / A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

030

30.0

13.0

 

11.3

7.6

77

28.2

3.40

16.5

2.20

5.0, 7.5, 10.0, 15.0

10.0,

15.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036

35.5

13.0

 

11.3

7.6

77

32.0

3.30

18.9

2.20

5.0, 7.5, 10.0, 15.0

10.0,

15.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

042

42.0

13.0

 

11.3

7.6

83

42.0

3.40

23.0

2.20

10.0, 15.0

10.0,

15.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

048

47.0

13.0

 

11.3

7.6

82

45.0

3.30

25.8

2.20

10.0, 15.0, 20.0, 25.0

10.0, 15.0,

20.0, 25.0

1.Certified in accordance with the Uniary Small Equipment certification program, which is based on ARI Standard 210/240.

2.Rated in accordance with ARI Standard 270.

SEER =Seasonal Energy Efficiency Ratio - the total cooling output in BTU's during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.

COP = Coefficient of Performance - the total heating capacity provided by the refrigeration system, including circulating fan heat but excluding supple- mentary resistance (BGUís per hour) divided by the total electric input (watts) x 3.412.

TABLE 2: PHYSICAL DATA

 

MODELS

 

 

BHP

 

 

 

 

 

 

 

 

 

 

 

024

030

036

 

042

048

 

 

 

 

 

 

 

 

INDOOR

CENTRIFUGAL BLOWER (Dia. x Wd. in.)

10 X 8

10 X 8

11 x 10

 

11 x 10

11 X 10

BLOWER

FAN MOTOR HP (ECM)

1/2

1/2

3/4

 

3/4

3/4

 

 

 

 

 

 

 

 

INDOOR

ROWS DEEP

2

3

3

 

3

3

FINS PER INCH

15

13

15

 

16

16

COIL

 

FACE AREA (Sq. Ft.)

4.38

4.38

4.38

 

5.63

5.63

 

 

 

 

 

 

 

 

 

 

OUTDOOR

PROPELLER DIA. (in.)

22

22

22

 

22

22

FAN MOTOR HP

1/4

1/4

1/4

 

1/4

1/4

FAN

 

NOM. CFM TOTAL

1,800

1,800

2,400

 

2,400

3,000

 

 

 

 

 

 

 

 

 

 

OUTDOOR

ROWS DEEP

1

1

2

 

2

2

FINS PER INCH

20

20

20

 

20

20

COIL

 

FACE AREA (Sq. Ft.)

11.7

11.7

11.7

 

16.4

16.4

 

 

 

 

 

 

 

 

 

 

CHARGE

REFRIGERANT 22 (lbs./oz.)

5 / 5

5 / 15

8 / 4

 

9 / 14

12 / 0

 

 

 

 

 

 

 

 

FILTER

FACE AREA (Sq. Ft. / Qty. / Size)

 

4.28 / 2 / 14 x 22

 

 

 

 

 

 

 

 

 

 

COMPRESSOR

Hermetic Type, Qty. = 1

Reciprocating

Scroll

Scroll

 

Scroll

Scroll

 

 

 

 

 

 

 

 

Unitary Products Group

5

Image 5
Contents Operating Efficiency Lower Installation CostOn Site Flexibility Utility Connections Made EasyCondensate Drain Condensate PANDurable Finish Full Perimeter Base RailsSecured Service Access Ports LOW MaintenanceEasy Service Access Replacement PartsTable of Contents Transformer KIT Single Phase onlyRectangle to Round Adapters Wall Thermostat Roof CurbsPhysical Data MBH COP Single Phase Three PhaseHSPF1 RATING2 Nominal Capacity KW BHP MBH Seer EEROutdoor Coil WB ∞F Temperature of AIR on Indoor Coil Temperature AIR onCooling Capacities 2 TON BHP024 Outdoor Coil Cooling Capacities 2-1/2 TON BHP030Cooling Capacities 3 TON BHP036 Cooling Capacities 3-1/2 TON BHP042 Cooling Capacities 4 TON BHP048 Heating Capacities 2-1/2 TON BHP030 CFM Return CAP1 Outdoor AIR TEMPERATURE, ∞F 72% RHHeating Capacities 2 TON BHP024 Heating Capacities 3-1/2 TON BHP042 Heating Capacities 3 TON BHP036Heating Capacities 4 TON BHP048 RESISTANCE, IWG Description CFM Additional Static ResistanceField Wiring Diagram Electrical Data Basic Unit RLA LRA Electrical Data 13 Seer Heat Pump / Electric HeatModel BHP B1HP Shipping Operating Corner Weights Unit SizeApplication Data Unit Dimensions Typical Applications Roof Curb Dimensions Typical Wiring Diagram 208/230-1-60 Power Supply Typical Wiring Diagram 230-3-60 Power Supply Typical Wiring Diagram 460-3-60 Power Supply Outdoor FAN Assembly Indoor Supply FAN AssemblyGeneral Description Unit CabinetElectrical Requirements Unit Operating CharacteristicsElectric Heating Section 036-21528-001-A-0303 036-21528-001-A-0303

B1HP024 THRU 048 specifications

The York B1HP024 THRU 048 is a line of high-efficiency ducted split-system air conditioning units, designed to deliver optimal performance for residential and commercial spaces. These models are known for their advanced engineering and effective cooling capabilities, making them a popular choice among HVAC professionals.

One of the standout features of the York B1HP024 THRU 048 series is its energy efficiency. With SEER (Seasonal Energy Efficiency Ratio) ratings that exceed industry standards, these units help reduce energy consumption and lower utility bills. This efficiency is achieved through the use of modern compressor technology and an intelligent control system that adjusts cooling output based on real-time demand.

Another key characteristic of the York B1HP024 THRU 048 series is its use of inverter-driven compressors. This technology allows the units to adjust their speed dynamically, providing precise cooling without the frequent on-off cycling typical of traditional systems. As a result, users experience a quieter operation and improved comfort levels in their living or working spaces.

The design of these units emphasizes ease of installation and maintenance. The compact form factor and lightweight construction facilitate a smoother installation process, while service-friendly components make routine maintenance straightforward. This is particularly beneficial for technicians, as it reduces downtime and improves the reliability of the system.

In terms of comfort features, the York B1HP024 THRU 048 line is equipped with advanced filtration systems that enhance indoor air quality. These filters capture dust, allergens, and other airborne particles, creating a healthier environment for occupants. Additionally, some models come with smart technology integration, allowing users to control their HVAC system remotely via smartphones or smart home systems.

Durability is another hallmark of the York B1HP024 THRU 048 series. Constructed with high-quality materials and components that resist wear and tear, these units are built to last. Furthermore, they are designed to operate effectively in various environmental conditions, ensuring reliable performance year-round.

In summary, the York B1HP024 THRU 048 units combine energy efficiency, advanced technology, user-friendly design, and durability, making them an excellent choice for those seeking reliable cooling solutions. Whether for home or business, these systems provide not only comfort but also peace of mind.