York B1HP024 THRU 048 manual Cooling Capacities 3-1/2 TON BHP042

Page 9

036-21528-001-A-0303

TABLE 6: COOLING CAPACITIES - 3-1/2 TON (BHP042)

 

 

 

 

 

 

 

 

 

 

TEMPERATURE OF AIR ON INDOOR COIL

 

 

 

TEMPERATURE AIR ON

 

 

1300 CFM

 

 

1400 CFM

 

 

OUTDOOR COIL

 

 

 

WB ∞F

 

 

 

WB ∞F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

67

 

62

57

72

67

 

62

57

 

 

 

NET CAP. MBH

 

48.8

44.5

 

40.5

40.6

49.2

44.9

 

40.8

41.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER INPUT kW

 

3.37

3.32

 

3.21

3.20

3.43

3.38

 

3.27

3.26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

 

86

31.6

39.4

 

40.5

40.6

33.0

41.0

 

40.8

41.0

 

MBH

 

DryEntering F∞Bulb

 

83

27.8

35.6

 

40.1

40.5

28.9

36.9

 

40.8

41.0

 

 

 

 

 

 

 

 

85 ∞F

 

1

 

 

 

80

24.0

31.8

 

38.8

40.2

24.8

32.8

 

40.1

41.5

 

 

 

 

 

 

77

20.2

27.9

 

35.0

36.4

20.7

28.8

 

36.0

37.4

 

 

 

 

 

 

74

16.4

24.1

 

31.2

32.6

16.7

24.7

 

31.9

33.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71

#N/A

20.3

 

27.4

28.7

#N/A

20.6

 

27.9

29.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68

#N/A

16.5

 

23.5

24.9

#N/A

16.5

 

23.8

25.2

 

 

 

NET CAP. MBH

 

45.4

41.5

 

38.3

38.5

45.7

41.9

 

38.6

38.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER INPUT kW

 

3.67

3.66

 

3.54

3.54

3.72

3.71

 

3.60

3.60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

 

86

30.7

38.2

 

38.3

38.5

32.0

39.8

 

38.6

38.8

 

MBH

 

DryEntering F∞Bulb

 

83

26.9

34.4

 

38.1

38.3

27.9

35.7

 

38.6

38.8

 

 

 

 

 

 

 

 

95 ∞F

 

1

 

 

 

80

23.0

30.6

 

37.5

37.9

23.9

31.6

 

38.8

39.2

 

 

 

 

 

 

77

19.2

26.8

 

33.6

34.0

19.8

27.6

 

34.7

35.1

 

 

 

 

 

 

74

15.4

23.0

 

29.8

30.2

15.7

23.5

 

30.6

31.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71

#N/A

19.1

 

26.0

26.4

#N/A

19.4

 

26.5

26.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68

#N/A

15.3

 

22.2

22.6

#N/A

15.3

 

22.4

22.8

 

 

 

NET CAP. MBH

 

41.9

37.7

 

35.2

35.6

42.1

37.9

 

35.4

35.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER INPUT kW

 

4.01

3.98

 

3.89

3.88

4.06

4.03

 

3.94

3.93

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

 

86

28.1

34.5

 

35.2

35.6

29.4

35.8

 

35.4

35.7

 

MBH

 

DryEntering F∞Bulb

 

83

24.5

31.6

 

34.8

35.1

25.6

33.0

 

35.2

35.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

105 ∞F

 

1

 

 

 

80

21.0

28.1

 

33.7

33.8

21.8

29.1

 

34.9

35.1

 

 

 

 

 

 

77

17.4

24.6

 

30.1

30.3

18.0

25.3

 

31.1

31.2

 

 

 

 

 

 

74

13.9

21.0

 

26.6

26.7

14.1

21.5

 

27.3

27.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71

#N/A

17.5

 

23.0

23.2

#N/A

17.7

 

23.5

23.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68

#N/A

13.9

 

19.5

19.6

#N/A

13.9

 

19.7

19.8

 

 

 

NET CAP. MBH

 

38.7

34.2

 

32.4

32.9

38.8

34.3

 

32.5

33.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER INPUT kW

 

4.41

4.35

 

4.28

4.28

4.46

4.40

 

4.33

4.32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

 

86

26.8

32.5

 

32.4

32.9

28.1

33.4

 

32.5

33.0

 

MBH

 

DryEntering F∞Bulb

 

83

23.3

30.2

 

32.1

32.3

24.3

31.5

 

32.3

32.7

 

 

 

 

 

 

 

 

115 ∞F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

80

19.7

26.7

 

31.2

31.0

20.5

27.7

 

32.4

32.2

 

 

 

 

 

 

77

16.2

23.1

 

27.6

27.5

16.7

23.9

 

28.6

28.4

 

 

 

 

 

 

74

12.6

19.6

 

24.1

24.0

12.9

20.1

 

24.8

24.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71

#N/A

16.1

 

20.6

20.4

#N/A

16.3

 

20.9

20.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68

#N/A

12.5

 

17.0

16.9

#N/A

12.5

 

17.1

17.0

 

 

 

NET CAP. MBH

 

35.6

30.7

 

29.6

30.3

35.5

30.6

 

29.6

30.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER INPUT kW

 

4.81

4.73

 

4.68

4.67

4.85

4.77

 

4.72

4.71

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

 

86

25.5

30.4

 

29.6

30.3

26.8

31.0

 

29.6

30.2

 

MBH

 

DryEntering F∞Bulb

 

83

22.0

28.8

 

29.4

29.6

23.0

30.1

 

29.5

29.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

125 ∞F

 

1

 

 

 

80

18.5

25.3

 

28.7

28.3

19.2

26.3

 

29.8

29.4

 

 

 

 

 

 

77

14.9

21.7

 

25.1

24.8

15.4

22.5

 

26.0

25.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

74

11.4

18.2

 

21.6

21.2

11.6

18.6

 

22.2

21.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71

#N/A

14.6

 

18.1

17.7

#N/A

14.8

 

18.4

18.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68

#N/A

11.1

 

14.5

14.1

#N/A

11.0

 

14.6

14.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.These capacities are net capacities - indoor fan heat deducted.

ALL SENSIBLE CAPACITY

Unitary Products Group

9

Image 9
Contents Operating Efficiency Lower Installation CostOn Site Flexibility Utility Connections Made EasyCondensate Drain Condensate PANDurable Finish Full Perimeter Base RailsSecured Service Access Ports LOW MaintenanceEasy Service Access Replacement PartsTable of Contents Transformer KIT Single Phase onlyRectangle to Round Adapters Wall Thermostat Roof CurbsPhysical Data MBH COP Single Phase Three PhaseHSPF1 RATING2 Nominal Capacity KW BHP MBH Seer EERTemperature of AIR on Indoor Coil Temperature AIR on Cooling Capacities 2 TON BHP024Outdoor Coil WB ∞F Outdoor Coil Cooling Capacities 2-1/2 TON BHP030Cooling Capacities 3 TON BHP036 Cooling Capacities 3-1/2 TON BHP042 Cooling Capacities 4 TON BHP048 CFM Return CAP1 Outdoor AIR TEMPERATURE, ∞F 72% RH Heating Capacities 2 TON BHP024Heating Capacities 2-1/2 TON BHP030 Heating Capacities 3-1/2 TON BHP042 Heating Capacities 3 TON BHP036Heating Capacities 4 TON BHP048 RESISTANCE, IWG Description CFM Additional Static ResistanceField Wiring Diagram Electrical Data Basic Unit RLA LRA Electrical Data 13 Seer Heat Pump / Electric HeatB1HP Shipping Operating Corner Weights Unit Size Application DataModel BHP Unit Dimensions Typical Applications Roof Curb Dimensions Typical Wiring Diagram 208/230-1-60 Power Supply Typical Wiring Diagram 230-3-60 Power Supply Typical Wiring Diagram 460-3-60 Power Supply Outdoor FAN Assembly Indoor Supply FAN AssemblyGeneral Description Unit CabinetUnit Operating Characteristics Electric Heating SectionElectrical Requirements 036-21528-001-A-0303 036-21528-001-A-0303

B1HP024 THRU 048 specifications

The York B1HP024 THRU 048 is a line of high-efficiency ducted split-system air conditioning units, designed to deliver optimal performance for residential and commercial spaces. These models are known for their advanced engineering and effective cooling capabilities, making them a popular choice among HVAC professionals.

One of the standout features of the York B1HP024 THRU 048 series is its energy efficiency. With SEER (Seasonal Energy Efficiency Ratio) ratings that exceed industry standards, these units help reduce energy consumption and lower utility bills. This efficiency is achieved through the use of modern compressor technology and an intelligent control system that adjusts cooling output based on real-time demand.

Another key characteristic of the York B1HP024 THRU 048 series is its use of inverter-driven compressors. This technology allows the units to adjust their speed dynamically, providing precise cooling without the frequent on-off cycling typical of traditional systems. As a result, users experience a quieter operation and improved comfort levels in their living or working spaces.

The design of these units emphasizes ease of installation and maintenance. The compact form factor and lightweight construction facilitate a smoother installation process, while service-friendly components make routine maintenance straightforward. This is particularly beneficial for technicians, as it reduces downtime and improves the reliability of the system.

In terms of comfort features, the York B1HP024 THRU 048 line is equipped with advanced filtration systems that enhance indoor air quality. These filters capture dust, allergens, and other airborne particles, creating a healthier environment for occupants. Additionally, some models come with smart technology integration, allowing users to control their HVAC system remotely via smartphones or smart home systems.

Durability is another hallmark of the York B1HP024 THRU 048 series. Constructed with high-quality materials and components that resist wear and tear, these units are built to last. Furthermore, they are designed to operate effectively in various environmental conditions, ensuring reliable performance year-round.

In summary, the York B1HP024 THRU 048 units combine energy efficiency, advanced technology, user-friendly design, and durability, making them an excellent choice for those seeking reliable cooling solutions. Whether for home or business, these systems provide not only comfort but also peace of mind.