HP Smart Array (RAID) Host Bus Adapters manual Setmode

Page 20

Table 1 <controller> strings

<controller>

Meaning

<seg:bus:dev:func>

A controller having the PCI segment id, bus id, device id

 

and function id is addressed

all

Addresses all controllers in the system

<model>

Controllers of a particular type indicated by the <model>

 

string are addressed

SET_MODE

IMPORTANT: If you are using HBA mode, do not install any disk that has previously been a part of a RAID volume into the system.

Use set_mode to change the mode of the controller. If the controller is already in the required mode the following message appears:

The controller at <seg:bus:dev:func> is already in HBARAID mode

Syntax

saupdate set_mode <controller> <hbaraid> [-f]

<controller> can be any one of the strings listed in Table 1 (page 20).

An alert message about the possible data loss is displayed when a mode change command is issued. A confirmation is required before the actual mode change is made. This ensures that an unintentional change of mode does not happen.

The –findicates the user is aware of the changes that are being made, and no warning message or confirmation regarding the mode change is needed.

20 Installing, verifying, and configuring the controller

Image 20
Contents Abstract Page Contents Cable kits Controller overview As array acceleratorWindows installation Installation overviewConfigure an array. See Creating a logical drive HP-UX installation HP-UX installation prerequisites Downloading softwareInstalling software Verifying the installationInstalling, verifying, and configuring the controller Installing the controller hardwareConnecting and verifying external storage devices Connecting external storage devicesVerifying external disk enclosure connections Verifying tape device connections Fs0\cd \EFI\HP\TOOLS\IOCARDS\SmartArrayVerifying and updating controller firmware offline Verifying the controller firmwareDownloading the firmware update Updating the controller firmware Fs0\ cd \EFI\HP\TOOLS\IOCARDS\SmartArrayVerifying the firmware update Help Determining and setting the controller mode Error messagesSetmode Verifying and updating enclosure firmware offline Verifying the enclosure firmwareDownloading the enclosure firmware Saupdate Update segbusdevfuncenclindex firmwarefile Updating the enclosure firmwareHelp Updating tape device firmware Using Option ROM Configuration for Arrays OrcaAccessing Orca Entry for the Smart Array SAS controller Orca main menu appears Orca Main Menu Screen Creating a logical drive Deleting a logical driveUsing Option ROM Configuration for Arrays Orca Installing, verifying, and configuring the controller Troubleshooting Smart Array P411 controller board runtime LEDsPost messages Determining Smart Array P411 controller CPU activity levelSupport and other resources Support and other resources Grounding Electrostatic dischargeHandling parts Cable kits
Related manuals