Table 1 <controller> strings
<controller> | Meaning |
<seg:bus:dev:func> | A controller having the PCI segment id, bus id, device id |
| and function id is addressed |
all | Addresses all controllers in the system |
<model> | Controllers of a particular type indicated by the <model> |
| string are addressed |
SET_MODE
IMPORTANT: If you are using HBA mode, do not install any disk that has previously been a part of a RAID volume into the system.
Use set_mode to change the mode of the controller. If the controller is already in the required mode the following message appears:
The controller at <seg:bus:dev:func> is already in HBARAID mode
Syntax
saupdate set_mode <controller> <hbaraid> [-f]
<controller> can be any one of the strings listed in Table 1 (page 20).
An alert message about the possible data loss is displayed when a mode change command is issued. A confirmation is required before the actual mode change is made. This ensures that an unintentional change of mode does not happen.