HP Smart Array (RAID) Host Bus Adapters manual Post messages

Page 32

Table 3 Determining Smart Array P411 controller CPU activity level

DS7 (Gas Pedal) Status

DS8 (Idle Task) Status

Controller CPU activity level

Off

Flashing

0 to 25%

Flashing

Off

25 to 50%

On steadily

Off

50% to 75%

On steadily

On steadily

75% to 100%

NOTE: During server power on, each runtime LED illuminates randomly until POST completes.

POST messages

Smart Array Controllers provide diagnostic error messages to the server BIOS at reboot. Many of these POST messages are self-explanatory and suggest corrective actions for troubleshooting.

A full listing of the error codes that can be returned by HP Smart Array Controller Option ROM during POST is provided in the HP Smart Array SAS Controllers For Integrity Servers Support Guide. This document is available on the HP website at:

http://www.hp.com/go/smart-array-raid-docs

32 Troubleshooting

Image 32
Contents Abstract Page Contents Cable kits Controller overview As array acceleratorWindows installation Installation overviewConfigure an array. See Creating a logical drive HP-UX installation HP-UX installation prerequisites Downloading softwareInstalling software Verifying the installationInstalling, verifying, and configuring the controller Installing the controller hardwareConnecting and verifying external storage devices Connecting external storage devicesVerifying external disk enclosure connections Verifying tape device connections Fs0\cd \EFI\HP\TOOLS\IOCARDS\SmartArrayVerifying and updating controller firmware offline Verifying the controller firmwareDownloading the firmware update Updating the controller firmware Fs0\ cd \EFI\HP\TOOLS\IOCARDS\SmartArrayVerifying the firmware update Help Determining and setting the controller mode Error messagesSetmode Verifying and updating enclosure firmware offline Verifying the enclosure firmwareDownloading the enclosure firmware Saupdate Update segbusdevfuncenclindex firmwarefile Updating the enclosure firmwareHelp Updating tape device firmware Using Option ROM Configuration for Arrays OrcaAccessing Orca Entry for the Smart Array SAS controller Orca main menu appears Orca Main Menu Screen Creating a logical drive Deleting a logical driveUsing Option ROM Configuration for Arrays Orca Installing, verifying, and configuring the controller Troubleshooting Smart Array P411 controller board runtime LEDsPost messages Determining Smart Array P411 controller CPU activity levelSupport and other resources Support and other resources Grounding Electrostatic dischargeHandling parts Cable kits