OPERATING INSTRUCTIONS
WARNING
Wait 30 seconds before readjusting the heater when the control has been turned down to a lower setting.
MATCH LIGHTING INSTRUCTIONS
If the pilot will not light using the piezo ignitor, you can light the pilot with a match. First, locate the pilot. The pilot is located between the burner tube on the right end (facing the unit), inside the firebox. To light pilot with a match, move the gas control (knob B, pg. 13) to the pilot position and hold down. Light match and place near pilot. Once pilot is lit, continue to hold the knob for about ten seconds. Then follow steps 9 thru 13 on page 13.
CHECKING FLAME APPEARANCE
Flames from the pilot and burner should be visually checked when the heater is installed. In addition, a periodic check of the flames should be made.
PILOT FLAME
The pilot flame should always be present when the heater is in operation and should just touch the top of the thermocouple tip (FIGURE 9).
If the pilot flame does not touch the thermocouple, then the main burner is unlikely to function reliably (FIG- URE 10).
FIGURE 9. Pilot Flame | FIGURE 10. Incorrect Shape of Pilot Flame |
| CLEANING / SERVICING |
Annual inspection and cleaning by your dealer or qualified service technician is recommended to prevent malfunction and/or sooting.
WARNING Turn off heater and allow to cool before cleaning.
Remove front screen, (see page 11). Carefully lift screen from locating stubs and set aside during cleaning. Refer to instructions on page 11 for installation of screen. Do not operate the unit with the screen removed.
Remove logs, handling carefully by holding gently at each end. Gloves are recommended to prevent skin irritation from ceramic. If the skin becomes irritated, wash gently with soap and water. Refer to manual for correct log placement.
Periodic Cleaning | 14 |