United States Stove B2045N, B2045L manual GAS Connection, Gas Connection

Page 9

GAS CONNECTION

NOTICE

CAUTION

A qualified gas appliance installer must connect the fireplace to the gas supply. Consult all local codes.

Usenewblackironorsteelpipeonly. Internallytinnedcoppertubingcanbeusedinsomeareas when permitted by local codes. Only use pipe of 1/2" or greater diameter to allow full gas volume to heater. Excessive pressure loss will occur if the pipe is too small.

A manual shutoff valve, union and plugged 1/8" NPT pressure tapping point must be installed upstream of the heater (FIGURE 4).

Asedimenttrapmustbeinstalledupstreamoftheheatertopreventmoistureandcontaminants from passing through the pipe to the heater controls and burners. Failure to do so could prevent the heater from operating reliably (FIGURE 4).

IMPORTANT: Loosen the pipe adapter on the flex tube before installing to the system piping.

FIGURE 5. Gas Connection

CHECK GAS TYPE: The gas supply must be the same as stated on heater's rating plate. If the gas supply is different, DO NOT INSTALL the heater. Contact your dealer for the correct model.

WARNING

Connectingdirectlytoanunregulatedpropane/LPGtankcancauseanexplosion.

9

Image 9
Contents Fuego Table of Contents Important Safety Information Features Product FeaturesContents SpecificationsItems Required for Installation Items Required for InstallationCodes Installation Mantel Clearances Gas Connection GAS ConnectionRear View of 2045 Vent-Free Gas Heater GAS Pressure CheckProper Installation Sequence LOG AssemblyRemoving Front Screen LOG PositioningFor Your Safety For Your Safety Read Before LightingOperating Instructions What to do if YOU Smell GASTurn OFF GAS to Appliance Lighting InstructionsMatch Lighting Instructions Cleaning / ServicingChecking Flame Appearance Pilot FlameFlames Flame AppearanceHeater Assembly Replacement Parts KEY Description QTY Parts List for Heater AssemblyBurner & LOG Assembly Parts List for Generator and LOG Assembly Observed Problem Possible Cause Remedy TroubleshootingTroubleshooting Optional Kits for the B2045 Optional Kits for the B2045 Wiring Diagram for Generator AssemblyStandard Wiring from Factory Wiring with the WSK60 Wall Switch KIT Page Limited Warranty Policy United States Stove Company HOW to Order Repair Parts or Options