FIGURE 7- IDENTIFICATION OF HARD AND SOFT SEAT PURGE VALVES
TROUBLESHOOTING THE AD-IS® EVERFLOW™ ASSEMBLY
Consult the service data sheet,
1.Excessive dryer purging in the loaded cycle.
•The purge valves in both dryers must have
•Excessive pressure (above 175 PSIG) in the compressor discharge line. Look for obstruction downstream of the
2.Air dryers do not purge.
•Insufficient air pressure in the secondary reservoir.
The EverFlow™ electronic module will not operate until air pressure in the secondary tank reaches 75 PSIG.
•The check valve in the
•The fuse is blown or the air dryer is not connected to the vehicle electrical system. Check electrical connection. If the fuse is blown replace the fuse with a higher amperage fuse. The fuse must be 15 amps or higher.
•Incorrect voltage. The air dryer voltage must match the vehicle voltage. Air dryers with a white heater connector are 12 volt DC and air dryers with a grey heater connector are 24 volt DC.
3.Air brake system will not build air.
• Compressor is undersized.
Some small capacity compressors will not develop sufficient air delivery at engine idle to allow proper operation of the
4.Water in downstream reservoirs.
•Dryers not purging. See step 2 - Air dryers do not purge.
•Desiccant cartridges need to be replaced.
•No pressure protection valve installed downstream of the air dryers. Refer to Figure 2.
BW2077 © 2007 Bendix Commercial Vehicle Systems LLC All rights reserved. 10/2007 Printed in U.S.A.