LOCK TABS
SPLASH
SHIELD
COVER
SPLASH
SHIELD
BRACKET
FIGURE 5 - SPLASH SHIELD BRACKET AND COVER - (EXPLODED VIEW)
Guidelines outlined on pages
This procedure does not require removal of the
1.Remove the line from governor and mark for easy reinstallation.
2.Remove the bolts attaching the governor to the
3.Remove the governor from the air dryer. Be aware that a short puff of trapped air may vent when the governor is removed. Retain the governor gasket for reassembly if a new governor gasket is not available. Remove and retain the
4.The spring/delivery check valve can now be removed. A second delivery check valve is located in the dryer without a governor. This check valve is located behind a hex head plug near the control line from the EverFlow™ module to the air dryer. Carefully remove the hex plug and follow the instructions that follow.
5.Remove and retain the
CLEANING & INSPECTION
Consult the service data sheet for the dryer used in your
1.Use a suitable solvent to clean all metal parts, and use a cotton swab to clean the bore (Note: Do not use abrasives or tools to clean the bore: any scratches caused may necessitate replacing the
2.Clean the
3.Inspect for physical damage to the bore and the check valve seat. If the bore is damaged (by scratches etc. that would prevent delivery check valve from seating), replace the
4.Inspect the delivery check valve,
5.Inspect all air line fittings for corrosion and replace as necessary.
8