CARE AND OPERATION

BLOWER SYSTEM

The Blower System consists of a ON/OFF rocker switch, a variable speed blower speed control switch (rheostat), a thermally activated switch (fan disc) and 2 axial blowers.

When starting a fire, leave the blower system off until the insert is thoroughly heated (approx. 30 minutes after start up).

The blowers can be operated in one of the following manners:

AUTO: Turn Rocker Switch to the OFF "o" position and the rheostat to the ON position (rotate rheostat dial clockwise until it clicks). When the insert warms up (110° F), the blower will automatically turn on (ad- just rheostat dial to the desired speed setting). When the insert cools down (90° F), the blowers will auto- matically turn off.

MANUAL: Turn Rocker Switch to the ON "-" position and adjust rheostat dial to the desired speed. The Blower will have to be manually turned off by rotating the rheostat dial counterclockwise until it clicks.

CAUTION: Burning the insert at a high burn rate for extended periods without running the blowers can cause excessive temperatures resulting in overfir- ing damage to the appliance. Excessive heat will cause the propellers on the blowers to melt. If this occurs, replace propellers and review these instruc- tions for proper operation (Propeller Part/Catalog #410-25-3. Some people prefer metal propellers, which are available through Grainger, stock #2C953. Be advised that these are noisier than standard plastic blades). Overfiring damage is not covered under the 5 year prorated warranty.

WARNING: This appliance is equipped with a blower system which has a flexible electrical power cord with a three-prong (grounding) plug for your protec- tion against shock hazard and should be plugged directly into a properly grounded three-prong recep- tacle per local codes or NEC, ANSI/NFPA 70-latest edition. Do not cut or remove the grounding prong from the power cord plug.

BLOWER SPECIFICATIONS: 115 Volt, 60 Hz, 2 axial blowers - .42 amps each, 125 CFM each. Blower sys- tem has a flexible electrical cord that must be electrically grounded per local codes or NEC, ANSI/NFPA 70-latest edition. Do not route the power cord under or in front of the appliance.

PAGE 15

Image 15
Contents Installation and Operation Manual Important Warnings Table of Contents Planning Your Installation Questions to ASK Local Building OfficialSmoke Detectors Alternative Floor Protection Materials Floor ProtectionVentilation Chimney InspectionClearances Draft RequirementsFactory Built Fireplaces Masonry FireplacesFireplace Chimney Maximum Size to Ensure Proper Draft Installation Fireplace Installation BV4000C Minimum Fireplace DimensionsCatalytic Temperature Probe Installation Steps Surround Assembly Positive Flue Connection for Masonry FIRE- Place Procuct Features and Controls Care and Operation HOW to Start and Maintain a Fire BREAK-IN PeriodRefueling Blower System Bypass Damper Control Maintenance Servicing Glass Catalyst ReplacementCleaning Blowers DOOR/GLASS Gasket and ASH Dump GasketCatalytic Combustor Troubleshooting Catalyst Substrate Catalyst PluggingCatalyst Deactivation Catalyst Substrate CrackingBTU Specifications Model BV4000CReplacement Parts List Model BV4000C Component Diagrams Model BV4000C Offset Adapter Cord Changeover KITGold Door KIT Safety Listing Label / EPA Label Service and Maintenance LOG West Taft Avenue Orange, CA

BV4000C specifications

Lennox International Inc has long been a leader in manufacturing high-efficiency heating, cooling, and refrigeration systems. Among its innovative product line is the Lennox BV4000C, a powerful and reliable commercial ventilation system designed to enhance indoor air quality and optimize energy efficiency. The BV4000C is engineered for use in various commercial settings, providing superior performance and durability.

One of the standout features of the BV4000C is its exceptional air capacity. Capable of delivering substantial airflow, it is ideally suited for larger commercial spaces that require effective ventilation. The unit is designed with advanced fan technology that ensures quiet operation while maintaining high efficiency. This reduces noise pollution in busy environments, making it a great choice for restaurants, offices, and retail establishments.

Energy efficiency is a top priority for the BV4000C, which is equipped with cutting-edge inverter-driven scroll compressors. These compressors automatically adjust their speed based on the demand for cooling or heating, leading to substantial energy savings. With its high SEER (Seasonal Energy Efficiency Ratio) rating, the BV4000C significantly lowers energy consumption without sacrificing comfort.

The BV4000C features innovative control technologies that streamline operation and improve user experience. The integrated smart thermostat allows for precise temperature control and can be easily programmed to meet the specific needs of any commercial setting. Additionally, it supports remote monitoring and control capabilities through mobile applications, ensuring that operators can manage their HVAC systems from anywhere.

Durability and reliability are critical for commercial HVAC systems, and the BV4000C does not disappoint. Constructed with high-quality materials, it is designed to withstand rigorous operational conditions and offers a long lifespan. The unit's robust build minimizes maintenance requirements, further enhancing its appeal for business owners seeking dependable solutions.

Safety is also a key consideration in the design of the BV4000C. It incorporates advanced safety features such as built-in surge protection, ensuring the unit operates safely even in variable electrical environments.

In summary, the Lennox BV4000C is a state-of-the-art commercial ventilation system that excels in efficiency, performance, and reliability. Its advanced technologies, versatile features, and commitment to energy savings make it an invaluable addition to any commercial property. Whether for cooling, heating, or ventilation, the BV4000C serves as an exemplary choice for businesses looking to enhance their indoor environment while reducing operational costs.