Lennox International Inc BV4000C operation manual Alternative Floor Protection Materials

Page 5

PLANNING YOUR INSTALLATION

FLOOR PROTECTION

This appliance requires a heat resistant non- combustible approved fireplace hearth or hearth exten- sion. If a hearth extension is used it must be a 3/8" (minimum) UL approved hearth pad or equivalent. If the floor protection is to be stone, tile, brick, etc., it must be mortared or grouted to form a continuous non- combustible surface (See Using Alternate Material As Floor Protector on this page).

This protected area must extend a minimum of 16" to the front of the fuel door opening and 8" beyond both sides of the fuel door opening

HEARTH PROTECTION

USING ALTERNATE MATERIAL AS A FLOOR PROTEC- TOR/HEARTH EXTENSION

The alternate material used as a hearth extension must be constructed of a durable noncombustible material having an equal or better insulating value (lower k value) of k = 1.28 BTU/IN FT2 HR ° F or a thermal resistance that equals or exceeds r = 78 HR ° F FT2 IN/BTU. With these values, determine the minimum thick- ness/material required using the formula and the table shown here (see chart - Alternative Floor Protection Materials).

Note: Any noncombustible material having a thickness of 1” whose k value is less than 1.28 or whose r value is more than .78 is acceptable. If the alternate material used has a higher k value or lower r value will require a greater thickness of the material used. In some cases, if the k value is less or the r value higher, a thinner mate- rial may be used.

Methods of determining floor protection equivalents

To determine the thickness required for any material when either the k or r values are known:

TM = Thickness of material in inches KM = K value of desired material TL = Minimum listed thickness

Example: Micore CV230 is to be used for the floor pro- tection. How thick must this material be?

The following formulas give the means of determining minimum thickness required of alternate materials.

Using the k formula:

Desired Thickness

k value of desire

Minimum thickness

of the alternate

=

material (per inch) x

of Listed

material

 

k value of listed

Material

 

 

material (per inch)

 

TM (inches) =

KM

x TL

 

1.28

 

 

 

 

 

TM (inches) =

0.43*

x 1”

 

 

1.28

 

 

Answer using k = 0.34 x 1” = 0.34 = 3/8” 3/8” thickness Micore will be required.

Using the r formula:

TM (inches) = 0.78 x TL rM

TM (inches) = 0.78 x 1” 2.33*

Answer using r = 0.34 x 1” = .034 = 3/8” 3/8” thickness Micore will be required.

At times it is important to know what combination of materials are acceptable for use as floor protection. The “R values” are used to determine acceptable combina- tions of materials because “R values” are additive where r and k values are not.

“R value” = 1 = r x thickness of material used k

ALTERNATIVE FLOOR PROTECTION MATERIALS

Listed

Values

Min. Thick

Material

k (per inch)

r (per inch)

 

TL

Millboard

1.28

0.78

 

1”

Alternative

Values

Min. Thick

Materials

k (per inch)

r (per inch)

 

TL

Wonderboard

1.92

0.56

1

1/2”

Common brick

5.00

0.20

3

7/8”

Cement mortar

5.00

0.20

3

7/8”

Ceramic tile

12.5

0.08

9

3/4”

Marble

11.0

0.09

8

5/8”

Micore CV230

0.43

2.33

3/8”

(U.S. Gypsum)

 

 

 

 

Ceraform 126

0.27

3.70

1/4”

(Johns-Manville)

 

 

 

 

Example: Given that the required “R value” for a suitable floor protector used must be equal to or greater than: “R” = r x TL = 0.78 x 1” = 0.78.

PAGE 5

Image 5
Contents Installation and Operation Manual Important Warnings Table of Contents Smoke Detectors Planning Your InstallationQuestions to ASK Local Building Official Alternative Floor Protection Materials Floor ProtectionClearances Chimney InspectionDraft Requirements VentilationFireplace Chimney Maximum Size to Ensure Proper Draft Factory Built FireplacesMasonry Fireplaces Catalytic Temperature Probe InstallationFireplace Installation BV4000C Minimum Fireplace Dimensions Installation Steps Surround Assembly Positive Flue Connection for Masonry FIRE- Place Procuct Features and Controls Care and Operation Refueling HOW to Start and Maintain a FireBREAK-IN Period Blower System Bypass Damper Control Maintenance Cleaning Blowers Catalyst ReplacementDOOR/GLASS Gasket and ASH Dump Gasket Servicing GlassCatalytic Combustor Troubleshooting Catalyst Deactivation Catalyst PluggingCatalyst Substrate Cracking Catalyst SubstrateBTU Specifications Model BV4000CReplacement Parts List Model BV4000C Component Diagrams Model BV4000C Gold Door KIT Offset AdapterCord Changeover KIT Safety Listing Label / EPA Label Service and Maintenance LOG West Taft Avenue Orange, CA

BV4000C specifications

Lennox International Inc has long been a leader in manufacturing high-efficiency heating, cooling, and refrigeration systems. Among its innovative product line is the Lennox BV4000C, a powerful and reliable commercial ventilation system designed to enhance indoor air quality and optimize energy efficiency. The BV4000C is engineered for use in various commercial settings, providing superior performance and durability.

One of the standout features of the BV4000C is its exceptional air capacity. Capable of delivering substantial airflow, it is ideally suited for larger commercial spaces that require effective ventilation. The unit is designed with advanced fan technology that ensures quiet operation while maintaining high efficiency. This reduces noise pollution in busy environments, making it a great choice for restaurants, offices, and retail establishments.

Energy efficiency is a top priority for the BV4000C, which is equipped with cutting-edge inverter-driven scroll compressors. These compressors automatically adjust their speed based on the demand for cooling or heating, leading to substantial energy savings. With its high SEER (Seasonal Energy Efficiency Ratio) rating, the BV4000C significantly lowers energy consumption without sacrificing comfort.

The BV4000C features innovative control technologies that streamline operation and improve user experience. The integrated smart thermostat allows for precise temperature control and can be easily programmed to meet the specific needs of any commercial setting. Additionally, it supports remote monitoring and control capabilities through mobile applications, ensuring that operators can manage their HVAC systems from anywhere.

Durability and reliability are critical for commercial HVAC systems, and the BV4000C does not disappoint. Constructed with high-quality materials, it is designed to withstand rigorous operational conditions and offers a long lifespan. The unit's robust build minimizes maintenance requirements, further enhancing its appeal for business owners seeking dependable solutions.

Safety is also a key consideration in the design of the BV4000C. It incorporates advanced safety features such as built-in surge protection, ensuring the unit operates safely even in variable electrical environments.

In summary, the Lennox BV4000C is a state-of-the-art commercial ventilation system that excels in efficiency, performance, and reliability. Its advanced technologies, versatile features, and commitment to energy savings make it an invaluable addition to any commercial property. Whether for cooling, heating, or ventilation, the BV4000C serves as an exemplary choice for businesses looking to enhance their indoor environment while reducing operational costs.