PLANNING YOUR INSTALLATION

CHIMNEY INSPECTION

The existing fireplace should be inspected by a local fire marshal or qualified installer for adequate serviceability prior to installing this appliance.

Factory built fireplace: If any portion of the chimney system shows signs of structural or mechanical weak- nesses, such as: cracks, leaky joints, corroded or warped surfaces. Look for obvious bulges in the lining, which may indicate the need to replace that section (use a bright flashlight. Any faulty portion must be re- paired or replaced prior to installing this appliance. Also, inspect the attic to see that the chimney has proper clearance to combustible framing members.

Masonry fireplace: The chimney should have no cracks, loose mortar, other signs of deterioration, or blockage. Any necessary repairs should be done by a qualified mason.

If the existing fireplace flue system is dirty or has some obstruction in it, clean it. A dirty chimney can cause your insert to smoke when refueling, and can result in a chim- ney fire. An oversized chimney may result in less than optimum performance. Installations into a large masonry chimney may require a liner to improve performance.

CLEARANCES

WARNING: It is very important that you observe the minimum clearances.

There are listed clearances for your fireplace insert which were determined in a laboratory testing and must be maintained.

Minimum Clearance to Combustibles

Stove top to mantel:

32"

Stove top to trim:

24"

Stove side to trim:

9"

Stove side to sidewall:

17"

DRAFT REQUIREMENTS

The appliance is merely one component of a larger sys- tem. The other equally important component is the vent- ing system. This is necessary for achieving the required flow of combustion air to the fire chamber and for safely removing unwanted combustion byproducts from the ap- pliance. If the venting system's design does not promote these ends, the system may not function properly. Poorly functioning venting systems may create performance problems as well as be a safety hazard (i.e. an oversized chimney may result in less than optimum performance. Installations into a large, masonry chimney may require a liner to improve performance). A draft test should read greater than .04' W.C. (inches water column) and less than .08" W.C.

VENTILATION

Ventilation is essential when using a solid burning appli- ance. The combustion process uses oxygen from inside the home and it may be necessary to open a window in a house that is well insulated.

PAGE 6

Image 6
Contents Installation and Operation Manual Important Warnings Table of Contents Planning Your Installation Questions to ASK Local Building OfficialSmoke Detectors Floor Protection Alternative Floor Protection MaterialsDraft Requirements Chimney InspectionClearances VentilationFactory Built Fireplaces Masonry FireplacesFireplace Chimney Maximum Size to Ensure Proper Draft Installation Fireplace Installation BV4000C Minimum Fireplace DimensionsCatalytic Temperature Probe Installation Steps Surround Assembly Positive Flue Connection for Masonry FIRE- Place Procuct Features and Controls Care and Operation HOW to Start and Maintain a Fire BREAK-IN PeriodRefueling Blower System Bypass Damper Control Maintenance DOOR/GLASS Gasket and ASH Dump Gasket Catalyst ReplacementCleaning Blowers Servicing GlassCatalytic Combustor Troubleshooting Catalyst Substrate Cracking Catalyst PluggingCatalyst Deactivation Catalyst SubstrateSpecifications Model BV4000C BTUReplacement Parts List Model BV4000C Component Diagrams Model BV4000C Offset Adapter Cord Changeover KITGold Door KIT Safety Listing Label / EPA Label Service and Maintenance LOG West Taft Avenue Orange, CA

BV4000C specifications

Lennox International Inc has long been a leader in manufacturing high-efficiency heating, cooling, and refrigeration systems. Among its innovative product line is the Lennox BV4000C, a powerful and reliable commercial ventilation system designed to enhance indoor air quality and optimize energy efficiency. The BV4000C is engineered for use in various commercial settings, providing superior performance and durability.

One of the standout features of the BV4000C is its exceptional air capacity. Capable of delivering substantial airflow, it is ideally suited for larger commercial spaces that require effective ventilation. The unit is designed with advanced fan technology that ensures quiet operation while maintaining high efficiency. This reduces noise pollution in busy environments, making it a great choice for restaurants, offices, and retail establishments.

Energy efficiency is a top priority for the BV4000C, which is equipped with cutting-edge inverter-driven scroll compressors. These compressors automatically adjust their speed based on the demand for cooling or heating, leading to substantial energy savings. With its high SEER (Seasonal Energy Efficiency Ratio) rating, the BV4000C significantly lowers energy consumption without sacrificing comfort.

The BV4000C features innovative control technologies that streamline operation and improve user experience. The integrated smart thermostat allows for precise temperature control and can be easily programmed to meet the specific needs of any commercial setting. Additionally, it supports remote monitoring and control capabilities through mobile applications, ensuring that operators can manage their HVAC systems from anywhere.

Durability and reliability are critical for commercial HVAC systems, and the BV4000C does not disappoint. Constructed with high-quality materials, it is designed to withstand rigorous operational conditions and offers a long lifespan. The unit's robust build minimizes maintenance requirements, further enhancing its appeal for business owners seeking dependable solutions.

Safety is also a key consideration in the design of the BV4000C. It incorporates advanced safety features such as built-in surge protection, ensuring the unit operates safely even in variable electrical environments.

In summary, the Lennox BV4000C is a state-of-the-art commercial ventilation system that excels in efficiency, performance, and reliability. Its advanced technologies, versatile features, and commitment to energy savings make it an invaluable addition to any commercial property. Whether for cooling, heating, or ventilation, the BV4000C serves as an exemplary choice for businesses looking to enhance their indoor environment while reducing operational costs.