Maytag HRE41240S, HRE11240S, HRE41282T manual Converting the Lower Element, Filling the Water Heater

Page 12

Converting the Lower Element

These instructions only cover the conversion of the convertible element, read this entire manual before attempting to install or operate the water heater. The water heater is factory set to operate at 3800 watts. The lower element can be converted to operate at 5500 watts. Refer to “The Convertible Lower Element” section.

The Upper Element is a conventional 3800 watt element which only operates at its rated wattage on 240 volts. (See rating plate on the water heater.

The lower Element of the water heater can be converted from operation at 3800 watts to 5500 watts on a 240 volt system.

If after reading these instructions and this manual, if you do not understand any portion, call Maytag Customer Service at 1-800-788-8899 for an authorized servicer.

FIGURE 10.

Filling the Water Heater

Never use this water heater unless it is completely full of water. To prevent damage to the tank and heating element, the tank must be filled with water. Water must flow from the hot water faucet before turning “ON” power.

To fill the water heater with water:

1.Close the water heater drain valve by turning the handle to the right (clockwise). The drain valve is located on the lower front of the water heater.

2.Open the cold water supply valve to the water heater.

NOTE: The cold water supply valve must be left open when the water heater is in use.

3.To insure complete filling of the tank, allow air to exit by opening the nearest hot water faucet. Allow water to run until a constant flow is obtained. This will let air out of the water heater and the piping.

4.Check all new water piping for leaks. Repair as needed.

Before making the conversion to 5500 watts, check the (1) power supply . . . must be 240 volts, (2) wiring . . . 10 gauge AWG @ Type TW, 60°C or equivalent, and (3) Circuit breakers or fusing . . .capable of 30 amp loading. Also, the installation must conform with this manual, local codes and electric utility rules. Failure to comply can result in DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

NOTE: Whether or not the element conversion is made the model rating plate must be marked. Using a hard point ink pen, check the appropriate block within the model rating plate, which is located adjacent to the lower access panel.

FIGURE 11.

12

Image 12
Contents Listed Save this Manualfor Future ReferenceSafe INSTALLATION, USE and Service General Safety Table of Contents Product Specifications Customer InformationAccessories and Tools Needed AccessoriesAdditional Tools Needed When Sweat Soldering ToolsInstallation Instructions Removing the Old Water HeaterTypical Installation Locating the New Water HeaterConvertible Lower Element Water Piping Valve and Pipe InsulationTemperature-Pressure Relief Valve Converting the Lower Element Filling the Water HeaterPage Wiring Page Wiring Diagrams Service and Maintenance Temperature RegulationTemperature Settings Thermostat AdjustmentsTemperature-Pressure Relief Valve Operation Anode Rod InspectionDraining Thermostat Removal/Replacement Element Cleaning/ReplacementPage Page Troubleshooting Drain Valve Washer ReplacementService Start Up ConditionsHigh Temperature Shut OFF System Operational ConditionsSmelly Water AIR in HOT Water Faucets Rumbling NoiseLeakage Checkpoints Not Enough or no HOT WaterWater is TOO HOT Repair Parts List MAYTAG/STATE Part Number Conversion KEY Maytag StateThis is a Repair Parts LIST, not a Packaging List Maytag Electric Water HeatersHRE41250T HRE11282T HRE41282T Full ONE Year Warranty