Operational Conditions

SMELLY WATER

In each glass-lined water heater there is installed one anode rod (see parts section) for corrosion protection of the tank. Certain water conditions will cause a reaction between this rod and the water. The most common complaint associated with the anode rod is one of a “rotten egg smell”. This odor is derived from hydrogen sulfide gas dissolved in the water. The smell is the result of four factors which must all be present for the odor to develop:

A.A concentration of sulfate in the supply water.

B.Little or no dissolved oxygen in the water.

C.A sulfate reducing bacteria within the water heater. (This harmless bacteria is non-toxic to humans.)

D.An excess of active hydrogen in the tank. This is caused by corrosion protective action of the anode.

Smelly water may be eliminated or reduced in some water heater models by replacing the anode rod with one of less active material, and then chlorinating the water heater tank and all hot water lines. Call Maytag Customer Service at 1-800-788-8899 for an authorized servicer for further information concerning an anode replacement kit #66001068 and this chlorination treatment.

If smelly water persists, after anode replacement and chlorination treatment, we can only suggest that continuous chlorination and filtering conditioning equipment be considered to eliminate the water problem.

Do not remove the anode leaving the tank unprotected. By doing so, all warranty on the water heater tank is voided.

“AIR” IN HOT WATER FAUCETS

RUMBLING NOISE

In some water areas, scale or mineral deposits will build up on your heating elements. This buildup will cause a rumbling noise. Follow “Element Cleaning/Replacement” instructions to clean and replace the elements.

HIGH TEMPERATURE SHUT OFF SYSTEM

The water heater has a high limit shut off system with a reset button located on the thermostat.

Follow the resetting instructions which refer to the high limit behind the access panel.

NOTE: If your water heater is connected to an “Off Peak” Clock, and uses the “3 wire lead” wiring diagram in the “Wiring Diagram” section, then the water heater will have a high limit on both the upper and lower thermostats. Follow the instructions to reset the high-limit behind the upper and lower access panels.

1.Before beginning, turn “OFF” electrical power supply to the water heater.

HYDROGEN GAS: Hydrogen gas can be produced in a hot water system that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable and explosive. To prevent the possibility of injury under these conditions, we recommend the hot water faucet be opened for several minutes at the kitchen sink before any electrical appliances which are connected to the hot water system are used (such as a dishwasher or washing machine). If hydrogen gas is present, there will probably be an unusual sound similar to air escaping through the pipe as the hot water faucet is opened. There must be no smoking or open flame near the faucet at the time it is open.

FIGURE 43.

2.Remove the two screws securing the access panel and remove panel.

3.Remove the insulation cap with handle to expose the terminal cover.

4.Reset the high limit by pushing in the red button marked “RESET”.

FIGURE 44.

23

Image 23
Contents Save this Manualfor Future Reference ListedSafe INSTALLATION, USE and Service General Safety Table of Contents Customer Information Product SpecificationsTools Accessories and Tools NeededAccessories Additional Tools Needed When Sweat SolderingRemoving the Old Water Heater Installation InstructionsLocating the New Water Heater Typical InstallationConvertible Lower Element Valve and Pipe Insulation Water PipingTemperature-Pressure Relief Valve Filling the Water Heater Converting the Lower ElementPage Wiring Page Wiring Diagrams Thermostat Adjustments Service and MaintenanceTemperature Regulation Temperature SettingsDraining Temperature-Pressure Relief Valve OperationAnode Rod Inspection Element Cleaning/Replacement Thermostat Removal/ReplacementPage Page Start Up Conditions TroubleshootingDrain Valve Washer Replacement ServiceAIR in HOT Water Faucets Rumbling Noise High Temperature Shut OFF SystemOperational Conditions Smelly WaterWater is TOO HOT Leakage CheckpointsNot Enough or no HOT Water MAYTAG/STATE Part Number Conversion KEY Maytag State Repair Parts ListMaytag Electric Water Heaters This is a Repair Parts LIST, not a Packaging ListHRE41250T HRE11282T HRE41282T Full ONE Year Warranty