Maytag HRE41282T, HRE11240S, HRE41250S, HRE41250T, HRE41240S, HRE11282T Convertible Lower Element

Page 9

supply or hardware stores. Follow manufacturers instructions for installation of the valves. Before changing the factory setting on the thermostat, read the “Temperature Regulation” section in this manual.

FIGURE 8

WATER HEATERS EVENTUALLY LEAK: Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak, the flow of water will not cause damage to the structure. For this reason, it is not advisable to install the water heater in an attic or upper floor. When such locations cannot be avoided, a suitable drain pan should be installed under the water heater. Drain pans are available at your local hardware store. Such a drain pan must have a minimum length and width of at least 1 3/4 inches greater than the water heater dimensions and must be piped to an adequate drain.

INSTALLATION IN RESIDENTIAL GARAGES: The water heater must be located and/or protected so it is not subject to physical damage by a moving vehicle.

The location selection must provide adequate clearances for servicing and proper operation of the water heater.

The Convertible Lower Element

The Upper Element, is a conventional 3800 watt element which only operates at its rated wattage on 240 volts. (See rating plate on the water heater).

The Lower Element of the water heater can be converted from operation at 3800 watts to 5500 watts on a 240 volt system.

Read and follow water heater warnings and instructions. If after reading these instructions in this manual, you do not understand any portion, call Maytag Customer Service at 1-800-788-8899 for an authorized sevicer.

Before making the conversion to 5500 watts, check the (1) power supply . . . must be 240 volts, (2) wiring . . . 10 gauge AWG @ Type TW, 60°C or equivalent, and (3) Circuit breakers or fusing . . .capable of 30 amp loading. Also, the installation must conform with this manual, local codes and electric utility rules. Failure to comply can result in DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

NOTE: Whether or not the element conversion is made the model rating plate must be marked. Using a hard point ink pen, check the appropriate block within the model rating plate, which is located adjacent to the lower access panel.

9

Image 9
Contents Save this Manualfor Future Reference ListedSafe INSTALLATION, USE and Service General Safety Table of Contents Customer Information Product SpecificationsAccessories Accessories and Tools NeededAdditional Tools Needed When Sweat Soldering ToolsRemoving the Old Water Heater Installation InstructionsLocating the New Water Heater Typical InstallationConvertible Lower Element Valve and Pipe Insulation Water PipingTemperature-Pressure Relief Valve Filling the Water Heater Converting the Lower ElementPage Wiring Page Wiring Diagrams Temperature Regulation Service and MaintenanceTemperature Settings Thermostat AdjustmentsTemperature-Pressure Relief Valve Operation Anode Rod InspectionDraining Element Cleaning/Replacement Thermostat Removal/ReplacementPage Page Drain Valve Washer Replacement TroubleshootingService Start Up ConditionsOperational Conditions High Temperature Shut OFF SystemSmelly Water AIR in HOT Water Faucets Rumbling NoiseLeakage Checkpoints Not Enough or no HOT WaterWater is TOO HOT MAYTAG/STATE Part Number Conversion KEY Maytag State Repair Parts ListMaytag Electric Water Heaters This is a Repair Parts LIST, not a Packaging ListHRE41250T HRE11282T HRE41282T Full ONE Year Warranty