Installation

Grounding

The equipment must be grounded. Grounding reduces the risk of static and electric shock by pro- viding an escape wire for the electrical current due to static build up or in the event of a short circuit.

Pump: See FIG. 4. Verify that the ground screw (GS) is attached and tightened securely to the air motor. Con- nect the other end of the ground wire (S) to a true earth ground.

S

GS

ti12914a

FIG. 4. Ground the Pump.

Air and fluid hoses: Static electricity may build up when fluids flow through pumps, hoses, and sprayers. At least one hose must be electrically conductive, with a maximum of 500 ft. (150 m) combined hose length to ensure grounding continuity. Check electrical resistance of hose. If total resistance to ground exceeds 25 meg- ohms, replace hose immediately.

Air compressor: follow manufacturer’s recommenda- tions.

Spray gun / Dispense valve: Ground the spray gun through connection to a Graco-approved grounded fluid hose.

Fluid supply container: follow local code.

Object being sprayed: follow local code.

Solvent pails used when flushing: follow local code. Use only conductive metal pails, placed on a grounded surface. Do not place the pail on a nonconductive sur- face, such as paper or cardboard, which interrupts grounding continuity.

To maintain grounding continuity when flushing or relieving pressure: hold metal part of the spray gun/dispense valve firmly to the side of a grounded metal pail, then trigger the gun/valve.

Mount the Pump

Mount the pump directly to the wall (order Wall Mounting Kit, page 24) or to a Graco cart (order Cart Mounting Kit 24E879). Pump dimensions are shown on page 30.

Wall-Mounted Pumps

1.Be sure the wall can support the weight of the pump, bracket, hoses and accessories, as well as the stress caused during operation.

2.Position the wall bracket about 1.2-1.5 m (4-5 ft) above the floor. For ease of operation and service, make sure the pump air inlet, fluid inlet, and fluid outlet ports are easily accessible.

3.Using the wall bracket as a template, drill 10 mm (0.4 in.) mounting holes in the wall. Wall mounting dimensions are shown on page 31.

4.Attach the bracket to the wall. Use 9 mm (3/8 in.) screws that are long enough to keep the pump from vibrating during operation.

NOTE: Be sure the pump is level.

Cart-Mounted Pumps

Kit 24E885 is available if you plan to bolt your cart to the floor. It includes two spacers that keep the legs stable. Bolts not included.

Air and Fluid Hoses

Be sure all air hoses (N) and fluid hoses (M) are prop- erly sized and pressure rated for your system. See FIG. 3. Use only electrically conductive fluid hoses.

12

312795E

Image 12
Contents Merkur Bellows Pump Assembly II 2 G c IIB T3 200CContents Related ManualsFire and Explosion Hazard Equipment Misuse Hazard Important Two-Component Material Information Models Smarts/Exhaust PackingsAir Displacement Working Pressure At 60 cpm Fluid Pump DataMotor Pump Fluid Inlet Outlet Air InletComponent Identification Component Identification KeyComponent Identification 312795E Installation General InformationPrepare the Operator Typical Cart-Mount Installation Key Prepare the SiteGrounding Mount the PumpAir and Fluid Hoses Wall-Mounted PumpsAccessories Air LineFluid Line Pressure Relief Procedure OperationFlush the Pump Before First Use Trigger LockPrime and Adjust the Pump Shutdown and Care of the PumpMaintenance Preventive Maintenance ScheduleFollow Pressure Relief Procedure, Tighten Threaded ConnectionsTroubleshooting Problem Cause SolutionDisconnect the Displacement Pump RepairPreparation Disconnect the PumpDisconnect the Air Motor Reconnect the Displacement Pump Reconnect the PumpReconnect the Air Motor Repair 312795E Parts Parts That Vary by Model Part No./DescriptionRepair Kits Wall Mounting KitsCart Mounting Kit 24E879 Overflow Chamber Kit 24E298Repair Kits 312795E Performance Charts Model B15Bxx Fluid Outlet Pressure psi MPa, barMin BarMPa PressureModel B25Bxx Fluid Cycles per MinutePump Dimensions ModelWall Bracket Mounting Dimensions Technical DataGraco Standard Warranty Graco Information