WARNING

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system com- ponent. See Technical Data in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS from distributor or retailer.

Do not leave the work area while equipment is energized or under pressure. Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufac- turer’s replacement parts only.

Do not alter or modify equipment.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

MOVING PARTS HAZARD

Moving parts can pinch, cut or amputate fingers and other body parts.

Keep clear of moving parts.

Do not operate equipment with protective guards or covers removed.

Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure and disconnect all power sources.

SUCTION HAZARD

Powerful suction could cause serious injury.

Never place hands near the pump fluid inlet when pump is operating or pressurized.

TOXIC FLUID OR FUMES HAZARD

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swal- lowed.

Read MSDSs to know the specific hazards of the fluids you are using.

Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.

Always wear chemically impermeable gloves when spraying, dispensing, or cleaning equipment.

PERSONAL PROTECTIVE EQUIPMENT

You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, hearing loss, inhalation of toxic fumes, and burns. This equipment includes but is not limited to:

Protective eyewear, and hearing protection.

Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.

4

312795E

Image 4
Contents Merkur Bellows Pump Assembly II 2 G c IIB T3 200CContents Related ManualsFire and Explosion Hazard Equipment Misuse Hazard Important Two-Component Material Information Models Smarts/Exhaust PackingsAir Displacement Working Pressure At 60 cpm Fluid Pump DataMotor Pump Fluid Inlet Outlet Air InletComponent Identification Component Identification KeyComponent Identification 312795E General Information InstallationPrepare the Operator Typical Cart-Mount Installation Key Prepare the SiteGrounding Mount the PumpAir and Fluid Hoses Wall-Mounted PumpsAir Line AccessoriesFluid Line Pressure Relief Procedure OperationFlush the Pump Before First Use Trigger LockPrime and Adjust the Pump Shutdown and Care of the PumpMaintenance Preventive Maintenance ScheduleFollow Pressure Relief Procedure, Tighten Threaded ConnectionsTroubleshooting Problem Cause SolutionDisconnect the Displacement Pump RepairPreparation Disconnect the PumpDisconnect the Air Motor Reconnect the Pump Reconnect the Displacement PumpReconnect the Air Motor Repair 312795E Parts Parts That Vary by Model Part No./DescriptionRepair Kits Wall Mounting KitsCart Mounting Kit 24E879 Overflow Chamber Kit 24E298Repair Kits 312795E Performance Charts Model B15Bxx Fluid Outlet Pressure psi MPa, barMin BarMPa PressureModel B25Bxx Fluid Cycles per MinutePump Dimensions ModelWall Bracket Mounting Dimensions Technical DataGraco Standard Warranty Graco Information