Merkury Innovations 312795E Repair, Preparation, Disconnect the Pump, Hold Turn

Page 18

Repair

Repair

2. Loosen the four mounting nuts. Use two people to lift the entire pump up and out from the mounting plate. Place it on a work bench.

General Information

Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing.

Always use Genuine Graco Parts and Accessories, available from your Graco distributor. If you supply your own accessories, be sure they are adequately sized and pressure rated for your system.

Disconnect the Displacement Pump

1.Follow all steps under Preparation, page 18.

2.Loosen the screws on the top cap.

3.Hold the coupling nut (7) with a wrench. Use another wrench to turn the motor shaft. To avoid damage to the bellows top cap and the D-shaped seal, do not turn the coupling nut.

Preparation

1.Flush the pump, if possible, page 16.

2.Stop the pump close to the middle of the stroke.

3.Follow Pressure Relief Procedure, page 14.

4.Disconnect the air and fluid hoses and the ground wire.

5.Remove the shield.

NOTE: If the overflow chamber (optional accessory) contains fluid, unscrew the bottle (103) and discard. If it has not been used, the bottle can remain attached to the cap.

To avoid the buildup of electrostatic charge, do not rub the plastic bottle with a dry cloth while it is attached to the pump. Remove the bottle to clean, if needed.

Disconnect the Pump

NOTE: Follow these instructions to remove the entire pump from the wall or cart bracket. For wall-mounted packages, you may prefer to remove the entire pump, even if only the air motor requires repair.

1. Follow all steps under Preparation, page 18.

hold

turn

ti14531a

FIG. 7. Loosen the coupling nut.

4.Lower the coupling nut (7) and remove the coupling collars (5).

ti15365a

FIG. 8. Remove coupling collars.

18

312795E

Image 18
Contents Merkur Bellows Pump Assembly II 2 G c IIB T3 200CContents Related ManualsFire and Explosion Hazard Equipment Misuse Hazard Important Two-Component Material Information Models Smarts/Exhaust PackingsMotor Pump Air Displacement Working Pressure At 60 cpm FluidPump Data Fluid Inlet Outlet Air InletComponent Identification Component Identification KeyComponent Identification 312795E Installation General InformationPrepare the Operator Typical Cart-Mount Installation Key Prepare the SiteAir and Fluid Hoses GroundingMount the Pump Wall-Mounted PumpsAccessories Air LineFluid Line Flush the Pump Before First Use Pressure Relief ProcedureOperation Trigger LockPrime and Adjust the Pump Shutdown and Care of the PumpFollow Pressure Relief Procedure, MaintenancePreventive Maintenance Schedule Tighten Threaded ConnectionsTroubleshooting Problem Cause SolutionPreparation Disconnect the Displacement PumpRepair Disconnect the PumpDisconnect the Air Motor Reconnect the Displacement Pump Reconnect the PumpReconnect the Air Motor Repair 312795E Parts Parts That Vary by Model Part No./DescriptionCart Mounting Kit 24E879 Repair KitsWall Mounting Kits Overflow Chamber Kit 24E298Repair Kits 312795E Performance Charts Model B15Bxx Fluid Outlet Pressure psi MPa, barMPa MinBar PressureModel B25Bxx Fluid Cycles per MinutePump Dimensions ModelWall Bracket Mounting Dimensions Technical DataGraco Standard Warranty Graco Information