Merkury Innovations 312795E Reconnect the Pump, Reconnect the Air Motor

Page 20

Repair

Reconnect the Air Motor

1.Screw the tie rods (3) into the bottom cover of the air motor. Torque to 50-55 ft-lb (68-75 N•m).

2.As needed for the larger air motors, use two people to reattach. Align the tie rods (3) with the holes in the pump adapter. Carefully lower the air motor into place.

3.Attach the tie rod nuts (4) and torque to 50-60 ft-lb (68-81 N•m).

4.Tighten the mounting screws.

5.Hold the motor shaft up with one hand. With your other hand, put the coupling nut (7) on the displace- ment rod.

6.Put the coupling collars (5) into the coupling nut (7) so large flanges point upward.

7.Gently let the motor shaft drop onto the displace- ment rod. Torque the coupling nut (7) to 75-80 ft-lb (138-146 N•m).

8.Connect the air and fluid hoses, the ground wire, and the shield.

Reconnect the Displacement Pump

1.Align the straight edge of the pump adapter with the back of the air motor. Slide the pump adapter onto the tie rods (3).

2.Attach the tie rod nuts (4) and torque to 50-60 ft-lb (68-81 N•m).

3.Tighten the mounting screws.

4.Hold the motor shaft up with one hand. With your other hand, put the coupling nut (7) on the displace- ment rod.

5.Put the coupling collars (5) into the coupling nut (7) so large flanges point upward.

6.Gently let the motor shaft drop onto the displace- ment rod. Torque the coupling nut (7) to 75-80 ft-lb (138-146 N•m).

7.Connect the air and fluid hoses, the ground wire, and the shield.

Reconnect the Pump

NOTE: If the entire pump has been removed and is now reassembled, follow these directions:

1.Use two people to lift the pump into place. Slide it in and down onto the mounting plate.

2.Tighten the mounting screws.

3.Connect the air and fluid hoses, the ground wire, and the shield.

20

312795E

Image 20
Contents Merkur Bellows Pump Assembly II 2 G c IIB T3 200CContents Related ManualsFire and Explosion Hazard Equipment Misuse Hazard Important Two-Component Material Information Models Smarts/Exhaust PackingsAir Displacement Working Pressure At 60 cpm Fluid Pump DataMotor Pump Fluid Inlet Outlet Air InletComponent Identification Component Identification KeyComponent Identification 312795E Prepare the Operator InstallationGeneral Information Typical Cart-Mount Installation Key Prepare the SiteGrounding Mount the PumpAir and Fluid Hoses Wall-Mounted PumpsFluid Line AccessoriesAir Line Pressure Relief Procedure OperationFlush the Pump Before First Use Trigger LockPrime and Adjust the Pump Shutdown and Care of the PumpMaintenance Preventive Maintenance ScheduleFollow Pressure Relief Procedure, Tighten Threaded ConnectionsTroubleshooting Problem Cause SolutionDisconnect the Displacement Pump RepairPreparation Disconnect the PumpDisconnect the Air Motor Reconnect the Air Motor Reconnect the Displacement PumpReconnect the Pump Repair 312795E Parts Parts That Vary by Model Part No./DescriptionRepair Kits Wall Mounting KitsCart Mounting Kit 24E879 Overflow Chamber Kit 24E298Repair Kits 312795E Performance Charts Model B15Bxx Fluid Outlet Pressure psi MPa, barMin BarMPa PressureModel B25Bxx Fluid Cycles per MinutePump Dimensions ModelWall Bracket Mounting Dimensions Technical DataGraco Standard Warranty Graco Information