Johnson Controls PC090 THRU 240, PD 180 THRU 240 dimensions 410A

Page 1

R-410A

MODELS: PC090 Thru 240

PD180 Thru 240

7.5 - 20 Ton

60 Hertz

TABLE OF CONTENTS

Nomenclature

2

Electrical Data

. 9

General

2

Refrigerant Mains

10

Renewal Parts

3

Piping And Electrical Connections

17

Agency Approvals

3

Start-Up

17

Inspection

3

Crankcase Heaters

17

Physical Data

4

Operation

18

Installation

5

Sequence of Operation

18

Limitations

5

Cooling Sequence Of Operation

18

Location

5

Heating Sequence of Operation

20

Clearances

7

Unit Control Board Option Setup

23

Rigging

7

Troubleshooting

23

Phasing

8

Typical Wiring Diagrams

30

LIST OF TABLES

1

PC090 - 240 and PD180 - 240 Physical Data

4

7

PC090, PC120 Unit Height Dimensions

15

2

Unit Application Data

5

8

PC/PD180 & PC/PD240 Unit Height Dimensions

16

3

Corner Weights & Center of Gravity

6

9

Piping and Electrical Connection Sizes

17

4

Minimum Clearances

7

10

PC090 thru 240 Unit Control Board Flash Codes

21

5

Electrical Data - Outdoor Unit - HP Without Powered

9

11

PD180 thru 240 Unit Control Board Flash Codes

22

 

Convenience Outlet

 

 

 

6

Electrical Data - Outdoor Unit - HP With Powered

9

 

 

 

 

Convenience Outlet

 

 

 

LIST OF FIGURES

1 Corner Weights & Center Of Gravity . . . . . . . . . . . . . . . . 6 2 Typical Rigging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 3 Typical Field Wiring Diagram - NC090 Air Handling Unit

With PC090 Heat Pump . . . . . . . . . . . . . . . . . . . . . . . . . 12

4 Typical Field Wiring Diagram - NC120 thru 240 Evaporator Unit with PC120 thru 240 Heat Pump . . . . . . . . . . . . . . 13

5 NC120 - 240 Liquid Line Solenoid Wiring . . . . . . . . . . . 13 6 Typical Field Wiring Diagram - ND180 thru 240

Evaporator Unit with PD180 thru 240 Heat Pump . . . . . 14

7 PC090, PC120 Unit Dimensions . . . . . . . . . . . . . . . . . . 15 8 PC/PD180 & PC/PD240 Unit Dimensions and Piping

& Electrical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . 16

9 Fan Orientation, Control Box End . . . . . . . . . . . . . . . . . 21 10 Unit Control Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 11 PC090 Charging Chart. . . . . . . . . . . . . . . . . . . . . . . . . . 27 12 PC120 Charging Chart. . . . . . . . . . . . . . . . . . . . . . . . . . 27 13 PC180 Charging Chart. . . . . . . . . . . . . . . . . . . . . . . . . . 28 14 PD180 Charging Chart. . . . . . . . . . . . . . . . . . . . . . . . . . 28 15 PC240 Charging Chart. . . . . . . . . . . . . . . . . . . . . . . . . . 29 16 PD240 Charging Chart. . . . . . . . . . . . . . . . . . . . . . . . . . 29 17 Typical PC090 Heat Pump Wiring Diagram . . . . . . . . . . 30 18 Typical PC120 Heat Pump Wiring Diagram . . . . . . . . . . 31 19 Typical PC180 - 240 Heat Pump Wiring Diagram . . . . . 32 20 Typical PD180 - 240 Heat Pump Wiring Diagram . . . . . 33

430645-YIM-D-0610

Image 1
Contents 410A General NomenclatureRenewal Parts Safety ConsiderationsAgency Approvals InspectionPC090 240 and PD180 240 Physical Data Physical DataLimitations InstallationLocation Shipping Operating Corner Weights & Center of GravityRigging ClearancesMinimum Clearances Clearance Description Distance in Inches Control Wiring Power WiringPhasing CompressorsFLA Electrical DataRefrigerant Mains Take Adequate PrecautionsLine Sizing Start Installation Thermostat Single Stage Cooling TWO Stage Heating NC120 240 Liquid Line Solenoid Wiring YIM-D-0610 Model Model Piping And Electrical Connections Start-UpCrankcase Heaters Sequence of Operation OperationCooling Sequence Of Operation Dual Stage Heat Pump 4 pipe PD180-240 Dual Stage Heat Pump PC120-240Heating Sequence of Operation Fan Orientation, Control Box End Defrost OperationUnit Control Board PD180 thru 240 Unit Control Board Flash CodesUnit Control Board Option Setup TroubleshootingOption Byte Setup Normal MaintenanceCooling Troubleshooting Guide If none of the above correct the error, replace the UCB Johnson Controls Unitary Products Cooling Charging Curves Cooling Charging Curves PC240 Typical PC090 Heat Pump Wiring Diagram Typical Wiring DiagramsTypical PC120 Heat Pump Wiring Diagram Typical PC180 240 Heat Pump Wiring Diagram Johnson Controls Unitary Products York Drive Norman, OK

PC090 THRU 240, PD 180 THRU 240 specifications

Johnson Controls has long been a leader in the HVAC and building efficiency industry, and the Johnson Controls PC090 THRU 240 and PD 180 THRU 240 series of commercial rooftop units exemplify their commitment to innovation and energy efficiency. These units are designed to provide optimal performance for a wide range of commercial applications, ensuring comfortable indoor climates while maintaining energy savings.

One of the standout features of the Johnson Controls PC and PD series is their advanced cooling and heating capabilities. Both series can operate efficiently across a varied range of capacities, typically from 90,000 to 240,000 BTU/h for the PC series and 180,000 to 240,000 BTU/h for the PD series. This versatility allows users to select the most appropriate unit size for their specific needs, optimizing performance without wasting energy.

The technology behind these rooftop units includes advanced inverter-driven compressors that enable variable-speed operation. This feature allows for precise temperature control, resulting in enhanced comfort and reduced energy usage. The units also integrate smart controls that enable easy monitoring and management, ensuring that the HVAC system can adapt to changes in occupancy or external weather conditions.

Another notable characteristic of the Johnson Controls rooftop units is their robust construction and reliability. Designed for outdoor use, these units can withstand harsh weather conditions while maintaining operational efficiency. They are equipped with corrosion-resistant materials and protective enclosures to prolong the life of the equipment.

The units are also engineered with eco-friendliness in mind, utilizing refrigerants with low global warming potential to minimize their environmental impact. Furthermore, their energy-efficient designs often qualify for various energy incentives, providing businesses an additional return on investment.

Ease of installation and maintenance is another hallmark of the PC and PD series. With a modular design, these units can be easily transported and installed. Maintenance tasks are simplified, allowing facility management teams to perform regular service checks efficiently and effectively.

Overall, the Johnson Controls PC090 THRU 240 and PD 180 THRU 240 series stand out in the commercial HVAC market due to their flexibility, advanced technology, and dedication to energy efficiency and environmental responsibility. These units not only meet modern energy codes but also contribute to a sustainable future with their innovative features and reliable performance.