Johnson Controls CSV060B-240B installation instructions Read Before Proceeding

Page 2

FORM 145.15-IOM7 (412)

IMPORTANT!

READ BEFORE PROCEEDING!

GENERAL SAFETY GUIDLINES

This equipment is a relatively complicated apparatus. During installation, operation, maintenance or service, individuals may be exposed to certain components or conditions including, but not limited to: refrigerants, oils, materials under pressure, rotating components, and both high and low voltage. Each of these items has the potential, if misused or handled improperly, to cause bodily injury or death. It is the obligation and respon- sibilty of operating/service personnel to identify and recognize these inherent hazards, protect themselves, and proceed safely in completing their tasks. Failure to comply with any of these requirements could result in serious damage to the equipment and the property in

which it is situated, as well as sever personal injury or death to themselves and people at the site.

This document is intended for use by owner-authorized operating/service personnel. It is expected that this individual possesses independent training that will en- able them to perform their assigned tasks properly and safely. It is essential that, prior to performing any task on this equipment, this individual shall have read and understood this document and any referenced materials. This individual shall also be familiar with and comply with all applicable governmental standards and regulations pertaining to the task in question.

SAFETY SYMBOLS

The following symbols are used in this document to alert the reader to areas of potential hazard.

DANGER indicates an imminently haz- ardous situation which, if not avoided, will result in death or serious injury.

WARNING indicates a potentially haz- ardous situation which, if not avoided, could result in death or serious injury.

CAUTION identifies a hazard which could lead to damage to the machine, damage to other equipment and/or environmental pollution. Usually and instruction will be given, together with a brief explanation.

NOTE is used to highlight additional in- formation which may be helpful to you.

All wiring must be in accordance with published specifications and must be performed ONLY by qualified service personnel. Johnson Controls will not be responsible for damages/problems resulting from improper connections to the controls or application of improper control signals. Failure to follow this will void the manufacturers warranty and cause serious damage to prop- erty or injury to persons.

2

JOHNSON CONTROLS

Image 2
Contents Model CSV Vertical R-410A Read Before Proceeding Changeability of this Document CSV Operating Weight Unit Shipping Weight Lbs General InformationUnit Mounting Water PipingCSV060 Dimensional Data CSV096-120 Dimensional Data CSV180 Dimensional Data CSV240 Dimensional Data Ductwork Evaporator Blower Discharge ConversionElectrical Wiring Typical Wiring Schematic Johnson Controls Johnson Controls Johnson Controls Electrical Data Oversized Evaporator Motor Electrical Data Electrical Data Standard Evaporator MotorModel # CSV120B FAN Performance CSV060BCSV096B CSV180B CSV240BMotor and Pulley Data EVAPORATOR-STANDARD Blower Motor and Drive DataBlower Speed Adjustment Unit Flow Rate GPM Water Pressure Drop DataDrop Pressure Drop FT H20 Unit Flow Rate GPMSTART-UP and Operation UnitOperation Safety SwitchesMicroprocessor Controller Continuous BlowerCondensate Overflow Switch Safety ControlsFlash Codes Blower Evaporator CoilRefrigerant Circuits Drive Belt410A Quick Reference Guide Form 145.15-IOM7

CSV060B-240B specifications

The Johnson Controls CSV060B-240B is a cutting-edge packaged rooftop air conditioning unit designed for commercial applications, renowned for its energy efficiency, reliability, and advanced technological features. This model exemplifies the balance between performance and sustainability, making it a prime choice for businesses seeking effective climate control solutions.

One notable feature of the CSV060B-240B is its variable speed compressor technology. This innovative design allows the unit to adjust its cooling output in response to real-time demand, which significantly enhances energy efficiency. By operating at lower speeds during moderate cooling loads, the system consumes less energy while maintaining consistent indoor comfort. This not only reduces operational costs but also minimizes the environmental impact associated with energy consumption.

In addition to its variable speed compressor, the CSV060B-240B is equipped with advanced intelligent controls. These controls enable users to integrate the unit into building management systems, allowing for seamless monitoring and adjustments. Features such as remote connectivity and smartphone integration provide added convenience, allowing facility managers to optimize system performance from anywhere.

Another key characteristic of the CSV060B-240B is its robust construction designed for durability and easy maintenance. The unit comes with a weatherproof cabinet, which protects internal components from harsh environmental conditions. This design extends the lifespan of the unit and reduces downtime due to maintenance or repairs. Additionally, the access panels are strategically placed to facilitate easy servicing, making it user-friendly for maintenance personnel.

The CSV060B-240B also emphasizes quiet operation, making it ideal for environments where noise levels need to be kept in check, such as hospitals, schools, and offices. Enhanced sound insulation and the use of a quiet fan design contribute to a more pleasant indoor atmosphere.

Overall, the Johnson Controls CSV060B-240B stands out in the market due to its combination of energy efficiency, smart technology, durability, and quiet operation. It is an excellent investment for businesses aiming to enhance their HVAC systems while adhering to sustainability practices and ensuring the comfort of their occupants. The CSV060B-240B not only meets the demands of modern commercial spaces but also sets a new standard for HVAC performance and innovation.