Johnson Controls CSV060B-240B installation instructions CSV180B, CSV240B

Page 18

FORM 145.15-IOM7 (412)

CSV180B

SUPPLY AIR BLOWER PERFORMANCE

SUPPLY

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE - Inches W.C. ¹

 

 

 

 

 

 

 

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

 

2.0

CFM

 

 

 

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

 

RPM

BHP

 

 

 

 

 

Field

Supplied

Low

Static

 

 

Standard Factory Drive + 3 HP

 

 

 

 

Optional Hi-Static Drive + 5 HP

 

 

 

 

 

Drive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4800

 

634

1.20

697

1.42

757

1.62

813

1.84

867

2.06

918

2.30

968

2.52

1015

2.76

1065

3.02

 

1109

3.32

5400

 

701

1.66

758

1.90

812

2.14

864

2.38

914

2.62

962

2.88

1009

3.12

1053

3.38

1097

3.66

 

1139

3.92

6000

 

765

2.22

817

2.48

867

2.74

916

3.00

962

3.28

1007

3.54

1051

3.82

1093

4.10

1134

4.38

 

1174

4.68

6600

 

832

2.90

880

3.20

927

3.48

972

3.76

1015

4.06

1057

4.34

1099

4.64

1139

4.96

~

~

 

~

~

7200

 

900

3.72

945

4.02

988

4.34

1030

4.64

1070

4.96

~

~

~

~

~

~

~

~

 

~

~

1.Blower performance includes evaporator coil and 2" filters

2.At higher evaporator airflows and wet bulb conditions, condensate carry-over may occur. Decrease airflow downward as necessary.

CSV240B

SUPPLY AIR BLOWER PERFORMANCE

SUPPLY

 

 

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE - Inches W.C. ¹

 

 

 

 

 

 

 

0.2

0.4

0.6

 

0.8

1.0

1.2

1.4

1.6

 

1.8

2.0

CFM

 

 

 

 

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

 

 

 

 

 

Field Supplied Low Static Drive

 

 

 

 

 

Standard Factory Drive + 5 HP

 

 

 

 

Optional Hi-Static Drive +7.5HP

6400

 

705

1.96

 

2.22

 

 

2.48

 

862

2.72

910

3.02

 

3.28

1001

 

3.56

 

3.84

 

1085

4.12

1125

4.42

 

760

812

 

 

956

 

1043

 

7200

 

788

2.76

837

3.06

884

 

3.34

 

930

3.64

952

3.78

995

4.08

1037

 

4.38

1078

4.70

 

1118

5.00

1156

5.32

8000

 

861

3.70

906

4.02

950

 

4.34

 

992

4.66

1033

4.98

1073

5.32

1111

 

5.66

1149

5.98

 

1186

6.32

1222

6.68

8800

 

949

4.94

970

5.12

1010

 

5.46

 

1049

5.82

1087

6.18

1125

6.52

1161

 

6.90

1197

7.26

 

~

~

~

~

9600

 

1028

6.34

1066

6.72

1103

 

7.10

 

1139

7.48

~

~

~

~

~

 

~

~

~

 

~

~

~

~

1.Blower performance includes evaporator coil and 2" filters

2.At higher evaporator airflows and wet bulb conditions, condensate carry-over may occur. Decrease airflow downward as necessary.

18

JOHNSON CONTROLS

Image 18
Contents Model CSV Vertical R-410A Read Before Proceeding Changeability of this Document CSV Operating Weight Unit Shipping Weight Lbs General InformationUnit Mounting Water PipingCSV060 Dimensional Data CSV096-120 Dimensional Data CSV180 Dimensional Data CSV240 Dimensional Data Ductwork Evaporator Blower Discharge ConversionElectrical Wiring Typical Wiring Schematic Johnson Controls Johnson Controls Johnson Controls Electrical Data Electrical Data Standard Evaporator Motor Model #Electrical Data Oversized Evaporator Motor FAN Performance CSV060B CSV096BCSV120B CSV180B CSV240BMotor and Pulley Data EVAPORATOR-STANDARD Blower Motor and Drive DataBlower Speed Adjustment Unit Flow Rate GPM Water Pressure Drop DataDrop Pressure Drop FT H20 Unit Flow Rate GPMSTART-UP and Operation UnitOperation Safety SwitchesMicroprocessor Controller Continuous BlowerCondensate Overflow Switch Safety ControlsFlash Codes Blower Evaporator CoilRefrigerant Circuits Drive Belt410A Quick Reference Guide Form 145.15-IOM7