Johnson Controls 341426-BIM-A-0108 installation manual Physical Data, Electrical Data

Page 10

341426-BIM-A-0108

TABLE 7: PHYSICAL DATA

 

MODEL

 

 

DYA

 

 

 

 

 

 

 

 

036

042

 

048

060

 

 

 

EVAPORATOR

CENTRIFUGAL BLOWER (Dia. x W. in.)

11 x 10

11 x 10

 

12 x 11

12 x 11

BLOWER

FAN MOTOR HP (3 Speed)

3/4

3/4

 

1

1

 

 

 

 

 

 

 

EVAPORATOR

ROWS DEEP

2

3

 

3

3

FINS PER INCH

15

13

 

13

13

COIL

 

FACE AREA (Sq. Ft.)

3.5

3.5

 

4.5

4.5

 

 

 

 

 

 

 

 

 

CONDENSER

PROPELLER DIA. (in.)

22

22

 

22

22

FAN MOTOR HP

1/4

1/4

 

1/4

1/4

FAN

 

NOM. CFM TOTAL

2,400

2,400

 

3,000

3,000

 

 

 

 

 

 

 

 

 

CONDENSER

ROWS DEEP

1

1

 

1

1

FINS PER INCH

20

20

 

20

20

COIL

 

FACE AREA (Sq. Ft.)

11.7

11.7

 

14.8

14.8

 

 

 

 

 

 

 

 

 

CHARGE

REFRIGERANT 22 (lbs./oz.)

4 / 3

4 / 9

 

6 / 0

5 / 4

 

 

 

 

 

 

 

FILTER1

FACE AREA (Sq. Ft.) Size (Nominal)

2.6/20x20

2.6/20x20

 

3.3/20x12

3.3/20x12

 

NATURAL GAS BURNER ORIFICE NO.

43

43

 

40

40

 

(Drill Size)

 

FURNACE

 

 

 

 

 

PROPANE BURNER ORIFICE NO.

55

55

 

53

53

SECTION

 

(Drill Size)

 

 

 

 

 

 

 

 

GAS CONNECTION SIZE

1/2 NPTI

1/2 NPTI

 

1/2 NPTI

1/2 NPTI

 

 

 

 

 

 

 

COMPRESSOR

HERMETICALLY SEALED

R

R

 

S

S

TYPE

(R = RECIPROCATING, S = SCROLL)

 

 

 

 

 

 

1.Three phase 036 thru 042 size units are supplied with one (1) filter and on three phase 048 and 060 size units two (2) filters are supplied. See FILTERS on page 5.

TABLE 8: ELECTRICAL DATA

 

 

VOLTAGE

COMPRESSOR

COND.

SUPPLY

 

MAX.

MAX.

 

 

MODEL

POWER

LIMITATIONS1

AIR

MINIMUM

HACR

UNIT

TRANSFORMER

 

 

FAN

FUSE

DYA

SUPPLY

 

 

 

 

MOTOR,

BLOWER

CIRCUIT

SIZE,

BREAKER

POWER

SIZE (VA)

MIN.

MAX.

RLA

LRA

 

 

FLA

MOTOR

AMPACITY

AMPS2

SIZE,

FACTOR

 

 

 

 

 

 

 

 

FLA

 

 

AMPS

 

 

036

208/230-3-60

187

253

10.9

78.0

1.1

3.5

18.2

25

25

.96

75

036

460-3-60

414

504

5.8

40.0

0.6

1.8

9.6

15

15

.96

75

042

208/230-3-60

187

253

11.5

88.0

1.1

3.5

19.0

25

25

.96

75

042

460-3-60

414

504

5.8

42.0

0.6

1.8

9.7

15

15

.96

75

048

208/230-3-60

187

253

14.1

105

1.3

7.0

25.9

35

35

.96

75

048

460-3-60

414

504

7.1

55.0

0.7

3.5

13.1

20

20

.96

75

 

 

 

 

 

 

 

 

 

 

 

 

 

060

208/230-3-60

187

253

15.5

125

1.3

7.0

29.5

40

40

.96

75

 

 

 

 

 

 

 

 

 

 

 

 

 

060

460-3-60

414

504

8.9

66.5

0.7

3.5

15.4

20

20

.96

75

1.Utilization range “A” in accordance with ARI Standard 110.

2.Dual element, time delay type.

10

Johnson Controls Unitary Products

Image 10
Contents Installation Manual Table of Contents Inspection GeneralApprovals Renewal PartsUnit Application Data InstallationLimitations LocationDuct Work Unit Weights and Center of GravityService Access Roof CurbThermostat Power and Control WiringCompressors Natural GAS Application Data PROPANE1 LP GAS Application DataGAS Piping Natural GAS Pipe Sizing CHART1Propane LP GAS Pipe Sizing CHART1 GAS ConnectionFlue Vent Hood Flue Vent Outlet AIR HoodPhysical Data Electrical DataUnit Dimensions Front Unit Minimum CLEARANCES1Unit Dimensions Front & Bottom Sequence of Operation HeatingPost Purge START-UP POST-START Check List GAS Manifold GAS Pressure AdjustmentPilot Instructions Adjustment of Temperature Rise Checking GAS InputGase Rate Cubic Feet PER HOUR1 Checking Supply AIR CFMDYA Coil Delta P vs Airflow Superheat Charging Table for DYA048 Superheat Charging Table for DYA042Superheat Charging Table for DYA060 BIM-A-0108 BIM-A-0108 Typical Wiring Diagram Notes See Figures 14Typical Wiring Diagram Legend