Johnson Controls 341426-BIM-A-0108 Natural GAS Application Data, PROPANE1 LP GAS Application Data

Page 7

341426-BIM-A-0108

TABLE 3: NATURAL GAS APPLICATION DATA

 

INPUT CAPACITY

OUTPUT

GAS RATE

2

NUMBER OF

TEMP. RISE °F AT FULL

 

 

INPUT3

AVAILABLE ON MODELS

CAPACITY

 

(MBH)1

 

 

 

(MBH)

FT.3/HR.

 

BURNERS

 

 

 

 

 

MIN.

 

MAX.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 & 3-1/2 TON

45

36

42

 

2

25

 

55

 

 

 

 

 

 

 

 

 

3 & 3-1/2 TON

70

56

65

 

3

25

 

55

 

 

 

 

 

 

 

 

 

4 & 5 TON

80

64

74

 

3

25

 

55

 

 

 

 

 

 

 

 

 

3 & 3-1/2 TON

90

72

84

 

4

30

 

60

 

 

 

 

 

 

 

 

 

4 & 5 TON

108

87

100

 

4

30

 

60

 

 

 

 

 

 

 

 

 

4 & 5 TON

135

108

126

 

5

35

 

65

 

 

 

 

 

 

 

 

 

1.Heating capacity valid for elevations up to 2000 feet above sea level. For elevations above 2,000 feet, rated capacity should be reduced by 4% for each 1,000 feet above sea level.

2.Based on 1075 BTU/Ft.3.

3.The air flow must be adjusted to obtain a temperature rise within the range shown. Continuous return air temperature should not be below 55°F.

TABLE 4: PROPANE1 (LP) GAS APPLICATION DATA

 

INPUT CAPACITY

OUTPUT

GAS RATE

3

NUMBER OF

TEMP. RISE °F AT FULL

AVAILABLE ON MODELS

 

INPUT4

(MBH)2

 

 

 

CAPACITY (MBH)

FT.3/HR.

 

BURNERS

 

 

 

 

 

MIN.

 

MAX.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 & 3-1/2 TON

45

36

18

 

2

25

 

55

 

 

 

 

 

 

 

 

 

3 & 3-1/2 TON

70

56

28

 

3

25

 

55

 

 

 

 

 

 

 

 

 

4 & 5 TON

80

64

32

 

3

25

 

55

 

 

 

 

 

 

 

 

 

3 & 3-1/2 TON

90

72

36

 

4

30

 

60

 

 

 

 

 

 

 

 

 

4 & 5 TON

108

87

43

 

4

30

 

60

 

 

 

 

 

 

 

 

 

4 & 5 TON

135

108

54

 

5

35

 

65

 

 

 

 

 

 

 

 

 

1.Propane applications are accomplished by field installation of a Propane Conversion Accessory, Model 1NP0807 for 3 and 3-1/2 ton units with 33-1/2” tall cabinets and Model 1NP0808 for 4 and 5 ton units with 41-1/2” tall cabinets.

2.Heating capacity valid for elevations up to 2,000 feet above sea level. For elevations above 2,000 feet, rated capacity should be reduced by 4% for each 1,000 feet above sea level.

3.Based on 2500 BTU/Ft.3.

4.The air flow must be adjusted to obtain a temperature rise within the range shown. Continuous return air temperatures should not be below 55°F.

Johnson Controls Unitary Products

7

Image 7
Contents Installation Manual Table of Contents Renewal Parts GeneralApprovals InspectionLocation InstallationLimitations Unit Application DataRoof Curb Unit Weights and Center of GravityService Access Duct WorkThermostat Power and Control WiringCompressors PROPANE1 LP GAS Application Data Natural GAS Application DataGAS Connection Natural GAS Pipe Sizing CHART1Propane LP GAS Pipe Sizing CHART1 GAS PipingFlue Vent Outlet AIR Hood Flue Vent HoodElectrical Data Physical DataUnit Minimum CLEARANCES1 Unit Dimensions FrontUnit Dimensions Front & Bottom Heating Sequence of OperationPost Purge START-UP POST-START Check List GAS Manifold GAS Pressure AdjustmentPilot Instructions Checking GAS Input Adjustment of Temperature RiseChecking Supply AIR CFM Gase Rate Cubic Feet PER HOUR1DYA Coil Delta P vs Airflow Superheat Charging Table for DYA048 Superheat Charging Table for DYA042Superheat Charging Table for DYA060 BIM-A-0108 BIM-A-0108 See Figures 14 Typical Wiring Diagram NotesTypical Wiring Diagram Legend