Optima Company 1001 installation instructions Installation Details, Position

Page 8

1001

Installation Details

Gas Safety (Installation & Use) Regulations: 1994

In the interest of safety, it is the law that all gas appliances are installed by a competent person in accordance with the above Regulations, Building Regulations/Building Standards Scotland, Codes of Practice, current I.E.E. Regulations and the byelaws of the Local Water Undertaking. Failure to comply with the Regulations may lead to prosecution; it is in your interest and that of safety to ensure that the law is complied with.

Important - If the boiler is to be fitted in a timber framed building it should be fitted in accordance with the British Gas publication; Guide for Gas Installation in Timber Frame Housing: Reference DM2. If in doubt advice must be sought from the Local Gas Region of British Gas Plc.

Location of Boiler

The installation of the 1001 must be on a suitable non-combustible load bearing wall which will provide an adequate fixing for the boiler mounting bracket assembly. The location should be in an area where the water pipes will not be subjected to frost conditions. In siting the combination boiler the following limitations must be observed:

The combination boiler may be installed in any room or internal space, although particular attention is drawn to the requirements of the current, i.e. wiring regulations and in Scotland the electrical provisions of the building regulations applicable in Scotland, with respect to the installation of the combination boiler in a room or internal space containing a bath or shower.

Where a room sealed appliance is installed in a room containing a bath or shower any electrical switch or appliance control utilising mains electricity, should be so situated that it cannot be touched by a person using the bath or shower.

Terminal Position

POSITION

MINIMUM SPACING (fig. 3)

mm

A

Directly below an openable window, air vent, or any other ventilation opening

300

B

Below gutters, soil pipes or drainpipes

75

C

Below Eaves

100

D

Below a Balcony

100

E

From vertical drainpipes or soilpipes

75

F

From internal or external corners

100

G

Above adjacent ground or balcony level

100

H

From a surface facing the terminal

600

I

Facing another terminal

1,200

J

From opening (door/window) in carport into dwelling

1,200

K

Vertically from a terminal on the same wall

300

L

Horizontally from a terminal on the same wall

300

N

Below carport

600

A Quinnel Barrat and Quinnel guard (part. No. C2) should be screwed to the wall centrally over the terminal, when the distance is less than 2 m from the outside floor.

Air Supply

The room, cupboard or compartment in which the boiler is installed does not require a purpose provided vent.

8

Image 8
Contents Installer Service Engineer Serial NoPhone numbers Help Telephone 08707 2821001 IndexGeneral Description Related DocumentsTechnical data Natural GAS G20 Propane LPG G31Appliance Dimensions KeyBoiler Flow Diagram 1001 Installation Details PositionTerminal Position Minimum Clearance mm Flue system Gas SupplyWater System Central Heating Make up WaterKey Built-in Central Heating Water Circulating Pump Pump performance curve Grundfos UPSInstallation UnpackingDrilling template = 22 mm 5 = 15 mmPreparing the Flue Assembly Rear Flue Outlet figUsed later Side Flue Outlet figConnecting the Boiler Fixing points Lift here Fixing screws Procedure With Sufficient Clearance To Insert Assembly From InsideWith insufficient Clearance To Insert Assembly From Inside Commissioning and Testing Gas InstallationFilling the Central Heating System Filling the Domestic Hot Water SystemTo Light the Boiler fig Burner Pressure C.H. and D.H.W ProcedureBurner Pressure C.H. and D.H.W Coil Burner Perssure C.H Burner pressure VS C.H. Load with L.P.G. G31 PropaneHanding Over to the User D.H.W. Burner PressureSystem Operation Display. Symbol Time ClockOver ride Reset ButtonReset is only possible with switch a in set Clock position 136 101 Spare Parts List 100H.W Temperature VS. flow =Cold Water 15 C =Cold Water 5 C H.W. Pressure Drop VS. flowConnector Jumpers JP1 JP4 Temp OhmSensor RY not energisedSpecial Air Intake/Flue Outlet Phone numbers Installer Service Engineer

1001 specifications

Optima Company 1001 stands at the forefront of innovation, showcasing a remarkable blend of advanced technology and user-centric design. Founded with the vision of revolutionizing the industry, Optima has quickly positioned itself as a leader in producing high-performance solutions that cater to a diverse clientele.

One of the main features of Optima Company 1001 is its commitment to sustainability. The company has integrated eco-friendly practices into its manufacturing processes, allowing for reduced waste and lower energy consumption. This not only benefits the environment but also enhances the overall efficiency of its products. By utilizing recyclable materials and implementing sustainable sourcing practices, Optima ensures that it remains at the cutting edge of corporate responsibility.

Another hallmark of Optima Company 1001 is its dedication to technological advancement. The firm employs state-of-the-art technologies that resonate with the demands of modern consumers. This includes the use of artificial intelligence and machine learning to optimize operational efficiency and personalize user experiences. Through data analytics, Optima is able to anticipate trends and adapt its offerings, ensuring that customers always receive the most relevant solutions.

Durability and reliability are pivotal characteristics of products manufactured by Optima Company 1001. Each product undergoes rigorous testing to meet high standards of quality and performance. This commitment to excellence means that customers can trust in the longevity and functionality of the products they purchase, giving them peace of mind in their investment.

User-friendliness is also a defining trait of Optima’s offerings. The company places great emphasis on design, ensuring that products are intuitive and accessible to users. This focus on usability is reflected in straightforward interfaces and ergonomic designs that enhance the overall user experience.

Furthermore, Optima Company 1001 prioritizes customer service, providing comprehensive support throughout the product lifecycle. This includes installation assistance, maintenance services, and a robust warranty program, underscoring the company’s dedication to customer satisfaction.

In summary, Optima Company 1001 is characterized by its innovative technologies, commitment to sustainability, product reliability, user-centric design, and exemplary customer service. These features collectively enhance its reputation as an industry leader and pioneer in delivering solutions that are not only high-quality but also aligned with the needs and values of today’s consumers.