GE AET05, AEW08 Troubleshooting Tips, Normal Operating Sounds, Problem Possible Causes What To Do

Page 12

Consumer Support Troubleshooting Tips Installation Instructions Operating Instructions Safety Instructions

Troubleshooting Tips.

Problem

 

Possible Causes

What To Do

 

 

 

 

Air conditioner

 

The air conditioner

Make sure the air conditioner plug is pushed

does not start

 

is unplugged.

completely into the outlet.

 

 

 

 

 

 

The fuse is blown/circuit

Check the house fuse/circuit breaker box and replace

 

 

breaker is tripped.

the fuse or reset the breaker.

 

 

 

 

 

 

Power failure.

The unit will automatically re-start in the settings last

 

 

 

used after the power is restored.

 

 

 

There is a protective time delay (approximately

 

 

 

3 minutes) to prevent tripping of the compressor

 

 

 

overload. For this reason, the unit may not start

 

 

 

normal cooling for 3 minutes after it is turned

 

 

 

back on.

 

 

 

 

 

 

The current interrupter

Press the RESET button located on the power cord plug.

 

 

device is tripped.

If the RESET button will not stay engaged, discontinue

 

 

 

use of the air conditioner and contact a qualified

 

 

 

service technician.

 

 

 

 

Air conditioner does

 

Airflow is restricted.

Make sure there are no curtains, blinds or furniture

not cool as it should

 

 

blocking the front of the air conditioner.

 

 

 

 

 

 

The temp control may

On models with touch pads: In the Cool mode, press the

 

 

not be set correctly.

Decrease pad.

 

 

 

• On models with control knobs, turn the temperature

 

 

 

knob to a higher number.

 

 

 

 

 

 

The air filter is dirty.

Clean the filter at least every 30 days.

 

 

 

See the Operating Instructions section.

 

 

 

 

 

 

The room may have been hot.

When the air conditioner is first turned on, you need

 

 

 

to allow time for the room to cool down.

 

 

 

 

 

 

Cold air is escaping.

Check for open furnace registers and cold air returns.

 

 

 

 

 

 

Cooling coils have iced up.

See “Air conditioner freezing up” below.

 

 

 

 

Air conditioner

 

Ice blocks the air flow

On models with control knobs, set the mode control at

freezing up

 

and stops the air conditioner

High Fan or High Cool with the Temp at 1 or 2.

 

 

from cooling the room.

• On models with touch pads, set the controls at High Fan

 

 

 

or High Cool and set the thermostat to a higher

 

 

 

temperature.

 

 

 

 

The remote control

 

The batteries are inserted

Check the position of the batteries. They should be

is not working

 

incorrectly.

inserted in the opposite (+) and (–) direction.

 

 

 

 

 

 

The batteries may be dead.

Replace the batteries.

 

 

 

 

Water drips outside

 

Hot, humid weather.

This is normal.

 

 

 

 

Water drips indoors

 

The air conditioner is not

For proper water disposal, make sure the air conditioner

 

 

tilted to the outside.

slants slightly from the case front to the rear.

 

 

 

 

Water collects in

 

Moisture removed from air

This is normal for a short period in areas with little

base pan

 

and drains into base pan.

humidity; normal for a longer period in very humid areas.

 

 

 

 

 

 

 

 

Normal Operating Sounds

 

You may hear a pinging noise caused by water

Water will collect in the base pan during

 

being picked up and thrown against the

high humidity or on rainy days. The water

 

condenser on rainy days or when the humidity

may overflow and drip from the outdoor side

 

is high. This design feature helps remove

of the unit.

 

moisture and improve efficiency.

The fan may run even when the compressor

 

 

12

You may hear the thermostat click when the

does not.

compressor cycles on and off.

 

Image 12
Contents 49-7514-1 11-05 JR Write the model and serial numbers here Model # Serial #Consumer Support Troubleshooting Tips Instructions Operating InstructionsInstallation Instructions Troubleshooting Tips Consumer SupportGe.com Instructions Consumer Support InstructionsTemperature Control Mode ControlCare and cleaning of the air conditioner SupportBefore YOU Begin Electrical RequirementsTools YOU will Need Installation Instructions Parts IncludedWindow Requirements Storm Window RequirementsPrepare the AIR Conditioner Install the AIR Conditioner in the Window Install a Support Bracket and the Foam TOP Window GasketPrepare the Window Troubleshooting Tips Problem Possible Causes What To DoNormal Operating Sounds GE Air Conditioner Warranty-One Year Limited Warranty Troubleshooting Tips Consumer SupportSafety Instructions Operating Instructions Installation InstructionsParts and Accessories Consumer Support GE Appliances WebsiteReal Life Design Studio Contact UsAcondicionadores de Aire ¡ADVERTENCIA Operación InstalaciónOperación Servicio al consumidorInstalación Servicio al consumidor Solucionar problemas SeguridadConsumidor Servicio alServicio al consumidor Solucionar problemas Control de modoControl de Temp Descripciones de enfriamientoSolucionar problemas Servicio Cuidado y limpieza del acondicionador de airePrecaución no Opere el Al consumidorAntes DE Iniciar Requisitos EléctricosHerramientas QUE Necesitará Partes IncluidasRequisitos Para LA Ventana Requisitos DE UNA Ventana DE TormentasPrepare EL Acondicionador DE Aire Prepare LA Ventana Prepare EL Acondicionador DE AireSolucionar problemas Problema Causas posibles Qué hacerSonidos de operación normales Seguridad Operación Nosotros reemplazaremosPara hacer un reclamo de garantía Lo que no está cubiertoServicio al consumidor Página Web de GE Appliances Piezas y accesoriosPóngase en contacto con nosotros