Nordyne M3RL Vent Table, Vent Termination Clearances for Direct Vent Furnaces

Page 15

 

 

 

 

 

*NOTES

 

 

MAXIMUM

 

1.

Subtract 3.5 ft. for each additional 3" 90 degree elbow.

 

APPLICATION

DIRECT VENT, DUAL

2.

Two45degreeelbowsareequivalenttoone90degreeelbow.

 

PIPE LENGTH (ft.)*

3.

One short radius elbow is equivalent to two long radius

 

 

 

 

 

 

 

 

elbows.

 

PVC,CPVC or ABS

Inlet/Outlet

 

 

4.

Donotincludeterminationelbowsincalculationofventlength.

 

SCH. 40 Pipe Size

3"

 

3"

5.

This table is applicable for elevations from sea level to 4000

 

Model M3RL 060

50

 

50

 

ft. Forhigherelevations,decreaseventpipelengthsby8%per

 

 

 

1000 ft. of altitude.

 

Model M3RL 080

50

 

50

 

 

 

6.

Only the above pipe materials are approved for use with these

 

 

 

 

 

 

condensingfurnaces.

 

 

 

 

 

 

 

Table 6. Vent Table

 

VENT TERMINAL

AIR SUPPLY INLET

AREA WHERE TERMINAL IS NOT PERMITTED

 

 

 

 

 

 

 

Canadian Installations1

 

US Installations2

A =

Clearance above grade, veranda, porch,

12 inches (30 cm)

 

12 inches (30 cm)

 

deck, or balcony

 

 

 

 

 

 

 

B =

Clearance to window or door that may be

6 inches (15 cm) for appliances 10,000

6 inches (15 cm) for appliances 10,000

 

opened

Btuh (3 kW), 12 inches (30 cm) for

Btuh (3 kW), 9 inches (23 cm) for

 

 

appliances > 10,000 Btuh (3 kW) and

appliances > 10,000 Btuh (3 kW) and

 

 

100,00 Btuh (30 kW), 36 inches (91 cm) for

50,000 Btuh (15 kW), 12 inches (30 cm) for

 

 

appliances >100,00 Btuh (30 kW)

appliances > 50,000 Btuh (15 kW)

 

 

 

 

 

C =

Clearance to permanently closed window

*

 

*

D =

Vertical clearance to ventilated soffit

 

 

 

 

located above the terminal within a

*

 

*

 

horizontal distance of 2 feet (61 cm) from

 

 

 

 

 

 

the center line of the terminal

 

 

 

E =

Clearance to unventilated soffit

*

 

*

F =

Clearance to outside corner

*

 

*

G =

Clearance to inside corner

*

 

*

H =

Clearance to each side of center line

3 feet (91 cm) within a height 15 feet

*

 

extended above meter/regulator assembly

above the meter/regulator assembly

 

 

I =

Clearance to service regulator vent outlet

3 feet (1.83 m)

 

*

J =

Clearance to nonmechanical air supply inlet

6 inches (15 cm) for appliances 10,000

6 inches (15 cm) for appliances 10,000

 

to building or the combustion air inlet to any

Btuh (3 kW), 12 inches (30 cm) for

Btuh (3 kW), 9 inches (23 cm) for

 

other appliance

appliances > 10,000 Btuh (3 kW) and

appliances > 10,000 Btuh (3 kW) and

 

 

100,00 Btuh (30 kW), 36 inches (91 cm) for

50,000 Btuh (15 kW), 12 inches (30 cm) for

 

 

appliances >100,00 Btuh (30 kW)

appliances > 50,000 Btuh (15 kW)

 

 

 

 

 

K =

Clearance to a mechanical air supply inlet

6 feet (1.83 m)

 

3 feet (91 cm) above if within 10 feet (3 m)

 

 

 

 

horizontally

 

 

 

 

 

L =

Clearance above paved sidewalk or paved

7 feet (2.13 m) †

 

*

 

driveway located on public property

 

 

 

 

 

 

 

 

 

 

 

M =

Clearance under veranda, porch deck, or

12 inches (30 cm) ‡

 

*

 

balcony

 

 

 

 

 

 

1In accordance with the current CSA B149.1 Natural Gas and Propane Installation Code

2In accordance with the current ANSI Z223.1 / NFPA 54 National Fuel Gas Code

A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.

‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.

*For clearances not specified in ANSI Z223.1 / NFPA 54 or CSA B149.1, the following statement shall be included:

“Clearance in accordance with local installation codes, and the requirements of the gas supplier and the manufacturer’s installation instructions.”

Figure 15. Vent Termination Clearances for Direct Vent Furnaces

15

Image 15
Contents Installation Instructions Page L 060 a a W Table of ContentsTop View Shipping WeightFurnace Specifications/Airflow Data GeneralGeneral Description Owner InformationManufacturer WARRANTY, OWNER’S Responsibilities Installation StandardsLocation Circulating AIR SupplyMinimum Clearances Return AIR Provisions Duct ConnectorsDucted Return AIR Closet or AlcoveDuct Connector Selection Duct InstallationAIR Distribution Systems Screw Down Platinum Series Installing Platinum Series 14 Round Duct ConnectorInstalling Screw Down Duct CON- Nector CUT Duct Opening Finger Tabbed onlyAlternate Attachment Methods Installing Finger Tabbed Duct CON- NectorsInstall Furnace Venting and Combustion AIR RequirementsGeneral Furnace Must not be Common Vented with Other Appliances Venting RequirementsVent Termination Clearances for Direct Vent Furnaces Vent TableVent Pipe Material Vent Pipe InstallationHorizontal Venting Downflow FurnaceHorizontal Venting Drainage of Condensate from Furnace Alternate Horizontal Vent InstallationGAS Supply and Piping Furnace with Condensate Drain Trap AssemblyTo Turn Off Fuel Supply to the Appliance ConversionLeak Check High Altitude DerateApproximate Orifice Size for Natural and LP Gases To Remove the Burner AssemblyTo Remove the Burner Orifices To Convert the Unit to the Alternate GasConvertible Pressure Regulator Cap Lighting and Adjustment of the ApplianceCompleting the Conversion Electrical WiringLine Voltage Wiring Type of Fuel Manifold PressureElectrical Data Low Voltage WiringSTART-UP and Adjustments Start-Up ProcedureVentilation Shut Down Procedure Sequence of OperationVerifying Firing Rate Verifying Burner Operation Verifying Operation of the Supply Air Limit SwitchDescription of Components Gas Flow RateAir Filter MaintenanceAccessory Kits Combustion Air and Vent SystemBlower Compartment Condensate Drain AssemblySystem Operation Information LubricationFurnace Fails to Operate Cooling ModeM3 Downflow Furnace Downflow Furnace Wiring Diagram Page Fuel Type INSTALLATION/PERFORMANCE Check List¢7082197¤

M3RL specifications

The Nordyne M3RL is a high-efficiency gas furnace designed for residential heating applications, characterized by its robust performance and advanced technologies. It is part of Nordyne's distinguished lineup, which emphasizes reliability and comfort in home heating systems. The M3RL model is particularly notable for its focus on energy efficiency, making it an attractive option for homeowners looking to reduce their energy expenses while maintaining optimal heating levels.

One of the standout features of the Nordyne M3RL is its high Annual Fuel Utilization Efficiency (AFUE) rating, which often exceeds 80%. This efficient design ensures that more of the fuel consumed is converted into usable heat for the home. By employing a variable-speed blower, the M3RL enhances comfort by allowing for more precise control over air circulation, contributing to better temperature consistency throughout the living space.

The M3RL utilizes advanced multi-stage heating technology, allowing the system to operate at different capacities depending on the heating demand. This means it can run at lower settings during milder weather, which not only saves energy but also reduces wear and tear on the equipment, extending its lifespan. The furnace also includes a reliable ignition system that ensures quick and safe starts, eliminating the inefficiencies associated with older pilot light systems.

Another important characteristic of the Nordyne M3RL is its acoustical insulation, which minimizes operational noise. The quiet operation is particularly valued in residential settings, where noise pollution can be disruptive. Additionally, the furnace features a compact design, making it easy to install in a variety of spaces, including tight basements or utility rooms.

The M3RL model is also equipped with a smart control system that interfaces seamlessly with modern thermostats, offering homeowners the ability to program their heating schedules and optimize energy usage. This integration with smart home technology positions the M3RL not just as a heating solution, but as a component of a more comprehensive home energy management system.

In conclusion, the Nordyne M3RL gas furnace represents a blend of efficiency, advanced technology, and user-friendly features. Its high AFUE rating, multi-stage heating capability, quiet operation, and smart technology integration make it a reliable choice for homeowners aiming to enhance their comfort while minimizing energy costs. This furnace is a testament to Nordyne's commitment to innovation in the HVAC industry.