OPTIONAL WIRING
❒When wiring to additional standard fixture only: Strip the motion sensor's red wire and connect to the standard light's black wire. Connect all white wires together. Total fixture ratings must not exceed 360W (3.0 A.).
NOTE: All wiring between fixtures should be run in accordance with the National Elec- trical Code (Canadian Electrical Code in Canada) through conduit or another ac- ceptable means. Contact a qualified electrician if there is any question as to the suitability of the system.
❒This fixture is provided with a sensor rated for 360 W. Since the fixture is only rated 100 W, 260 W of additional load may be controlled by this sensor.
❒When determining what a fixture is rated for, do not simply look at the rating on the lamp in the fixture. Look at the marking which specifies the maximum lamp watt- age for which the fixture is suitable.
❒Once you have selected the fixtures to be connected and determined their maximum ratings, add these ratings up. For instance, if you have 3 fixtures rated 100 W, 150 W, and 75 W respec- tively, you have a total load of 325 W.
RED to
BLACKBLACK
WHITE (Standard)
Wiring to Motion Light &
Standard Fixture
MasterSlave
BLACK
RED
BLACK
WHITE
Wiring to Control One Motion Sensing Lantern (Slave) from Another (Master)
COMPLETE THE
INSTALLATION
❒Stuff the wires into the junction box. Make sure none of the wires get pinched.
❒Install one 100 W max. light bulb.
❒Install the fixture top. Secure with decorative screws.
❒Caulk fixture mounting surface with silicone weather sealant. You may want to wait until you have completed the tests and adjustments on page 4.
Slide the fixture onto the mounting screws and tighten nuts.