Heath Zenith 598-1041-04 Testing, Specifications, Turn on the circuit breaker and light switch

Page 4

TESTING

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 11/2 minute warm up period before it will detect motion. When first turned on or when switching modes wait 11/2 minutes.

Switch the on-time to TEST position and Dual Brite™ switch to the OFF position.

TEST 1 5 10 MIN

OFF 3 6 DUSK TO

ON-TIME

HOUR DAWN

Avoid locations that will cause the

control to "see":

Objects that change temperature rapidly, such as heating vents and air condition- ers. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflectinglightmaytriggertheshut-offfeature. Do not point other lights at the sensor.

180°

1.8 m

 

9.1 m

Maximum

Maximum

Range

Coverage Angle

The detector is less sensitive to motion directly towards it and more sensitive to across motion.

MotionMotion

Sensor

Least Sensitive

Most Sensitive

Walk through the coverage area noting where you are when the lights turn on.

If you need to change the sensitivity, temporarily remove the fixture and make the adjustment. Too much sensitivity may cause false triggering in some installations.

Set the amount of TIME you want the light to stay on after motion is detected. (1, 5, or 10 minutes).

TEST 1 5 10 MIN

OFF 3 6 DUSK TO

 

HOUR DAWN

Set the amount of time after dusk you want the lights on accent level.

SPECIFICATIONS

Range . . . . . . . . . . . . . Up to 30 ft. (9.1 m) [varies

with surrounding temperature].

Sensing Angle . . . . . . . Up to 180°

Electrical Load . . . . . . Up to 100 Watt Maximum Incandescent

Sensor Capacity . . . . . Up to 360 Watt (3.0 A.) Maximum

Power Requirements . 120 VAC, 60 Hz Operating Modes . . . . TEST, AUTO and

MANUAL MODE Time Delay . . . . . . . . . 1 , 5, 10 minutes Dual Brite™ timer . . . . Off, 3, 6 hrs, to dawn

DESA Specialty Products™ reserves the right to discontinue products and to change specifications at anytimewithoutincurringanyobligationtoincorporate new features in products previously sold.

4

598-1041-04

Image 4
Contents Features Some codes require installation by a qualified electricianOperation RequirementsTurn power off at the circuit breaker or fuse InstallationwiringBlack to black White to white Complete Installation Optional WiringWiring to Motion Light Standard Fixture Testing SpecificationsTurn on the circuit breaker and light switch Avoid locations that will cause Control to seeTroubleshooting Guide No Service Parts Available for this ProductFuncionamiento CaracterísticasAutom AdornoInstalacion CableadoDesconecte la energía en el cortacircuito Negro to negro Blanco to blancoConexion Alterna Complete LA InstalacionPrueba EspecificacionesGuia DE Investigacion DE Averias No hay piezas de servicio disponibles para este productoFonctionnement ExigencesMéthode de mise à la terre recommandée CâblageOu au fusible Une lanterne à détecteur de mouvementComplétez Linstallation Câblage FacultatifFiche Technique EssaisÉviter de pointer l’appareil Guide DE Dépannage Aucune pièce de rechange n’est disponible pour ce produit598-1041-04