Broan ERV90HCT, HRV90HT installation instructions 457 MM 152 MM

Page 16

3.INSTALLATION (CONT’D)

3.9INSTALLING 2 EXTERIOR HOODS

Choose an appropriate location to install the exterior hoods:

There must be a minimum distance of 6 feet (1.8 m) between the hoods to avoid cross-contamination

There must be a minimum distance of 18 inches (457 mm) from the ground

!WARNING

Make sure the intake hood is at least 6 feet (1.8 m) away (or more, as per applicable building codes or standards) from sources of contamination such as:

High efficiency furnace vent

Any exhaust from a combustion source

Gas meter exhaust, gas barbecue-grill

Garbage bin

Refer to figure below for connecting insulated ducts to the exterior hoods. An “Anti-gust intake hood” should be installed in regions where a lot of snow is expected to fall.

EXHAUST HOOD

18”

(457 MM)

6” Ø

(152 MM)

INTAKE HOOD

6’

18”

(1.8 M)

(457 MM)

6’

(1.8 M)

OPTIONAL

18” (457 MM)

DUCT LOCATION

TAPE AND DUCT TIE

VD0028

- 16 -

Image 16
Contents Installation Instructions HRV90H and ERV90HC About this Manual About These Units LimitationTable of Contents Technical Data 42 lb 19 kgIT 5 127 MM Ducts 12 MMTechnical Data CONT’D HRV UnitsHRV Typical Installations Typical Installations CONT’D Installation Installation CONT’D Make sure the unit is levelStale air exhaust ductwork Fresh air distribution ductworkMethod 2 Return side connection Method 1 Supply side connectionFurnace/air handler blower operation see Section Stale air intake Fresh air distributionInsulated flexible ducts Do not use screws to connect the rigid ducts to the portsRigid ducts 457 mm Xmas Tree PIN 457 MM 152 MM Controls AvertissementControls CONT’D AIN WallElectrical Connection to the Furnace For a furnace connected to a cooling system6WIRING DiagramBalancing the Unit Connecting the Drain HRV Units only Maintenance Maintenance CONT’D Service Parts HRV90HS HRV90HT ERV90HCS ERV90HCTTroubleshooting Problems Possible causes You should try thisPiezas Solución DE Problemas Problemas Causas posibles Debería hacer estoManual DE Instalación Modelos HRV90H Y ERV90HC Acerca DE Este Manual Acerca DE Estos Aparatos LimitaciónAdvertancia CuidadoÍndice Datos Técnicos Ubos DE 5 127 MMDatos Técnicos Continuación Rendimiento DE VentilaciónDimensiones Instalaciones Habituales EncendidoInstalaciones Habituales Continuación Instalación Tubos de extracción de aire viciado Compruebe que el aparato esté a nivelTubos de distribución del aire puro Método 1 Conexión por el lado de la alimentación Método 2 Conexión por el lado de retornoAdmisión de aire viciado Distribución del aire puroTubos flexibles aislados 457 mm VD0087TORNILLO 18 457 MM Controles Control IntegradoControles Continuación Cableado de interbloqueo estándar de la caldera Conexión Eléctrica CON LA CalderaCableado de interbloqueo alternativo de la caldera 6DIAGRAMADE Cableados AparatoAntes de efectuar cualquier ReparaciónEquilibrado DEL Aparato Ponga el aparato en velocidad altaConexión DEL Desagüe Aparatos HRV Únicamente Mantenimiento Maintenimiento SemestralMantenimiento Continuación Piezas Solución DE Problemas
Related manuals
Manual 52 pages 11.89 Kb

HRV90HT, ERV90HCT specifications

The Broan ERV90HCT and HRV90HT are remarkable energy recovery ventilators designed to enhance indoor air quality while promoting energy efficiency in residential settings. Both models are built with innovative technologies that meet the demands of modern homes, ensuring a comfortable living environment.

One of the standout features of the Broan ERV90HCT and HRV90HT is their energy recovery capabilities. They efficiently exchange stale indoor air with fresh outdoor air, recovering up to 90% of the energy that would otherwise be lost. This process not only improves air quality but also helps in reducing heating and cooling costs, making them an excellent investment for energy-conscious homeowners.

Another significant characteristic of both models is their quiet operation. Equipped with advanced fan technology, the ERV90HCT and HRV90HT work at minimal noise levels, ensuring a peaceful indoor atmosphere. Whether in a bedroom, living room, or office, occupants can enjoy the benefits of fresh air without disruptive noise.

The units are designed with user-friendly controls that make operation simple and intuitive. Homeowners can easily adjust settings to optimize airflow based on current needs, whether it’s high ventilation during peak usage times or lower settings for quieter moments. Additionally, the units come with a built-in timer, allowing for customizable operation schedules.

Durability is another hallmark of the Broan ERV90HCT and HRV90HT. Constructed with high-quality materials, these ventilators are designed for long-lasting performance. Furthermore, their compact design allows for flexible installation options, making them suitable for various home layouts and sizes.

The ERV90HCT features a heat recovery system, making it ideal for climates that experience significant temperature fluctuations, while the HRV90HT is tailored for those residing in colder regions. Both units utilize an efficient balanced ventilation system, ensuring that airflow is evenly distributed throughout the home.

In summary, the Broan ERV90HCT and HRV90HT are top-tier energy recovery ventilators that prioritize comfort, efficiency, and air quality. With their energy recovery capabilities, quiet operation, user-friendly controls, durability, and flexible installation options, they stand out in the market as excellent solutions for maintaining a healthy home environment. Whether seeking to reduce energy costs or improve indoor air quality, these models deliver on all fronts, making them a worthy addition to any household.