Broan HRV90HT, ERV90HCT installation instructions Controls, Avertissement

Page 17

4.CONTROLS

4.1INTEGRATED CONTROL

All units are equipped with an integrated control, located under the unit, in front of the electrical compartment. Use the push button (1) to control the unit. The LED (2) will then show which mode the unit is in.

Refer to table below to see how to operate the unit using its integrated control.

WARNING

AVERTISSEMENT

Risk of electric shock. Before performing

Danger d’électrocution. Débranchez

any maintenance or servicing, always

toujours l’appareil avant d’entreprendre

disconnect the unit from its power source.

des travaux d’entretien ou de réparation.

 

 

 

 

 

 

CAUTION

 

 

ATTENTION

 

 

Unscrew both screws to open the electrical

Dévisser les deux vis pour ouvrir le compartiment

 

compartment. To completely remove, detach

électrique. Pour retirer complètement, le

 

 

 

from its retention wire inside.

détacher de son fil de rétention intérieur.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No light

OFF or remote controled

 

 

 

 

 

 

 

 

 

 

Amber light

LOW speed

 

 

 

 

 

 

 

 

 

 

Green ligh

HIGH speed

 

 

 

 

 

 

 

 

 

 

Blinking light

See User Manual

 

 

 

 

 

 

 

 

 

 

Sans lumière

Arrêté ou contrôlé

 

 

 

 

 

 

 

 

 

 

 

par contrôle mural

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lumière ambre

Basse vitesse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lumière verte

Haute vitesse

 

 

 

 

 

 

 

 

 

 

 

 

 

Clignotant

Voir guide d’utilisation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VD0182

1

2

PRESS ON PUSH BUTTON

LED COLOR

RESULTS

ONCE

AMBER

UNIT IS ON LOW SPEED

TWICE

GREEN

UNIT IS ON HIGH SPEED

THREE TIMES

NO LIGHT

UNIT IS OFF

If a problem occurs during the unit operation, its integrated control LED (2) will blink. The color of the blinking light depends on the type of error detected. Refer to Section 11 Troubleshooting on last page for further details.

4.1.1BOOT SEQUENCE

The unit boot sequence is similar to a personnal computer boot sequence. Each time the unit is plugged in after being unplugged, or after a power failure, the unit will perform a 30-second booting sequence before starting to operate. During the booting sequence, the integrated control LED will light GREEN or AMBER for 5 seconds, and then will shut off for 2 seconds. After that, the LED will light RED for the rest of the booting sequence. During this RED light phase, the unit is checking and resetting the motorized damper position. Once the motorized damper position is completely set, the RED light turns off and the booting sequence is done.

NOTE: No command will be taken until the unit is fully booted.

4.2ELECTRICAL CONNECTION TO OPTIONAL WALL CONTROLS

For more convenience, this unit can also be controlled using an optional main wall control.

NOTES: 1. The integrated control must be turned OFF to use an optional main control.

2. If an optional auxiliary control is used, if activated, this auxiliary control will override the optional main control.

!WARNING

Always disconnect the unit before making any connections. Failure in disconnecting power could result in electrical shock or damage of the wall control or electronic module inside the unit.

CAUTION

Never install more than one optional main wall control per unit. Make sure that the wires do not short-circuit between themselves or by touching any other components on the wall control. Avoid poor wiring connections. To reduce electrical interference (noise) potential, do not run wall control wiring next to control contactors or near light dimming circuits, electrical motors, dwelling/building power or lighting wiring, or power distribution panel.

Use the terminal connector included in the installation kit to perform the electrical connection for main and optional wall controls. Check if all wires are correctly inserted in their corresponding holes in the terminal block. (A wire is correctly inserted when its orange receptacle is lower than another one without wire. On picture beside, wire A is correctly inserted, but not wire B.)

AB

VE0106

- 17 -

Image 17
Contents Installation Instructions HRV90H and ERV90HC About These Units Limitation About this ManualTable of Contents 42 lb 19 kg Technical DataIT 5 127 MM Ducts 12 MMHRV Units Technical Data CONT’DHRV Typical Installations Typical Installations CONT’D Installation Make sure the unit is level Installation CONT’DStale air exhaust ductwork Fresh air distribution ductworkFurnace/air handler blower operation see Section Method 1 Supply side connectionMethod 2 Return side connection Fresh air distribution Stale air intakeRigid ducts Do not use screws to connect the rigid ducts to the portsInsulated flexible ducts 457 mm Xmas Tree PIN 457 MM 152 MM Avertissement ControlsAIN Wall Controls CONT’DFor a furnace connected to a cooling system Electrical Connection to the FurnaceDiagram 6WIRINGBalancing the Unit Connecting the Drain HRV Units only Maintenance Maintenance CONT’D HRV90HS HRV90HT ERV90HCS ERV90HCT Service PartsProblems Possible causes You should try this TroubleshootingPiezas Problemas Causas posibles Debería hacer esto Solución DE ProblemasManual DE Instalación Modelos HRV90H Y ERV90HC Acerca DE Estos Aparatos Limitación Acerca DE Este ManualAdvertancia CuidadoÍndice Ubos DE 5 127 MM Datos TécnicosRendimiento DE Ventilación Datos Técnicos ContinuaciónDimensiones Encendido Instalaciones HabitualesInstalaciones Habituales Continuación Instalación Tubos de distribución del aire puro Compruebe que el aparato esté a nivelTubos de extracción de aire viciado Método 2 Conexión por el lado de retorno Método 1 Conexión por el lado de la alimentaciónDistribución del aire puro Admisión de aire viciadoTubos flexibles aislados 457 mm VD0087TORNILLO 18 457 MM Control Integrado ControlesControles Continuación Cableado de interbloqueo alternativo de la caldera Conexión Eléctrica CON LA CalderaCableado de interbloqueo estándar de la caldera Aparato 6DIAGRAMADE CableadosAntes de efectuar cualquier ReparaciónPonga el aparato en velocidad alta Equilibrado DEL AparatoConexión DEL Desagüe Aparatos HRV Únicamente Maintenimiento Semestral MantenimientoMantenimiento Continuación Piezas Solución DE Problemas
Related manuals
Manual 52 pages 11.89 Kb

HRV90HT, ERV90HCT specifications

The Broan ERV90HCT and HRV90HT are remarkable energy recovery ventilators designed to enhance indoor air quality while promoting energy efficiency in residential settings. Both models are built with innovative technologies that meet the demands of modern homes, ensuring a comfortable living environment.

One of the standout features of the Broan ERV90HCT and HRV90HT is their energy recovery capabilities. They efficiently exchange stale indoor air with fresh outdoor air, recovering up to 90% of the energy that would otherwise be lost. This process not only improves air quality but also helps in reducing heating and cooling costs, making them an excellent investment for energy-conscious homeowners.

Another significant characteristic of both models is their quiet operation. Equipped with advanced fan technology, the ERV90HCT and HRV90HT work at minimal noise levels, ensuring a peaceful indoor atmosphere. Whether in a bedroom, living room, or office, occupants can enjoy the benefits of fresh air without disruptive noise.

The units are designed with user-friendly controls that make operation simple and intuitive. Homeowners can easily adjust settings to optimize airflow based on current needs, whether it’s high ventilation during peak usage times or lower settings for quieter moments. Additionally, the units come with a built-in timer, allowing for customizable operation schedules.

Durability is another hallmark of the Broan ERV90HCT and HRV90HT. Constructed with high-quality materials, these ventilators are designed for long-lasting performance. Furthermore, their compact design allows for flexible installation options, making them suitable for various home layouts and sizes.

The ERV90HCT features a heat recovery system, making it ideal for climates that experience significant temperature fluctuations, while the HRV90HT is tailored for those residing in colder regions. Both units utilize an efficient balanced ventilation system, ensuring that airflow is evenly distributed throughout the home.

In summary, the Broan ERV90HCT and HRV90HT are top-tier energy recovery ventilators that prioritize comfort, efficiency, and air quality. With their energy recovery capabilities, quiet operation, user-friendly controls, durability, and flexible installation options, they stand out in the market as excellent solutions for maintaining a healthy home environment. Whether seeking to reduce energy costs or improve indoor air quality, these models deliver on all fronts, making them a worthy addition to any household.