Broan ERV90HCT, HRV90HT installation instructions Dimensiones

Page 34

1. DATOS TÉCNICOS (CONTINUACIÓN)

1.5DIMENSIONES

1.5.1 DIMENSIONES DE LOS APARATOS CON ABERTURAS LATERALES

HRV

6”

(152 mm)

4” (102 mm)

27 1/16” (688 mm)

22 9/16” (574 mm)

 

19 13 /16” (503 mm)

 

13¾”

12 3

/16

(310 mm)

(349 mm)

 

 

2” (51 mm)

VK0055A

4” (102 mm)

6”

(152 mm)

ERV

27 1/16” (688 mm)

22 9 /16” (574 mm)

19 13 /16” (503 mm)

12 3 /16

(310 mm)

2” (51 mm)

VK0057A

1.5.2DIMENSIONES DE LOS APARATOS CON ABERTURAS EN LA PARTE SUPERIOR

1913 16

(503 mm)

HRV

4’’ (102 mm)

6’’ (152 mm)

22 9 16” (574 mm)

23¾” (603 mm)

1913 16

(503 mm)

ERV

4’’ (102 mm)

6’’ (152 mm)

22 9 16” (574 mm)

23¾” (603 mm)

2½”

(64 mm)

16¼”

12

3 16

(413 mm)

(310 mm)

 

2½”

(64 mm)

16¼”

12

3 16

(413 mm)

(310 mm)

 

VK0058A

VK0056A

1.6CONTROLES Y POSIBILIDADES DE CONEXIÓN

CONTROL PRINCIPAL

CONTROLES AUXILIARES

POSIBILIDAD DE CONEXIÓN

• VT4W

• TEMPORIZADOR DE BOTÓN PULSADOR

• INTERBLOQUEO DE ARMARIO DE TRATAMIENTO

 

DE 20 MINUTOS

DE AIRE (SE USA CON SISTEMAS DE AIRE

 

• TEMPOSIZADOR MECÁNICO DE 60 MINUTOS

FORZADO)

 

• HUMIDITY CONTROL

 

- 6 -

Image 34
Contents Installation Instructions HRV90H and ERV90HC About this Manual About These Units LimitationTable of Contents IT 5 127 MM Ducts Technical Data42 lb 19 kg 12 MMTechnical Data CONT’D HRV UnitsHRV Typical Installations Typical Installations CONT’D Installation Stale air exhaust ductwork Installation CONT’DMake sure the unit is level Fresh air distribution ductworkMethod 2 Return side connection Method 1 Supply side connectionFurnace/air handler blower operation see Section Stale air intake Fresh air distributionInsulated flexible ducts Do not use screws to connect the rigid ducts to the portsRigid ducts 457 mm Xmas Tree PIN 457 MM 152 MM Controls AvertissementControls CONT’D AIN WallElectrical Connection to the Furnace For a furnace connected to a cooling system6WIRING DiagramBalancing the Unit Connecting the Drain HRV Units only Maintenance Maintenance CONT’D Service Parts HRV90HS HRV90HT ERV90HCS ERV90HCTTroubleshooting Problems Possible causes You should try thisPiezas Solución DE Problemas Problemas Causas posibles Debería hacer estoManual DE Instalación Modelos HRV90H Y ERV90HC Advertancia Acerca DE Este ManualAcerca DE Estos Aparatos Limitación CuidadoÍndice Datos Técnicos Ubos DE 5 127 MMDatos Técnicos Continuación Rendimiento DE VentilaciónDimensiones Instalaciones Habituales EncendidoInstalaciones Habituales Continuación Instalación Tubos de extracción de aire viciado Compruebe que el aparato esté a nivelTubos de distribución del aire puro Método 1 Conexión por el lado de la alimentación Método 2 Conexión por el lado de retornoAdmisión de aire viciado Distribución del aire puroTubos flexibles aislados 457 mm VD0087TORNILLO 18 457 MM Controles Control IntegradoControles Continuación Cableado de interbloqueo estándar de la caldera Conexión Eléctrica CON LA CalderaCableado de interbloqueo alternativo de la caldera Antes de efectuar cualquier 6DIAGRAMADE CableadosAparato ReparaciónEquilibrado DEL Aparato Ponga el aparato en velocidad altaConexión DEL Desagüe Aparatos HRV Únicamente Mantenimiento Maintenimiento SemestralMantenimiento Continuación Piezas Solución DE Problemas
Related manuals
Manual 52 pages 11.89 Kb

HRV90HT, ERV90HCT specifications

The Broan ERV90HCT and HRV90HT are remarkable energy recovery ventilators designed to enhance indoor air quality while promoting energy efficiency in residential settings. Both models are built with innovative technologies that meet the demands of modern homes, ensuring a comfortable living environment.

One of the standout features of the Broan ERV90HCT and HRV90HT is their energy recovery capabilities. They efficiently exchange stale indoor air with fresh outdoor air, recovering up to 90% of the energy that would otherwise be lost. This process not only improves air quality but also helps in reducing heating and cooling costs, making them an excellent investment for energy-conscious homeowners.

Another significant characteristic of both models is their quiet operation. Equipped with advanced fan technology, the ERV90HCT and HRV90HT work at minimal noise levels, ensuring a peaceful indoor atmosphere. Whether in a bedroom, living room, or office, occupants can enjoy the benefits of fresh air without disruptive noise.

The units are designed with user-friendly controls that make operation simple and intuitive. Homeowners can easily adjust settings to optimize airflow based on current needs, whether it’s high ventilation during peak usage times or lower settings for quieter moments. Additionally, the units come with a built-in timer, allowing for customizable operation schedules.

Durability is another hallmark of the Broan ERV90HCT and HRV90HT. Constructed with high-quality materials, these ventilators are designed for long-lasting performance. Furthermore, their compact design allows for flexible installation options, making them suitable for various home layouts and sizes.

The ERV90HCT features a heat recovery system, making it ideal for climates that experience significant temperature fluctuations, while the HRV90HT is tailored for those residing in colder regions. Both units utilize an efficient balanced ventilation system, ensuring that airflow is evenly distributed throughout the home.

In summary, the Broan ERV90HCT and HRV90HT are top-tier energy recovery ventilators that prioritize comfort, efficiency, and air quality. With their energy recovery capabilities, quiet operation, user-friendly controls, durability, and flexible installation options, they stand out in the market as excellent solutions for maintaining a healthy home environment. Whether seeking to reduce energy costs or improve indoor air quality, these models deliver on all fronts, making them a worthy addition to any household.