Rinnai RHFE-431WTA installation manual

Page 14

NOTICE BEFORE INSTALLATION

The heater must be installed by a qualified service person according to this installation instruction.

Check your local building codes for the proper method of installation. In the case of absence of local codes, this heater should be installed in accordance with the National Fuel Gas Code ANSI Z2231.

Check local codes or, in the absence of local codes, the current CAN/CGAB149 INSTALLATION CODE.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.

“WARNING” Do not operate appliance with the panel(s) removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified service person.

INSTALLATION AND REPAIR SHOULD BE DONE BY A QUALIFIED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A QUALIFIED SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE UNIT BE KEPT CLEAN.

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1, if an external electrical source is utilized.

WARNING: THIS APPLIANCE IS EQUIPPED WITH A THREEPRONG (GROUNDING) PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREEPRONG RECEPTACLE. Do not cut or remove the grounding prong from the plug.

This gas appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance.

When the appliance is installed directly on carpeting, tile or other combustible material other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.

Rinnai recommends a dedicated electrical circuit.

Appliance input ratings are based on sea level operation and need not be changed for operation up to 2,000 feet elevation. For operation at elevations above 2,000 feet, manufactured to specified deration conditions for Canada and the United States.

– 12 –

Image 14
Contents RHFE-431WTA Table of Contents Features of the RHFE-431WTA Units Safety DevicesIncluded in Carton Technical DataGAS Conversion Specifications Page Dimensions General InformationSpecifications SpecificationsAIR Supply Safety Points Gasoline Getting to Know Your NEW RHFE-431 Control Panel Mode OperationTemperatures LED DisplayCUT-AWAY Diagram Page Installation Instructions GAS Connection Wall Mounting Brackets Flue Manifold PositionSecure Heater to Wall Vent Termination Clearances WindowordoorthatmaybeopenedLocation / Clearances Flue SizesFIT Back Covers Sides only Standard Installation of Flue ManifoldSnow Areas Sleeve and Manifold Installation Method for Standard WallsProvided to compensate for weather board angle Locking Clamp Screw Clamp and Insulation Fitting UnitAIR Inlet Hose Instruct Customer on USE of Heater Operating Instructions To Open the Control Panel Setting the ClockSetting the Current Time & DAY To turn the heater OFF Operating the Heater ManuallyTo turn the heater on OFF Programing the Weekly Timers 3 4 OFF Auto Frost Man Override Select Progr Clock Temp RPrograming the Timers Example Example SchedulePrograming the Timers Example TimersTo exit the Weekly Timer Review mode Weekly Timer Review FunctionTo enter the Weekly Timer Review mode Factory PRE-SET Program Your Weekly Timer ProgramPoints to remember when writing your program Points to consider before writing your programFollow the steps below to operate the timers Operating the TimersReturning to Manual Mode To turn on the Override function If the current timerOverride Function Period is on heating Period is OFFFrost Protection To turn off the Frost ProtectionTo turn off the Economy Mode Energy Saving ModeTo turn on the Economy mode Economy Mode InformationTo deactivate the Function Lock Function LockTo activate the Function Lock Testing Unit Fault-Failure ProcedureAt Ignition PRE-SERVICE CheckWhen the unit is turned off During CombustionTrouble Shooting Error Messages Code Displayed Fault RemedyMaintenance / Service Maintenance SuggestionsWiring Diagram Warranty Information Consumer SupportHeat Exchanger Year of Failure Allowance Schematic Diagram Page Page Page Page Parts List Page Page Page Part Name QTY Remarks Flow Diagram Rank Parts Name Parts no QTY Remarks Vent KIT Names and Numbers of Parts Installing AN Extension KIT How to connect exhaust pipesTo prevent water condensation How to connect air intake hoseMaximum extendable length Qualified Installing Agency Page 431F-1720×0800 2008.09

RHFE-431WTA specifications

The Rinnai RHFE-431WTA is a sophisticated gas heater designed to provide efficient and reliable warmth for residential spaces. This innovative heating solution combines advanced technologies with user-friendly features, making it an ideal choice for homeowners seeking comfort without compromising on energy efficiency.

One of the standout characteristics of the RHFE-431WTA is its sleek, compact design. This gas heater can be easily integrated into any room, thanks to its modern aesthetics and low-profile build. Its dimensions allow it to fit snugly into various interior layouts, ensuring that it occupies minimal space while delivering maximum heat output.

A key feature of the RHFE-431WTA is its impressive heating capacity. With the ability to produce up to 4.2 kilowatts of heat, this unit can effectively warm spaces of various sizes. Whether it’s a cozy living area or a larger family room, the heater can adapt to your needs, providing comfortable temperatures even in the coldest months.

The Rinnai RHFE-431WTA also boasts advanced fan technology that distributes heat evenly throughout the room, eliminating cold spots and ensuring consistent warmth. Its whisper-quiet operation enhances the user experience, allowing you to enjoy a tranquil environment without the distraction of noisy heating equipment.

Energy efficiency is another major highlight of the RHFE-431WTA. This unit features a high energy efficiency rating, which not only reduces utility costs but also minimizes environmental impact. Its advanced combustion technology ensures that gas is burned optimally, contributing to lower emissions and a more sustainable heating solution.

The heater also includes an intelligent control system. With a user-friendly interface, homeowners can easily adjust settings to suit their comfort preferences. The unit comes equipped with a digital display that provides real-time information on temperature settings, operation modes, and timers, allowing for precise control over your heating needs.

Safety is a top priority for Rinnai, and the RHFE-431WTA is no exception. The heater is equipped with multiple safety features, including an automatic shut-off mechanism that activates if it detects any irregularities during operation. This ensures peace of mind for users, particularly in households with children or pets.