Rinnai RHFE-431WTA Operating the Heater Manually, To turn the heater on, To turn the heater OFF

Page 27

OPERATING THE HEATER MANUALLY

To turn the heater ON:

1Press the “ON/OFF” button.

Check to see if the “Man” or “Auto”

2indicator is displayed:

If the “Auto” indicator is displayed then press the “Auto” button. The indicator will change to “Man”.

Go to Step 3.

ON/OFF

 

 

indicator

 

 

 

Set

Room

ON

Frost

Eco

 

pm

Auto

 

 

 

 

 

 

 

 

Tu

 

 

 

 

 

1

 

 

Override

Auto

ON/OFF

 

 

 

 

 

indicator

 

 

 

If the “Man” indicator is displayed go to Step 3.

3

Select the desired room temperature

by pressing the “” or “” buttons.

Set

Room

pm

ON

Man

 

Tu

 

Set

Room

pm

ON

Man

 

Tu

 

Programming

Clock Select Timers

The heater will start and run for 90 seconds so that it can check the room temperature (the indicator will show).

If the room temperature is lower than the pre-set or desired temperature the heater will continue to run.

If the room temperature is higher than the pre-set or desired temperature, the heater will go into “stand- by” mode, and will start when the room temperature falls below the pre-set temperature.

If the heater does not ignite on initial use, this may be due to air remaining in the gas supply line. The spark generator will only continue for 15 seconds. After this it will be necessary to press the ON/OFF button OFF, then ON again.

To turn the heater OFF:

1

Press the “ON/OFF” button.

Frost

Eco

 

pm

 

 

Tu

 

 

Override

Auto

ON/OFF

DO NOT turn heater off by unplugging the power cord.

The convection fan will continue to run until the appliance cools.

– 25 –

Image 27
Contents RHFE-431WTA Table of Contents Safety Devices Features of the RHFE-431WTA UnitsTechnical Data GAS Conversion SpecificationsIncluded in Carton Page General Information DimensionsSpecifications SpecificationsAIR Supply Safety Points Gasoline Getting to Know Your NEW RHFE-431 LED Display Mode OperationTemperatures Control PanelCUT-AWAY Diagram Page Installation Instructions GAS Connection Flue Manifold Position Secure Heater to WallWall Mounting Brackets Windowordoorthatmaybeopened Vent Termination ClearancesFlue Sizes Location / ClearancesStandard Installation of Flue Manifold Snow AreasFIT Back Covers Sides only Method for Standard Walls Sleeve and Manifold InstallationProvided to compensate for weather board angle Fitting Unit AIR Inlet HoseLocking Clamp Screw Clamp and Insulation Instruct Customer on USE of Heater Operating Instructions Setting the Clock Setting the Current Time & DAYTo Open the Control Panel Operating the Heater Manually To turn the heater onTo turn the heater OFF OFF 3 4 OFF Auto Frost Man Override Select Progr Clock Temp R Programing the Weekly TimersExample Schedule Programing the Timers ExampleTimers Programing the Timers ExampleWeekly Timer Review Function To enter the Weekly Timer Review modeTo exit the Weekly Timer Review mode Points to consider before writing your program Your Weekly Timer ProgramPoints to remember when writing your program Factory PRE-SET ProgramOperating the Timers Returning to Manual ModeFollow the steps below to operate the timers Period is on heating Period is OFF If the current timerOverride Function To turn on the Override functionTo turn off the Frost Protection Frost ProtectionEconomy Mode Information Energy Saving ModeTo turn on the Economy mode To turn off the Economy ModeFunction Lock To activate the Function LockTo deactivate the Function Lock Fault-Failure Procedure Testing UnitDuring Combustion PRE-SERVICE CheckWhen the unit is turned off At IgnitionTrouble Shooting Code Displayed Fault Remedy Error MessagesMaintenance Suggestions Maintenance / ServiceWiring Diagram Consumer Support Warranty InformationHeat Exchanger Year of Failure Allowance Schematic Diagram Page Page Page Page Parts List Page Page Page Part Name QTY Remarks Flow Diagram Rank Parts Name Parts no QTY Remarks Vent KIT Names and Numbers of Parts How to connect exhaust pipes Installing AN Extension KITHow to connect air intake hose Maximum extendable lengthTo prevent water condensation Qualified Installing Agency Page 431F-1720×0800 2008.09

RHFE-431WTA specifications

The Rinnai RHFE-431WTA is a sophisticated gas heater designed to provide efficient and reliable warmth for residential spaces. This innovative heating solution combines advanced technologies with user-friendly features, making it an ideal choice for homeowners seeking comfort without compromising on energy efficiency.

One of the standout characteristics of the RHFE-431WTA is its sleek, compact design. This gas heater can be easily integrated into any room, thanks to its modern aesthetics and low-profile build. Its dimensions allow it to fit snugly into various interior layouts, ensuring that it occupies minimal space while delivering maximum heat output.

A key feature of the RHFE-431WTA is its impressive heating capacity. With the ability to produce up to 4.2 kilowatts of heat, this unit can effectively warm spaces of various sizes. Whether it’s a cozy living area or a larger family room, the heater can adapt to your needs, providing comfortable temperatures even in the coldest months.

The Rinnai RHFE-431WTA also boasts advanced fan technology that distributes heat evenly throughout the room, eliminating cold spots and ensuring consistent warmth. Its whisper-quiet operation enhances the user experience, allowing you to enjoy a tranquil environment without the distraction of noisy heating equipment.

Energy efficiency is another major highlight of the RHFE-431WTA. This unit features a high energy efficiency rating, which not only reduces utility costs but also minimizes environmental impact. Its advanced combustion technology ensures that gas is burned optimally, contributing to lower emissions and a more sustainable heating solution.

The heater also includes an intelligent control system. With a user-friendly interface, homeowners can easily adjust settings to suit their comfort preferences. The unit comes equipped with a digital display that provides real-time information on temperature settings, operation modes, and timers, allowing for precise control over your heating needs.

Safety is a top priority for Rinnai, and the RHFE-431WTA is no exception. The heater is equipped with multiple safety features, including an automatic shut-off mechanism that activates if it detects any irregularities during operation. This ensures peace of mind for users, particularly in households with children or pets.

In summary, the Rinnai RHFE-431WTA gas heater stands out for its efficiency, advanced features, and stylish design. Whether you're looking to enhance comfort in your home or reduce energy consumption, this heater delivers on all fronts, making it a top choice in the market.