Rinnai RHFE-431WTA installation manual Programing the Timers Example

Page 31

PROGRAMING THE TIMERS : EXAMPLE cont...

7Press the “” button to set the pre-set

temperature to 76°F(remember, we are using the example schedule on page 28).

 

 

 

 

 

am

Set

 

 

 

 

 

Mo Tu We Th Fr

Select Program

 

 

1

Temp

 

 

 

 

 

 

 

 

 

Programming

Clock Select Timers

8Press the “Select” button again. Now the

am

Set

Programming

period 2 indicator will flash and the time and temperature display will be shown.

Mo Tu We Th Fr

Select Program Timer

2

Clock Select Timers

9

10

Press the “Select” button again. The

am

 

 

 

Programming

 

period indicator will become stable,

 

 

Clock

Select

Timers

2

 

 

 

 

 

 

the temperature display will go out and

Mo Tu We Th Fr

Select

Program

Timer

 

 

2

 

 

 

 

 

the clock indicator will flash.

 

 

 

 

 

 

Press the “” button until the display

 

 

 

 

Programming

 

am

 

 

 

 

 

shows “am8:00”(as in the example on

Mo Tu We Th Fr

Select

 

Clock

Select

Timers

page 28 for period ).

Program

Timer

 

 

2

 

 

 

 

 

2

 

 

 

 

 

11Press the “Select” button again. The clock

indicator will become stable, the pre-set temperature will flash and “Select Program Temp” will be shown.

 

 

 

 

 

am

Set

 

 

 

 

 

Mo Tu We Th Fr

Select Program

 

 

2

Temp

 

 

 

 

 

 

 

 

 

Programming

Clock Select Timers

12Press the “” button until the

temperature shows “- -” and the “OFF” indicator is displayed.

 

 

 

 

 

 

am

 

Set

 

 

 

 

 

 

Mo Tu We Th Fr

 

Select Program

 

 

2

OFF

Temp

 

 

 

 

 

 

 

 

 

 

 

Programming

Clock Select Timers

13

3

4

3

to

7

, and then go to step

14

.

 

Set periods and following/repeating steps

 

 

 

14Press the “Select” button again. The

am

Set

Programming

period 1 indicator will flash and “Sa Su” will be displayed.

Sa Su

Select Program Timer

1

Clock Select Timers

15 You can now program a Weekend schedule by repeating steps 3 to 7 , and then go to step 16 .

16Once all timers are programed, Press the

“Timers” button once to save all timer settings. The display will return to the current time and the “Set Program Timer” indicator will go out.

pm

Mo

Programming

Clock Select Timers

To review all of the programed settings turn to page 30- “WEEKLY TIMER REVIEW FUNCTION”.

For a description of how to operate the heater with these programed settings, turn to page 32- “OPERATING

THE TIMERS”.

– 29 –

Image 31
Contents RHFE-431WTA Table of Contents Safety Devices Features of the RHFE-431WTA UnitsGAS Conversion Specifications Technical DataIncluded in Carton Page General Information DimensionsSpecifications SpecificationsAIR Supply Safety Points Gasoline Getting to Know Your NEW RHFE-431 LED Display Mode OperationTemperatures Control PanelCUT-AWAY Diagram Page Installation Instructions GAS Connection Secure Heater to Wall Flue Manifold PositionWall Mounting Brackets Windowordoorthatmaybeopened Vent Termination ClearancesFlue Sizes Location / ClearancesSnow Areas Standard Installation of Flue ManifoldFIT Back Covers Sides only Method for Standard Walls Sleeve and Manifold InstallationProvided to compensate for weather board angle AIR Inlet Hose Fitting UnitLocking Clamp Screw Clamp and Insulation Instruct Customer on USE of Heater Operating Instructions Setting the Current Time & DAY Setting the ClockTo Open the Control Panel To turn the heater on Operating the Heater ManuallyTo turn the heater OFF OFF 3 4 OFF Auto Frost Man Override Select Progr Clock Temp R Programing the Weekly TimersExample Schedule Programing the Timers ExampleTimers Programing the Timers ExampleTo enter the Weekly Timer Review mode Weekly Timer Review FunctionTo exit the Weekly Timer Review mode Points to consider before writing your program Your Weekly Timer ProgramPoints to remember when writing your program Factory PRE-SET ProgramReturning to Manual Mode Operating the TimersFollow the steps below to operate the timers Period is on heating Period is OFF If the current timerOverride Function To turn on the Override functionTo turn off the Frost Protection Frost ProtectionEconomy Mode Information Energy Saving ModeTo turn on the Economy mode To turn off the Economy ModeTo activate the Function Lock Function LockTo deactivate the Function Lock Fault-Failure Procedure Testing UnitDuring Combustion PRE-SERVICE CheckWhen the unit is turned off At IgnitionTrouble Shooting Code Displayed Fault Remedy Error MessagesMaintenance Suggestions Maintenance / ServiceWiring Diagram Consumer Support Warranty InformationHeat Exchanger Year of Failure Allowance Schematic Diagram Page Page Page Page Parts List Page Page Page Part Name QTY Remarks Flow Diagram Rank Parts Name Parts no QTY Remarks Vent KIT Names and Numbers of Parts How to connect exhaust pipes Installing AN Extension KITMaximum extendable length How to connect air intake hoseTo prevent water condensation Qualified Installing Agency Page 431F-1720×0800 2008.09

RHFE-431WTA specifications

The Rinnai RHFE-431WTA is a sophisticated gas heater designed to provide efficient and reliable warmth for residential spaces. This innovative heating solution combines advanced technologies with user-friendly features, making it an ideal choice for homeowners seeking comfort without compromising on energy efficiency.

One of the standout characteristics of the RHFE-431WTA is its sleek, compact design. This gas heater can be easily integrated into any room, thanks to its modern aesthetics and low-profile build. Its dimensions allow it to fit snugly into various interior layouts, ensuring that it occupies minimal space while delivering maximum heat output.

A key feature of the RHFE-431WTA is its impressive heating capacity. With the ability to produce up to 4.2 kilowatts of heat, this unit can effectively warm spaces of various sizes. Whether it’s a cozy living area or a larger family room, the heater can adapt to your needs, providing comfortable temperatures even in the coldest months.

The Rinnai RHFE-431WTA also boasts advanced fan technology that distributes heat evenly throughout the room, eliminating cold spots and ensuring consistent warmth. Its whisper-quiet operation enhances the user experience, allowing you to enjoy a tranquil environment without the distraction of noisy heating equipment.

Energy efficiency is another major highlight of the RHFE-431WTA. This unit features a high energy efficiency rating, which not only reduces utility costs but also minimizes environmental impact. Its advanced combustion technology ensures that gas is burned optimally, contributing to lower emissions and a more sustainable heating solution.

The heater also includes an intelligent control system. With a user-friendly interface, homeowners can easily adjust settings to suit their comfort preferences. The unit comes equipped with a digital display that provides real-time information on temperature settings, operation modes, and timers, allowing for precise control over your heating needs.

Safety is a top priority for Rinnai, and the RHFE-431WTA is no exception. The heater is equipped with multiple safety features, including an automatic shut-off mechanism that activates if it detects any irregularities during operation. This ensures peace of mind for users, particularly in households with children or pets.