TESTING AND COMMISSIONING

TESTING PROCEDURE

Turn gas supply on and plug the unit into the power supply. (Caution 115V)

TO CHECK BURNER PRESSURE

Refer to rating plate.

Remove the wiring cover panel.

Remove test point plug and attach manometer to test point.

The test point is on the front injector block.

Light heater, turn to High heat setting and check pressure.

If adjustments are necessary, the regulator is situated on the front of the gas control.

After checking pressure, turn the unit off, remove manometer and replace test point plug.

Turn the heater on and off a few times to check ignition.

When you are satisfied that the heater is working correctly, reassemble panels.

All burner aeration is factory preset and cannot be adjusted.

If you are unable to get the unit to operate correctly, refer to Troubleshooting on Page 22 before contacting your local service contact as listed on Page 3.

It may take approximately 2 hours for the logs to achieve their full flame pattern and glow.

During the initial burning in period, some smoke and smell may be experienced. The heater should be run on the high position in a well ventilated room until these dissipate.

It is the responsibility of the installer to check that under normal operating conditions of the appliance, all flue gases are exhausted to the outside atmosphere and that there is no spillage of combustion gases into the room.

COMMISSIONING

INSTALLATION / COMMISSIONING CHECKLIST

Complete the installation checklist and the installer details on page 31 and make sure that this instruction book is left with the customer.

INSTRUCT CUSTOMER ON USE OF UNIT

Explain to the customer about use and care of unit. Make sure the customer understands the instructions.

EXPLAIN

Ignition (on / off), adjusting heat level, programming timers, flame setting, auto off, lock, override and the remote control.

NOTE:

THE MANUFACTURE RESERVES THE RIGHT TO CHANGE OR MODIFY SPECIFICATIONS WITHOUT NOTICE

18

Image 18
Contents IB35ETRN IB35ETRLC What to do if YOU Smell GASLimited Warranty Rinnai Fireplace Heater What is COVERED?Inbuilt Fire ETR Electronic Timer Remote Table of Contents ContactsSpecifications DimensionsImportant Points / Usage and Installation Musts Included in the cartonDiagram shows Minimum Clearances from Technical Specifications For Your Safety Read Before Operating Operating InstructionsTo Turn OFF GAS to Appliance Control Panel Layout OperationProgramming the on / OFF Timers Setting the ClockTimers / Preheat FlameOperating the Timers Remote ControlOverride To Replace Remote Control Battery Location FrontFireplace dimensions RUN GAS Supply VentingGAS Connection Purge Supply of AIR and DebrisRefer to the diagram opposite Electrical ConnectionLOG Installation Testing and Commissioning Maintenance Instructions Electric Motor Maintenance BurnersWiring Diagram PCB LayoutWiring DIAGRAM-LADDER Trouble Shooting Symptom Cause SolutionError Codes Error Code MessageExploded Diagrams Page Parts List Glass RET Bottom Assy PaintedFront Pilot Shield USA Painted Installation Notes Installation Notes Installation Notes Installation / Commissioning Checklist Installer DetailsNo YES Part Number 7919B

IB35ETRN, IB35ETRLC specifications

The Rinnai IB35ETRN and IB35ETRLC are advanced, energy-efficient heating solutions designed for residential and light commercial applications. These models belong to Rinnai's innovative range of condensing boilers, delivering exceptional performance while maximizing fuel efficiency.

One of the primary features of the Rinnai IB35ETRN and IB35ETRLC is their compact design. Both models are engineered to fit seamlessly into a variety of spaces, making them ideal for homes where space is at a premium. Their sleek, modern aesthetic complements contemporary décor, providing a discreet heating solution that does not compromise on performance.

The IB35ETRN and IB35ETRLC utilize cutting-edge condensing technology, which captures and reuses exhaust gases to enhance efficiency. This feature allows the boilers to achieve an impressive annual fuel utilization efficiency (AFUE) rating, making them not only environmentally friendly but also cost-effective in terms of energy consumption. Homeowners can appreciate reduced utility bills while maintaining comfortable indoor temperatures.

Another significant characteristic of these models is their modulating heating capacity. Both units can adjust their output based on the heating demands of the space, ensuring optimal comfort without unnecessary energy waste. This modulation capability means that the units can operate efficiently even in varying weather conditions, providing reliable warmth throughout the year.

The Rinnai IB35ETRN and IB35ETRLC are also designed with user-friendly interfaces that allow for easy operation and monitoring. Features such as programmable thermostats enable homeowners to set desired temperatures for different times of the day, further enhancing energy savings. The intuitive control systems provide clear displays of performance metrics, making it simple to manage heating requirements.

Safety and reliability are paramount, and both models are equipped with several protective features, including overload protection and automatic shutoff in the event of an issue. This technology ensures the safety of the home and adds peace of mind for users.

In summary, the Rinnai IB35ETRN and IB35ETRLC are state-of-the-art heating solutions that combine efficiency, compact design, and advanced technology. With their impressive AFUE ratings and modulating heating capacities, these models are ideal for those seeking reliable, energy-efficient heating systems for their homes or light commercial spaces. Rinnai's commitment to quality and innovation positions these boilers as top choices in today's market.