Rinnai IB35ETRN, IB35ETRLC installation manual Technical Specifications

Page 7

BEDDING MATERIAL, ET CETERA. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE ARE KEPT CLEAN.

34The glass window shall be replaced as one piece as supplied by the manufacturer. See log and glass installation on page 17.

35Do not substitute glass, glowing embers or logs. Use only glass, glowing embers and logs supplied by manufacturer.

36Caution: Do not operate unit with broken glass.

37WARNING: DO NOT OPERATE APPLIANCE WITH THE FRONT REMOVED, CRACKED OR BROKEN. REPLACEMENT OF THE GLASS SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON.

TECHNICAL SPECIFICATIONS

 

 

Natural Gas

Propane

Gas Input Rate:

 

Btu/hr

Btu/hr

 

Pilot:

200

200

 

Low:

11,000

11,000

 

High:

32,000

32,000

Minimum permissible

 

WC

WC

gas supply pressure for

 

Min:

7"

10"

purpose of input

Max:

10.5"

13"

adjustment

 

 

 

Gas Connection:

3/8" MNPT

 

 

Flue Termination:

An approved 4" vent cap must be fitted to all installations

Fan:

90 Watt 2 speed tangential

 

Combustion System:

Multi port burner and ceramic logs

 

Ignition System:

Continuous spark electronic ignition

 

Operation:

Finger touch control buttons or remote control

Temperature control:

Electronic thermostat High~Low / Off

 

 

Flame picture select option

 

 

Up / Down buttons

 

 

Temperature range:

Low = 50°F, 60°F~80°F, High 97°F

 

Safety Devices:

Flame failure- flame rod

 

 

Over heat - thermistors, thermal fuse

 

 

Power surge - 3 amp fuse

 

 

Room overheat - Automatic cut off at 104°F after 10 minutes

Fan delay

Micro computer timer

 

Combustion Method:

Naturally aspirated burner

 

Flue Type:

Approved B vent system

 

Heat transfer:

Direct radiation and forced convection

 

Installation Type:

Inbuilt

 

 

Flue Requirement:

Manufacturers minimum, 10 ft vertical.

 

 

Local codes may have a greater

 

requirement and must be followed

7

Image 7
Contents What to do if YOU Smell GAS IB35ETRN IB35ETRLCWhat is COVERED? Limited Warranty Rinnai Fireplace HeaterContacts Inbuilt Fire ETR Electronic Timer Remote Table of ContentsDimensions SpecificationsIncluded in the carton Important Points / Usage and Installation MustsDiagram shows Minimum Clearances from Technical Specifications Operating Instructions For Your Safety Read Before OperatingTo Turn OFF GAS to Appliance Operation Control Panel LayoutFlame Setting the ClockTimers / Preheat Programming the on / OFF TimersRemote Control Operating the TimersOverride To Replace Remote Control Battery Front LocationFireplace dimensions Purge Supply of AIR and Debris VentingGAS Connection RUN GAS SupplyElectrical Connection Refer to the diagram oppositeLOG Installation Testing and Commissioning Maintenance Instructions Burners Electric Motor MaintenancePCB Layout Wiring DiagramSymptom Cause Solution Wiring DIAGRAM-LADDER Trouble ShootingError Code Message Error CodesExploded Diagrams Page Glass RET Bottom Assy Painted Parts ListFront Pilot Shield USA Painted Installation Notes Installation Notes Installation Notes Installer Details Installation / Commissioning ChecklistNo YES Part Number 7919B

IB35ETRN, IB35ETRLC specifications

The Rinnai IB35ETRN and IB35ETRLC are advanced, energy-efficient heating solutions designed for residential and light commercial applications. These models belong to Rinnai's innovative range of condensing boilers, delivering exceptional performance while maximizing fuel efficiency.

One of the primary features of the Rinnai IB35ETRN and IB35ETRLC is their compact design. Both models are engineered to fit seamlessly into a variety of spaces, making them ideal for homes where space is at a premium. Their sleek, modern aesthetic complements contemporary décor, providing a discreet heating solution that does not compromise on performance.

The IB35ETRN and IB35ETRLC utilize cutting-edge condensing technology, which captures and reuses exhaust gases to enhance efficiency. This feature allows the boilers to achieve an impressive annual fuel utilization efficiency (AFUE) rating, making them not only environmentally friendly but also cost-effective in terms of energy consumption. Homeowners can appreciate reduced utility bills while maintaining comfortable indoor temperatures.

Another significant characteristic of these models is their modulating heating capacity. Both units can adjust their output based on the heating demands of the space, ensuring optimal comfort without unnecessary energy waste. This modulation capability means that the units can operate efficiently even in varying weather conditions, providing reliable warmth throughout the year.

The Rinnai IB35ETRN and IB35ETRLC are also designed with user-friendly interfaces that allow for easy operation and monitoring. Features such as programmable thermostats enable homeowners to set desired temperatures for different times of the day, further enhancing energy savings. The intuitive control systems provide clear displays of performance metrics, making it simple to manage heating requirements.

Safety and reliability are paramount, and both models are equipped with several protective features, including overload protection and automatic shutoff in the event of an issue. This technology ensures the safety of the home and adds peace of mind for users.

In summary, the Rinnai IB35ETRN and IB35ETRLC are state-of-the-art heating solutions that combine efficiency, compact design, and advanced technology. With their impressive AFUE ratings and modulating heating capacities, these models are ideal for those seeking reliable, energy-efficient heating systems for their homes or light commercial spaces. Rinnai's commitment to quality and innovation positions these boilers as top choices in today's market.