Rinnai IB35ETRN, IB35ETRLC installation manual Control Panel Layout, Operation

Page 9

CONTROL PANEL LAYOUT

For your convenience the controls on your new Flame Fire are situated under the cover on the top right-hand side of the fire and are accessed by simply lifting the lid. All necessary adjustments to the operation of your fire can be made with these controls.

OPERATION

• TURNING ON

Press the ON/OFF button to operate the unit. The ON indicator will glow green. The spark generator will be heard before the burner ignites and the ON indicator glows red, indicating that the burner is alight. Warm air can be felt coming from the louvres. The fan will come on automatically after 4 minutes.

If the unit does not ignite on initial use this may be due to air remaining in the gas supply line. The spark generator will only continue for 15 seconds. After this it will be necessary to press the ON/OFF button OFF, then ON again.

• TURNING OFF

Simply press the ON/OFF button to switch off the unit. The ON indicator will go out. The convection fan will continue to operate for several minutes after the burner has gone out in order to cool the appliance.

Do not turn off the heater by unplugging it from the wall. Do not unplug the heater while the convection

fan is running.

ROOM TEMPERATURE ADJUSTMENT

The room temperature and preset temperatures are only displayed and adjustable while the heater is running.

Press the ““ button to increase the

temperature setting or “ “ button to decrease the temperature setting. The temperatures can be preset to:

a)[L] low (50°F)

b)[61°F] to [79°F] in 1°F steps

c)[H] (97°F)

Once the pre-set temperature has been reached the burners will cycle between high and low (or high and pilot only depending on the auto off setting).

• LOCK

The LOCK function will help prevent accidental operation of the controls.

LOCK is activated by pressing the button and the LOCK indicator will glow. To

9

Image 9
Contents What to do if YOU Smell GAS IB35ETRN IB35ETRLCWhat is COVERED? Limited Warranty Rinnai Fireplace HeaterContacts Inbuilt Fire ETR Electronic Timer Remote Table of ContentsDimensions SpecificationsIncluded in the carton Important Points / Usage and Installation MustsDiagram shows Minimum Clearances from Technical Specifications For Your Safety Read Before Operating Operating InstructionsTo Turn OFF GAS to Appliance Operation Control Panel LayoutTimers / Preheat Setting the ClockProgramming the on / OFF Timers FlameOperating the Timers Remote ControlOverride To Replace Remote Control Battery Front LocationFireplace dimensions GAS Connection VentingRUN GAS Supply Purge Supply of AIR and DebrisElectrical Connection Refer to the diagram oppositeLOG Installation Testing and Commissioning Maintenance Instructions Burners Electric Motor MaintenancePCB Layout Wiring DiagramSymptom Cause Solution Wiring DIAGRAM-LADDER Trouble ShootingError Code Message Error CodesExploded Diagrams Page Glass RET Bottom Assy Painted Parts ListFront Pilot Shield USA Painted Installation Notes Installation Notes Installation Notes Installation / Commissioning Checklist Installer DetailsNo YES Part Number 7919B

IB35ETRN, IB35ETRLC specifications

The Rinnai IB35ETRN and IB35ETRLC are advanced, energy-efficient heating solutions designed for residential and light commercial applications. These models belong to Rinnai's innovative range of condensing boilers, delivering exceptional performance while maximizing fuel efficiency.

One of the primary features of the Rinnai IB35ETRN and IB35ETRLC is their compact design. Both models are engineered to fit seamlessly into a variety of spaces, making them ideal for homes where space is at a premium. Their sleek, modern aesthetic complements contemporary décor, providing a discreet heating solution that does not compromise on performance.

The IB35ETRN and IB35ETRLC utilize cutting-edge condensing technology, which captures and reuses exhaust gases to enhance efficiency. This feature allows the boilers to achieve an impressive annual fuel utilization efficiency (AFUE) rating, making them not only environmentally friendly but also cost-effective in terms of energy consumption. Homeowners can appreciate reduced utility bills while maintaining comfortable indoor temperatures.

Another significant characteristic of these models is their modulating heating capacity. Both units can adjust their output based on the heating demands of the space, ensuring optimal comfort without unnecessary energy waste. This modulation capability means that the units can operate efficiently even in varying weather conditions, providing reliable warmth throughout the year.

The Rinnai IB35ETRN and IB35ETRLC are also designed with user-friendly interfaces that allow for easy operation and monitoring. Features such as programmable thermostats enable homeowners to set desired temperatures for different times of the day, further enhancing energy savings. The intuitive control systems provide clear displays of performance metrics, making it simple to manage heating requirements.

Safety and reliability are paramount, and both models are equipped with several protective features, including overload protection and automatic shutoff in the event of an issue. This technology ensures the safety of the home and adds peace of mind for users.

In summary, the Rinnai IB35ETRN and IB35ETRLC are state-of-the-art heating solutions that combine efficiency, compact design, and advanced technology. With their impressive AFUE ratings and modulating heating capacities, these models are ideal for those seeking reliable, energy-efficient heating systems for their homes or light commercial spaces. Rinnai's commitment to quality and innovation positions these boilers as top choices in today's market.