Rinnai IB35ETRN Important Points / Usage and Installation Musts, Included in the carton

Page 5

IMPORTANT POINTS / USAGE AND INSTALLATION MUSTS

Unpack the heater and check for damage (DO NOT INSTALL DAMAGED HEATER). If the heater is damaged, contact your supplier for advice. Before installing the heater, check the label for the correct gas type (see rating plate, bottom right hand side of pillar). Refer to local gas authority for confirmation of the gas type if you are in doubt.

Included in the carton

Customer operation information.

IMPORTANT

Before using this product, please read this manual carefully to ensure proper use of the product:

1The installation must conform with local codes, or in the absence of local codes, the National Fuel Gas Code, ANSI Z223.1, or the Canadian Installation Code, CAN/CGA -B149.

2For information on gas type see the data plate on the heater.

3This heater must not be installed where curtains or other combustible materials could come into contact with it. In some cases curtains may need restraining.

4If you move, check the gas type in the area where you are moving to. The local gas authority will be able to advise on local regulations.

5This heater discharges a large volume of warm air to provide even heat distribution. If the air in the room contains cooking vapor or cigarette smoke, and the heater is used on a carpet, the surface of the carpet may become discolored. In addition, some nylon carpets contain dyes which may be affected by the warm air flow. Some soft vinyl surfaces are also subject to distortion, or discoloration by warm air. To prevent discoloration of carpets, etc., a mat should be placed in front of the appliance, extending about 30” in front of it.

6This heater must be installed on a hearth at least 2” thick and the width and depth of the heater.

7Read these rules and the instructions carefully. Check all local codes. Failure to follow these could cause a malfunction of the heater resulting in death, serious bodily injury and/or property damage.

8This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

9WARNING: Any change to this heater or its controls can be dangerous.

10If a gas leak is suspected, turn heater off, turn gas supply valve off at appliance connector valve. Open windows to ventilate area immediately and contact your dealer or gas company.

11DO NOT PLACE CLOTHING OR

FLAMMABLE MATERIALS, GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS, ON OR NEAR THE HEATER.

12Do not spray aerosols when the heater is in operation.

13YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEYARE IN THE SAME ROOM WITH THE HEATER.

14LPG containers must not be installed indoors.

15Do not use this appliance if any part has been under water. Immediately call a

5

Image 5
Contents What to do if YOU Smell GAS IB35ETRN IB35ETRLCWhat is COVERED? Limited Warranty Rinnai Fireplace HeaterContacts Inbuilt Fire ETR Electronic Timer Remote Table of ContentsDimensions SpecificationsIncluded in the carton Important Points / Usage and Installation MustsDiagram shows Minimum Clearances from Technical Specifications To Turn OFF GAS to Appliance For Your Safety Read Before OperatingOperating Instructions Operation Control Panel LayoutTimers / Preheat Setting the ClockProgramming the on / OFF Timers FlameOverride Operating the TimersRemote Control To Replace Remote Control Battery Front LocationFireplace dimensions GAS Connection VentingRUN GAS Supply Purge Supply of AIR and DebrisElectrical Connection Refer to the diagram oppositeLOG Installation Testing and Commissioning Maintenance Instructions Burners Electric Motor MaintenancePCB Layout Wiring DiagramSymptom Cause Solution Wiring DIAGRAM-LADDER Trouble ShootingError Code Message Error CodesExploded Diagrams Page Glass RET Bottom Assy Painted Parts ListFront Pilot Shield USA Painted Installation Notes Installation Notes Installation Notes No YES Installation / Commissioning ChecklistInstaller Details Part Number 7919B

IB35ETRN, IB35ETRLC specifications

The Rinnai IB35ETRN and IB35ETRLC are advanced, energy-efficient heating solutions designed for residential and light commercial applications. These models belong to Rinnai's innovative range of condensing boilers, delivering exceptional performance while maximizing fuel efficiency.

One of the primary features of the Rinnai IB35ETRN and IB35ETRLC is their compact design. Both models are engineered to fit seamlessly into a variety of spaces, making them ideal for homes where space is at a premium. Their sleek, modern aesthetic complements contemporary décor, providing a discreet heating solution that does not compromise on performance.

The IB35ETRN and IB35ETRLC utilize cutting-edge condensing technology, which captures and reuses exhaust gases to enhance efficiency. This feature allows the boilers to achieve an impressive annual fuel utilization efficiency (AFUE) rating, making them not only environmentally friendly but also cost-effective in terms of energy consumption. Homeowners can appreciate reduced utility bills while maintaining comfortable indoor temperatures.

Another significant characteristic of these models is their modulating heating capacity. Both units can adjust their output based on the heating demands of the space, ensuring optimal comfort without unnecessary energy waste. This modulation capability means that the units can operate efficiently even in varying weather conditions, providing reliable warmth throughout the year.

The Rinnai IB35ETRN and IB35ETRLC are also designed with user-friendly interfaces that allow for easy operation and monitoring. Features such as programmable thermostats enable homeowners to set desired temperatures for different times of the day, further enhancing energy savings. The intuitive control systems provide clear displays of performance metrics, making it simple to manage heating requirements.

Safety and reliability are paramount, and both models are equipped with several protective features, including overload protection and automatic shutoff in the event of an issue. This technology ensures the safety of the home and adds peace of mind for users.

In summary, the Rinnai IB35ETRN and IB35ETRLC are state-of-the-art heating solutions that combine efficiency, compact design, and advanced technology. With their impressive AFUE ratings and modulating heating capacities, these models are ideal for those seeking reliable, energy-efficient heating systems for their homes or light commercial spaces. Rinnai's commitment to quality and innovation positions these boilers as top choices in today's market.