Installation Instructions

General Instructions

Do not use substitute materials.

Use only parts certified with the appliance.

A qualified service technician should install the appliance and inspect it before use.

If you move, check the gas type in your new area. The local gas authority will be able to advise on local regulations.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.

A manufactured home (USA only) or mobile home OEM installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is not applicable, the standard for Manufactured Home Installations, ANSI/NCSBCS A225.1, or the standard for Gas Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4.

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.

Appliance input ratings are based on sea level operation and need not be changed for operation up to 2000 ft (609.9 m) elevation. For operation at elevations above 2000 ft (609.9 m), refer to the Conversion Manual.

The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).

The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).

If the flooring is carpet, tile, or other combustible material other than wood, then the appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.

This appliance discharges a large volume of warm air next to the floor. Any particles in the air such as cigarette smoke could cause discoloration in nylon carpets containing dyes or vinyl surfaces.

This appliance is not designed to built in.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. If conversion of the unit is needed, conversions must be performed by a qualified service provider at the owner’s expense.

This appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance.

Rinnai suggests that a dedicated electrical circuit with a 120VAC, 60 hz, 10 amp power source be used.

A test plug are provided for testing of manifold differential pressure. It is located on the modulating gas valve.

The appliance should be correctly sized for the space it is required to heat.

Follow the installations instructions and those in Care and Maintenance for adequate combustion and ventilation air.

The flow of combustion and ventilation air shall not be obstructed.

Clearances to access the appliance during servicing are 2 inches (50 mm) from the sides, 40 inches (1 m) from the front, and 10 inches (250 mm) from the top.

14

Rinnai Corporation ES38 Manual

Image 14
Contents ES38 RHFE-1004RFA Table of Contents Safety Behavior and Practices Consumer Safety InformationSafety Definitions Appliance Specifications SpecificationsSafety Features Features Flue ManifoldsOperating Instructions Getting to know your new heating applianceControl Panel Operation LampOperating the Heater Adjusting the TemperatureEconomy Mode Turning the heater onLock Sensible Temperature ControlAdjusting Air Flow Direction Adding Water to the HumidifierCare and Maintenance Before Making a Service Call At IgnitionFault Codes Code Displayed Fault RemedyTroubleshooting Restart FunctionInstallation Instructions General InstructionsGas Connection Clearances to CombustiblesFlue Terminal Clearances Description Canadian Installations US Installations Flue Terminal ClearancesDimensions Inches mmInstallation Parts Attach Back Spacers Drilling Flue HoleAttach Wall Brackets Flue Manifold Installation Flue Manifold Installation Extension Kit Installation ExamplesClearances Installing the Exhaust LineConnecting the Air Intake Hose ClampsExtension Kits and Parts RingConnecting the Appliance For Your Safety Read Before Operating Operating InstructionsCut-Away Diagram Wiring Diagram EquivalentLadder Diagram Parts List Parts List Parts List Parts List Parts List Parts List Parts List Rinnai Corporation ES38 Manual QTY Part Number Part Name CAP Operation Label Consumer Support Warranty InformationLimited Warranty Gas Direct Vent Wall FurnaceWhat is not covered? Rinnai’s other fine products