Rinnai ES38 Flue Terminal Clearances, Description Canadian Installations US Installations

Page 17

Flue Terminal Clearances

Ref

Description

Canadian Installations

US Installations

 

 

 

 

 

Clearance above grade, veranda,

 

 

A

porch, deck, or balcony. (Take into

12 inches (30 cm)

12 inches (30 cm)

 

account the anticipated snow line)

 

 

 

 

 

 

 

 

6 inches (15 cm) for

6 inches (15 cm) for

 

 

appliances < 10,000 BTUh;

appliances < 10,000 BTUh;

B

Clearance to window or door that may

12 inches (30 cm) for

9 inches (23 cm) for

appliances > 10,000 BTUh

appliances > 10,000 BTUh

be opened

 

and < 100,000 BTUh,

and < 50,000 BTUh,

 

 

 

 

36 inches (91 cm) for

12 inches (30 cm) for

 

 

appliances > 100,000 BTUh

appliances > 50,000 BTUh

C

Clearance to permanently closed

*

*

 

 

 

 

 

Vertical clearance to ventilated soffit,

 

 

D

located above the terminal within a

*

*

horizontal distance of 2 feet (61 cm)

 

 

 

 

from the center line of the terminal

 

 

 

 

 

 

E

Clearance to unventilated soffit

*

*

 

 

 

 

F

Clearance to outside corner

*

*

 

 

 

 

G

Clearance to inside corner

20 inches (50 cm)

20 inches (50 cm)

 

 

 

 

 

Clearance to each side of center line

3 feet (91 cm) within a height

 

H

extended above meter/regulator

15 feet (4.5 m) above the

*

 

assembly

meter/regulator assembly

 

 

 

 

 

I

Clearance to service regulator vent

3 feet (91 cm)

*

 

 

 

 

 

 

6 inches (15 cm) for

6 inches (15 cm) for

 

 

appliances < 10,000 BTUh;

appliances < 10,000 BTUh;

 

Clearance to nonmechanical air supply

12 inches (30 cm) for

9 inches (23 cm) for

J

inlet to building or the combustion air

appliances > 10,000 BTUh

appliances > 10,000 BTUh

 

inlet to any other appliance

and < 100,000 BTUh,

and < 50,000 BTUh,

 

 

36 inches (91 cm) for

12 inches (30 cm) for

 

 

appliances > 100,000 BTUh

appliances > 50,000 BTUh

K

Clearance to a mechanical air supply

6 feet (1.83 m)

3 feet (91 cm) above if within

inlet

10 feet (3 m) horizontally

 

 

 

 

 

 

L

Clearance above paved sidewalk or

7 feet (2.13 m) 1

*

paved driveway located on public

 

 

 

 

 

 

 

 

Clearance under veranda, porch, deck,

12 inches (30 cm) to non-

12 inches (30 cm) to non-

M

flammables 2

flammables 2

or balcony

24 inches (60 cm) to

24 inches (60 cm) to

 

 

 

flammables 2

flammables 2

 

 

 

 

1A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.

2Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor. For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, clearances are in accordance with local

installation codes and the requirements of the gas supplier.

Rinnai Corporation ES38 Manual

17

Image 17
Contents ES38 RHFE-1004RFA Table of Contents Safety Behavior and Practices Consumer Safety InformationSafety Definitions Appliance Specifications SpecificationsSafety Features Flue Manifolds FeaturesGetting to know your new heating appliance Operating InstructionsOperation Lamp Control PanelEconomy Mode Adjusting the TemperatureOperating the Heater Turning the heater onAdjusting Air Flow Direction Sensible Temperature ControlLock Adding Water to the HumidifierCare and Maintenance At Ignition Before Making a Service CallCode Displayed Fault Remedy Fault CodesRestart Function TroubleshootingGeneral Instructions Installation InstructionsClearances to Combustibles Gas ConnectionFlue Terminal Clearances Flue Terminal Clearances Description Canadian Installations US InstallationsInches mm DimensionsInstallation Parts Attach Back Spacers Drilling Flue HoleAttach Wall Brackets Flue Manifold Installation Flue Manifold Installation Examples Extension Kit InstallationConnecting the Air Intake Hose Installing the Exhaust LineClearances ClampsRing Extension Kits and PartsConnecting the Appliance Operating Instructions For Your Safety Read Before OperatingCut-Away Diagram Equivalent Wiring DiagramLadder Diagram Parts List Parts List Parts List Parts List Parts List Parts List Parts List Rinnai Corporation ES38 Manual QTY Part Number Part Name CAP Operation Label Limited Warranty Warranty InformationConsumer Support Gas Direct Vent Wall FurnaceWhat is not covered? Rinnai’s other fine products