Flue Terminal Clearances
Ref | Description | Canadian Installations | US Installations | |
|
|
|
| |
| Clearance above grade, veranda, |
|
| |
A | porch, deck, or balcony. (Take into | 12 inches (30 cm) | 12 inches (30 cm) | |
| account the anticipated snow line) |
|
| |
|
|
|
| |
|
| 6 inches (15 cm) for | 6 inches (15 cm) for | |
|
| appliances < 10,000 BTUh; | appliances < 10,000 BTUh; | |
B | Clearance to window or door that may | 12 inches (30 cm) for | 9 inches (23 cm) for | |
appliances > 10,000 BTUh | appliances > 10,000 BTUh | |||
be opened | ||||
| and < 100,000 BTUh, | and < 50,000 BTUh, | ||
|
| |||
|
| 36 inches (91 cm) for | 12 inches (30 cm) for | |
|
| appliances > 100,000 BTUh | appliances > 50,000 BTUh | |
C | Clearance to permanently closed | * | * | |
|
|
|
| |
| Vertical clearance to ventilated soffit, |
|
| |
D | located above the terminal within a | * | * | |
horizontal distance of 2 feet (61 cm) | ||||
|
|
| ||
| from the center line of the terminal |
|
| |
|
|
|
| |
E | Clearance to unventilated soffit | * | * | |
|
|
|
| |
F | Clearance to outside corner | * | * | |
|
|
|
| |
G | Clearance to inside corner | 20 inches (50 cm) | 20 inches (50 cm) | |
|
|
|
| |
| Clearance to each side of center line | 3 feet (91 cm) within a height |
| |
H | extended above meter/regulator | 15 feet (4.5 m) above the | * | |
| assembly | meter/regulator assembly |
| |
|
|
|
| |
I | Clearance to service regulator vent | 3 feet (91 cm) | * | |
|
|
|
| |
|
| 6 inches (15 cm) for | 6 inches (15 cm) for | |
|
| appliances < 10,000 BTUh; | appliances < 10,000 BTUh; | |
| Clearance to nonmechanical air supply | 12 inches (30 cm) for | 9 inches (23 cm) for | |
J | inlet to building or the combustion air | appliances > 10,000 BTUh | appliances > 10,000 BTUh | |
| inlet to any other appliance | and < 100,000 BTUh, | and < 50,000 BTUh, | |
|
| 36 inches (91 cm) for | 12 inches (30 cm) for | |
|
| appliances > 100,000 BTUh | appliances > 50,000 BTUh | |
K | Clearance to a mechanical air supply | 6 feet (1.83 m) | 3 feet (91 cm) above if within | |
inlet | 10 feet (3 m) horizontally | |||
|
| |||
|
|
|
| |
L | Clearance above paved sidewalk or | 7 feet (2.13 m) 1 | * | |
paved driveway located on public | ||||
|
|
| ||
|
|
|
| |
| Clearance under veranda, porch, deck, | 12 inches (30 cm) to non- | 12 inches (30 cm) to non- | |
M | flammables 2 | flammables 2 | ||
or balcony | 24 inches (60 cm) to | 24 inches (60 cm) to | ||
| ||||
|
| flammables 2 | flammables 2 | |
|
|
|
|
1A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.
2Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor. ∗For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, clearances are in accordance with local
installation codes and the requirements of the gas supplier.