Rinnai R50LSI, R98LSI Space Heating, Temperature Setting, Pumps, Replacement, Iron Components

Page 39

Space Heating

If the water heater is to be used for both water (potable) heating and space heating then the following apply.

The piping and components connected to the water heater shall be suitable for use with potable water.

Toxic chemicals, such as used for boiler treatment, shall not be introduced into the potable water.

The water heater shall not be connected to any heating system or components previously used with a nonpotable water heating appliance.

When the system requires water for space heating at temperatures higher than required for other uses, a means such as a mixing valve shall be installed to temper the water for other uses in order to reduce the scald hazard potential.

Space heating applications are considered commercial applications for warranty purposes.

Temperature Setting

When using this appliance to provide domestic hot water it is recommended that the domestic hot water temperature be reduced to acceptable temperatures in accordance with local codes. In the absence of local codes it is recommended that the domestic hot water temperature be set to 140º F (60º C) or lower in accordance with UPC 501.6 by using mixing valves or the temperature controller for the water heater.

Pumps

Only use pumps of brass or stainless steel construction. Do not use pumps of iron construction as they will oxidize and clog the inlet filter on the appliance.

Pumps circulating water through the water heater must be sized to overcome the pressure loss through the water heater, the heating system, and any additional plumbing pressure losses. The pressure drop curve based on the water heater model is provided in this manual.

Replacement

When replacing an existing space heating application’s water heating source (boiler, tank water heater, tankless water heater, etc.) with Rinnai water heaters, ensure that the water heaters are sized to adequately provide the necessary BTU input for the desired space heating application. Rinnai water heaters are designed to maintain a constant outlet temperature and will supply only the necessary amount of BTU’s to maintain that temperature. Depending on the application the maximum BTU rating of the unit may not be achieved. Contact Rinnai’s Applications Engineering Department for assistance at (800) 621-9419 ext. 4490.

Iron Components

Do not use Rinnai water heaters directly for space heating applications involving iron radiators or applications with any iron components. Iron components may oxidize creating rust that will clog the inlet filter of the Rinnai water heater.

VA Series Indoor LS Manual

39

Image 39
Contents ANS Z21.10.3 CSA REU-VA3237FFUTable of Contents R50LSi R75LSi R94LSi R98LSi SpecificationsConsumer Safety Information Safety DefinitionsSafety Behavior and Practices Safety Features Operating Instructions Features Available on Temperature ControllersFeatures Description of OperationMC-91-1US & MCC-91-1US Temperature Controllers ModelsBC-100V-1US Temperature Options Without a Temperature Controller Setting the TemperatureMCC-91 Temperature Controller Temperature RangesSetting the Sound Volume Voice Prompt Model Temperature Settings Available ºFUsing the Water Smart / Bath Fill Function Setting the Water VolumeOverview Models MC-91 and MCC-91 Setting Controller to MuteSetting the Clock Filling the TubMaintenance Code Fault Remedy Error CodesCode Trouble Shooting for Common Issues Accessing Operating InformationWater Quality Circulating Pump Flushing the Heat Exchanger Error Code LC orGeneral Instructions Installation InstructionsAttachment of the Water Heater Clearances from ApplianceElectrical Connection Gas PipingGeneral Instructions Pipe Sizing Procedure Example Water Piping Pressure Relief ValveFreeze Protection Rinnai Water Heater Freeze Protection PipingRinnai Water Heater Recommended Piping for Basic InstallationFor this application Recommended Piping for Circulation SystemsFor this application Optional Piping for Circulation SystemsVenting Instructions Intake / Exhaust GuidelinesCondensate Maximum Vent Length Manufacturer Product Parts Vent ProductsFlue Terminal Clearances ANS Z21.10.3 CSA Vent Terminal Area Where Terminal is not PermitttedAdditional Clearances Vent Terminal Flue Installation Concentric Venting R50LSi, R75LSi, R85LSi Venting Clearances to Combustibles Flue Installation R98LSi, R98LSi-ASMEAir Intake Assembly Exhaust Pipe AssemblyVertical Terminations Horizontal with Concentric TerminationGuidelines High Altitude InstallationsConnecting Multiple Water Heaters Number of Connected Water Heaters Accessories NecessaryCable Lengths and Size Temperature Controller InstallationConfigurations LocationOutline of Remote Mounting the ControllerOperating Instructions For Your Safety Read Before OperatingTechnical Data Pressure Drop CurveOutlet Flow Data Pumps Temperature SettingReplacement Space HeatingR50LSi, R75LSi, R94LSi R98LSi, R98LSi-ASME DimensionsHOT Ladder DiagramWarranty Information Limited WarrantyConsumer Support What will Rinnai do? Rinnai’s other fine products

R50LSI, R94LSI, R75LSI, R98LSI-ASME, R98LSI specifications

The Rinnai R50LSI, R75LSI, R94LSI, R98LSI, and R98LSI-ASME are high-efficiency tankless water heaters designed for residential and commercial applications. Each model in this line-up boasts unique features and technologies that cater to varying hot water needs while emphasizing energy efficiency and reliability.

The R50LSI is the most compact option in the lineup, providing up to 5.1 gallons per minute (GPM) of hot water at a 35°F rise in temperature. It is an ideal choice for smaller households or apartments where space is a premium. It operates using a direct vent system, ensuring safe exhaust of combustion gases outside the home. The R75SLI, with a maximum output of 7.5 GPM, is suited for needs such as multiple showers running simultaneously, making it perfect for medium-sized homes.

Moving on to the R94LSI and R98LSI, these models provide even greater capacity and efficiency. The R94LSI offers an impressive 9.4 GPM flow rate, while the R98LSI reaches a peak of 9.8 GPM, supporting larger family requirements and ensuring hot water availability for multiple applications concurrently. Both models incorporate Rinnai’s advanced Circ-Logic technology, which allows users to set schedules for recirculating hot water, minimizing wait time and enhancing convenience.

For commercial applications, the R98LSI-ASME is a specialized model that includes the American Society of Mechanical Engineers (ASME) certification. This makes it suitable for larger facilities, such as restaurants, schools, and other institutions that demand a robust and efficient solution for comprehensive hot water needs.

All these models feature a user-friendly digital controller, enabling easy temperature adjustments and real-time monitoring. Moreover, their compact design means they can be installed in various locations, saving valuable space. The Rinnai tankless water heaters utilize a highly efficient condensing technology, resulting in a lower carbon footprint and reduced energy costs.

With a robust warranty program and the reliability that Rinnai is known for, the R50LSI, R75LSI, R94LSI, R98LSI, and R98LSI-ASME embody the pinnacle of water heating technology. These models not only provide the convenience of on-demand hot water but also contribute to energy conservation, making them an excellent choice for environmentally conscious consumers.