Rinnai R94LSI Setting the Temperature, Temperature Options Without a Temperature Controller

Page 8

Setting the Temperature

1. Press the “Priority button” on the temperature controller. The green Priority light will glow indicating that this controller is controlling the temperature and that the Rinnai water heater is ready to supply hot water.

The priority can only be changed while no hot water is running.

2.Press the ▲ or ▼ buttons to obtain the desired temperature setting.

All hot water sources are able to provide water at this temperature setting until it is changed again at this or another temperature controller.

Temperature Options Without a Temperature Controller

The default temperature setting for this appliance

120º F (49º C)

140º F (60º C)

installed without a temperature controller is 120º F (49º C). If desired the temperature setting can be changed to 140º F (60º C) by adjustment of a dip switch.

Set dip switch 5 to ON to obtain 140º F water temperature setting.

Set dip switch 5 to OFF (default) to obtain 120º F water temperature setting.

Switch No.

ON

O1

F

F 2

3

4

5

6

7

8

Switch No.

ON

O1

F

F 2

3

4 5 6 7 8

8

VA Series Indoor LS Manual

Image 8
Contents REU-VA3237FFU ANS Z21.10.3 CSATable of Contents Specifications R50LSi R75LSi R94LSi R98LSiSafety Behavior and Practices Safety Features Consumer Safety InformationSafety Definitions Features Available on Temperature Controllers FeaturesDescription of Operation Operating InstructionsTemperature Controllers Models MC-91-1US & MCC-91-1USBC-100V-1US Setting the Temperature Temperature Options Without a Temperature ControllerTemperature Ranges Setting the Sound Volume Voice PromptModel Temperature Settings Available ºF MCC-91 Temperature ControllerOverview Using the Water Smart / Bath Fill FunctionSetting the Water Volume Setting Controller to Mute Setting the ClockFilling the Tub Models MC-91 and MCC-91Maintenance Error Codes Code Fault RemedyCode Water Quality Trouble Shooting for Common IssuesAccessing Operating Information Flushing the Heat Exchanger Error Code LC or Circulating PumpInstallation Instructions General InstructionsClearances from Appliance Attachment of the Water HeaterGeneral Instructions Electrical ConnectionGas Piping Pipe Sizing Procedure Example Freeze Protection Water PipingPressure Relief Valve Freeze Protection Piping Rinnai Water HeaterRecommended Piping for Basic Installation Rinnai Water HeaterRecommended Piping for Circulation Systems For this applicationOptional Piping for Circulation Systems For this applicationCondensate Venting InstructionsIntake / Exhaust Guidelines Maximum Vent Length Vent Products Manufacturer Product PartsVent Terminal Area Where Terminal is not Permittted Flue Terminal Clearances ANS Z21.10.3 CSAAdditional Clearances Vent Terminal Flue Installation Concentric Venting R50LSi, R75LSi, R85LSi Flue Installation R98LSi, R98LSi-ASME Air Intake AssemblyExhaust Pipe Assembly Venting Clearances to CombustiblesHorizontal with Concentric Termination Vertical TerminationsHigh Altitude Installations Connecting Multiple Water HeatersNumber of Connected Water Heaters Accessories Necessary GuidelinesTemperature Controller Installation ConfigurationsLocation Cable Lengths and SizeMounting the Controller Outline of RemoteFor Your Safety Read Before Operating Operating InstructionsOutlet Flow Data Technical DataPressure Drop Curve Temperature Setting ReplacementSpace Heating PumpsDimensions R50LSi, R75LSi, R94LSi R98LSi, R98LSi-ASMELadder Diagram HOTConsumer Support Warranty InformationLimited Warranty What will Rinnai do? Rinnai’s other fine products

R50LSI, R94LSI, R75LSI, R98LSI-ASME, R98LSI specifications

The Rinnai R50LSI, R75LSI, R94LSI, R98LSI, and R98LSI-ASME are high-efficiency tankless water heaters designed for residential and commercial applications. Each model in this line-up boasts unique features and technologies that cater to varying hot water needs while emphasizing energy efficiency and reliability.

The R50LSI is the most compact option in the lineup, providing up to 5.1 gallons per minute (GPM) of hot water at a 35°F rise in temperature. It is an ideal choice for smaller households or apartments where space is a premium. It operates using a direct vent system, ensuring safe exhaust of combustion gases outside the home. The R75SLI, with a maximum output of 7.5 GPM, is suited for needs such as multiple showers running simultaneously, making it perfect for medium-sized homes.

Moving on to the R94LSI and R98LSI, these models provide even greater capacity and efficiency. The R94LSI offers an impressive 9.4 GPM flow rate, while the R98LSI reaches a peak of 9.8 GPM, supporting larger family requirements and ensuring hot water availability for multiple applications concurrently. Both models incorporate Rinnai’s advanced Circ-Logic technology, which allows users to set schedules for recirculating hot water, minimizing wait time and enhancing convenience.

For commercial applications, the R98LSI-ASME is a specialized model that includes the American Society of Mechanical Engineers (ASME) certification. This makes it suitable for larger facilities, such as restaurants, schools, and other institutions that demand a robust and efficient solution for comprehensive hot water needs.

All these models feature a user-friendly digital controller, enabling easy temperature adjustments and real-time monitoring. Moreover, their compact design means they can be installed in various locations, saving valuable space. The Rinnai tankless water heaters utilize a highly efficient condensing technology, resulting in a lower carbon footprint and reduced energy costs.

With a robust warranty program and the reliability that Rinnai is known for, the R50LSI, R75LSI, R94LSI, R98LSI, and R98LSI-ASME embody the pinnacle of water heating technology. These models not only provide the convenience of on-demand hot water but also contribute to energy conservation, making them an excellent choice for environmentally conscious consumers.