FOR YOUR SAFETY READ BEFORE OPERATING

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

OPERATING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat to lowest setting.

3.Turn off all electric power to the appliance using the ON/OFF button.

4.This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

5.Locate the manual gas valve on the side of the heater. Turn the manual valve

clockwise to the full OFF position.

Manual Valve

CLOSE OPEN

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell

gas, STOP! Follow “B” in the safety information above. If you don,t smell gas, go to the next step.

7.Turn the manual gas valve counterclockwise to the

full ON position.

8.Turn on all electric power to the appliance using the ON/OFF button.

9.Set the thermostat to desired setting.

10.Open a hot water tap. If the appliance will not operate, follow the instructions “To Turn Off Gas To Appliance” and call your service technician or gas supplier. See manual for additional information.

TO TURN OFF GAS TO APPLIANCE

1.Turn off all electric power to the appliance using the ON/OFF button.

2.Set the thermostat to lowest setting.

3.Locate the manual gas valve on the side of the heater. Turn the manual valve clockwise to the full

OFF position.

VA Series Outdoor LS Manual

33

Image 33
Contents ANS Z21.10.3 CSA REU-VA3237WTable of Contents R63LSe R75LSe R94LSe R98LSe SpecificationsConsumer Safety Information Safety DefinitionsSafety Behaviors and Practices Safety Features Features Features Available on Temperature ControllersDescription of Operation Operating InstructionsMC-91-1US & MCC-91-1US Temperature Controllers ModelsBC-100V-1US Temperature Options Without a Temperature Controller Setting the TemperatureSetting the Sound Volume Voice Prompt Temperature RangesRe-setting the Maximum Temperature MCC-91 Temperature ControllerUsing the Water Smart / Bath Fill Function Setting the Water VolumeOverview Setting the Clock Setting Controller to MuteFilling the Tub Models MC-91 and MCC-91Maintenance Error Codes Error Code TableError Fault Remedy Code Trouble Shooting for Common Issues Accessing Operating InformationWater Quality Rinnai Water Heater Flushing the Heat Exchange Error Code LC orGeneral Instructions Installation InstructionsAttachment of the Water Heater Clearances from ApplianceElectrical Connection Gas PipingGeneral Instructions Pipe Sizing Procedure Example Water Piping Pressure Relief ValveFreeze Protection Rinnai Water Heater Freeze Protection PipingQTY Recommended Piping for Basic InstallationFor this application Recommended Piping for Circulation SystemsYears On Heat Exchanger Years On Parts Optional Piping for Circulation SystemsFlue Terminal Clearances ANS Z21.10.3 CSA Description Canadian Installations US Installations Additional Clearances Vent Terminal Connecting Multiple Water Heaters High Altitude InstallationsR98LSe, R98LSe-ASME, R94LSe, R75LSe GuidelinesConfigurations Temperature Controller InstallationLocation Cable Lengths and SizeMounting on the wall Outline of Temperature controllerConnecting to the R63LSe Operating Instructions For Your Safety Read Before OperatingTechnical Data Pressure Drop CurveOutlet Flow Data Replacement Temperature SettingSpace Heating PumpsR63LSe, R75LSe, R94LSe R98LSe, R98LSe-ASME DimensionsHOT Ladder DiagramWarranty Information Limited WarrantyConsumer Support What will Rinnai do? Rinnai’s other fine products 103 International Drive

R98LSE-ASME specifications

The Rinnai R98LSE-ASME is a high-efficiency tankless water heater that stands out for its powerful performance and advanced technology. This model is particularly designed to meet the demands of residential and commercial applications, delivering consistent hot water whenever it is needed. With a maximum flow rate of 9.8 gallons per minute, it is able to provide hot water for multiple outlets simultaneously, making it an excellent choice for busy households and commercial settings.

One of the main features of the Rinnai R98LSE-ASME is its Energy Star rating, which signifies its exceptional energy efficiency. This rating not only helps reduce energy bills but also minimizes the environmental impact by consuming less gas over time. The unit is engineered with advanced condensing technology, which captures and reuses heat from exhaust gases, enhancing efficiency and cutting waste.

The R98LSE-ASME operates on a natural gas or propane option, allowing for flexibility depending on the available fuel supply. Its powerful burner system can quickly heat water to the desired temperature, ensuring that there's no waiting time for hot water. Additionally, the unit is designed with a temperature lock feature, which allows users to set and maintain their preferred water temperature easily, enhancing safety and convenience, especially in households with children.

Installation of the Rinnai R98LSE-ASME is straightforward, as it comes with a detailed manual and can be fitted into various environments, including closets and small spaces, due to its compact design. This versatility provides significant savings on space compared to traditional tank water heaters.

Safety is also a priority for Rinnai. The R98LSE-ASME includes a comprehensive set of safety features such as overheat protection, freeze protection, and built-in diagnostic codes for quick troubleshooting. This ensures reliable operation and peace of mind for users.

In summary, the Rinnai R98LSE-ASME is a high-performance tankless water heater that combines efficiency, reliability, and advanced technology. With features such as a high flow rate, Energy Star certification, and robust safety measures, it is well-suited for both residential and commercial applications, making it a worthy investment for anyone seeking a dependable hot water solution.