Rinnai R98LSE-ASME installation manual Pipe Sizing Procedure Example

Page 20

Gas Piping

Pipe Sizing Procedure - Example

The gas supply must be capable of handling the entire gas load at the location. Gas line sizing is based on gas type, the pressure drop in the system, the gas pressure supplied, and gas line type. Refer to the National Fuel Gas Code, NFPA 54, for proper gas line sizing. The below information is provided as an example.

1.Determine the cubic feet per hour of gas required by dividing the gas input (on the rating plate) by the heating value of the gas (available from the local gas company). The gas input needs to include all gas products at the location and the maximum BTU usage at full load when all gas products are in use.

Gas Input of Rinnai water heater (BTU / HR)

Cubic Feet per Hour (CFH) =

Heating Value of Gas (BTU / FT 3 )

2.Use the table for your gas type to find the pipe size required for your cubic feet per hour of gas and your pipe length.

Example: The heating value of propane gas for your location is 2516 BTU / FT 3. The gas input of the R94LSe is 199,000 BTU/HR. Additional appliances at the location require 75,000 BTU/HR.

Therefore the cubic feet per hour = (199,000+75,000) / 2516 = 108.9 FT 3/ HR.

If the pipe length is 100 ft then the 3/4 inch pipe size capable of supplying 197 FT 3/ HR of propane gas will be adequate.

Length

 

Pipe Size (inches)

 

 

 

 

 

3/4

1

1 1/4

1 1/2

 

 

 

 

 

 

10

273

514

1060

1580

 

 

 

 

 

20

188

353

726

1090

 

 

 

 

 

30

151

284

583

873

 

 

 

 

 

40

129

243

499

747

 

 

 

 

 

50

114

215

442

662

 

 

 

 

 

60

104

195

400

600

 

 

 

 

 

70

95

179

368

552

 

 

 

 

 

80

89

167

343

514

 

 

 

 

 

90

83

157

322

482

 

 

 

 

 

100

79

148

304

455

 

 

 

 

 

125

70

131

269

403

 

 

 

 

 

150

63

119

244

366

 

 

 

 

 

175

58

109

224

336

 

 

 

 

 

200

54

102

209

313

 

 

 

 

 

Length

 

Pipe Size (inches)

 

 

 

 

 

1/2

3/4

1

1 1/4

 

 

 

 

 

 

10

291

608

1150

2350

 

 

 

 

 

20

200

418

787

1620

 

 

 

 

 

30

160

336

632

1300

 

 

 

 

 

40

137

287

541

1110

 

 

 

 

 

50

122

255

480

985

 

 

 

 

 

60

110

231

434

892

 

 

 

 

 

80

101

212

400

821

 

 

 

 

 

100

94

197

372

763

 

 

 

 

 

125

89

185

349

716

 

 

 

 

 

150

84

175

330

677

 

 

 

 

 

175

74

155

292

600

 

 

 

 

 

200

67

140

265

543

 

 

 

 

 

20

VA Series Outdoor LS Manual

Image 20
Contents REU-VA3237W ANS Z21.10.3 CSATable of Contents Specifications R63LSe R75LSe R94LSe R98LSeSafety Behaviors and Practices Safety Features Consumer Safety InformationSafety Definitions Features Available on Temperature Controllers FeaturesDescription of Operation Operating InstructionsTemperature Controllers Models MC-91-1US & MCC-91-1USBC-100V-1US Setting the Temperature Temperature Options Without a Temperature ControllerTemperature Ranges Setting the Sound Volume Voice PromptRe-setting the Maximum Temperature MCC-91 Temperature ControllerOverview Using the Water Smart / Bath Fill FunctionSetting the Water Volume Setting Controller to Mute Setting the ClockFilling the Tub Models MC-91 and MCC-91Maintenance Error Fault Remedy Error CodesError Code Table Code Water Quality Trouble Shooting for Common IssuesAccessing Operating Information Flushing the Heat Exchange Error Code LC or Rinnai Water HeaterInstallation Instructions General InstructionsClearances from Appliance Attachment of the Water HeaterGeneral Instructions Electrical ConnectionGas Piping Pipe Sizing Procedure Example Freeze Protection Water PipingPressure Relief Valve Freeze Protection Piping Rinnai Water HeaterRecommended Piping for Basic Installation QTYRecommended Piping for Circulation Systems For this applicationOptional Piping for Circulation Systems Years On Heat Exchanger Years On PartsFlue Terminal Clearances ANS Z21.10.3 CSA Description Canadian Installations US Installations Additional Clearances Vent Terminal High Altitude Installations Connecting Multiple Water HeatersR98LSe, R98LSe-ASME, R94LSe, R75LSe GuidelinesTemperature Controller Installation ConfigurationsLocation Cable Lengths and SizeOutline of Temperature controller Mounting on the wallConnecting to the R63LSe For Your Safety Read Before Operating Operating InstructionsOutlet Flow Data Technical DataPressure Drop Curve Temperature Setting ReplacementSpace Heating PumpsDimensions R63LSe, R75LSe, R94LSe R98LSe, R98LSe-ASMELadder Diagram HOTConsumer Support Warranty InformationLimited Warranty What will Rinnai do? Rinnai’s other fine products 103 International Drive

R98LSE-ASME specifications

The Rinnai R98LSE-ASME is a high-efficiency tankless water heater that stands out for its powerful performance and advanced technology. This model is particularly designed to meet the demands of residential and commercial applications, delivering consistent hot water whenever it is needed. With a maximum flow rate of 9.8 gallons per minute, it is able to provide hot water for multiple outlets simultaneously, making it an excellent choice for busy households and commercial settings.

One of the main features of the Rinnai R98LSE-ASME is its Energy Star rating, which signifies its exceptional energy efficiency. This rating not only helps reduce energy bills but also minimizes the environmental impact by consuming less gas over time. The unit is engineered with advanced condensing technology, which captures and reuses heat from exhaust gases, enhancing efficiency and cutting waste.

The R98LSE-ASME operates on a natural gas or propane option, allowing for flexibility depending on the available fuel supply. Its powerful burner system can quickly heat water to the desired temperature, ensuring that there's no waiting time for hot water. Additionally, the unit is designed with a temperature lock feature, which allows users to set and maintain their preferred water temperature easily, enhancing safety and convenience, especially in households with children.

Installation of the Rinnai R98LSE-ASME is straightforward, as it comes with a detailed manual and can be fitted into various environments, including closets and small spaces, due to its compact design. This versatility provides significant savings on space compared to traditional tank water heaters.

Safety is also a priority for Rinnai. The R98LSE-ASME includes a comprehensive set of safety features such as overheat protection, freeze protection, and built-in diagnostic codes for quick troubleshooting. This ensures reliable operation and peace of mind for users.

In summary, the Rinnai R98LSE-ASME is a high-performance tankless water heater that combines efficiency, reliability, and advanced technology. With features such as a high flow rate, Energy Star certification, and robust safety measures, it is well-suited for both residential and commercial applications, making it a worthy investment for anyone seeking a dependable hot water solution.