Rinnai R98LSE-ASME installation manual Temperature Ranges, Setting the Sound Volume Voice Prompt

Page 9

Temperature Ranges

This water heater will attempt to provide hot water at the temperature setting even when the water flow is varied or when more than 1 tap is in use. The water heater can deliver water at only one temperature setting at a time. The available temperatures for a given model are provided below.

Model

 

 

 

 

Temperature Settings Available (ºF)

 

 

 

 

R63LSe

98

100

102

104

106

108

110

115

120

125

130

135

140

150

160

 

R75LSe

 

 

 

 

 

 

 

 

 

*

*

*

*

**

**

 

R94LSe

 

 

 

 

 

 

 

 

 

125

130

135

140

150

160

185

R98LSe

98

100

102

104

106

108

110

115

120

R98LSe-ASME

 

 

 

 

 

 

 

 

 

*

*

*

*

**

**

**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temp in Celsius ºC

37

38

39

40

41

42

43

46

49

52

54

57

60

66

71

85

*

*

*

*

**

**

**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Re-setting the Maximum Temperature

If the model name on the side of the water heater ends with “-UC” (ex. “REU-VA2535WD-UC”), then these units have a default maximum temperature of 120º F (49º C) and an option to increase the maximum temperature to 140 ºF (60 ºC). Temperature settings from 125-140 ºF (52-60 ºC) are available by setting dip switch 6 to ON in the SW1 bank of 8 dip switches.

Units with model names ending in “-US” have a default maximum temperature of 140 ºF (60 ºC).

**MCC-91 Temperature Controller

These settings require the MCC-91 controller. When the MCC-91 controller is connected, these higher temperatures are available on all controller models in the system. Use of an MCC-91 controller in a residential dwelling will reduce the warranty coverage to that of a commercial warranty application.

The MCC-91 controller is intended for commercial and hydronic applications only. If an MCC-91 controller is used in a residential dwelling for a hydronics application, a mixing valve must also be installed to limit the potable hot water temperature to a safe temperature. Water temperatures over 125º F (51º C) can cause severe burns or scalding. Refer to the Danger Alert on water temperatures. Rinnai shall not, in any event, be liable for damages resulting from such misuse or misapplication.

Suggested temperatures are

Kitchen

120 ºF (49º C)

Shower

98º - 110º F (37º - 43º C)

Bath Fill

102º - 110º F (39º - 43º C)

These temperatures are suggestions only.

A temperature lower than 98º F (37º C) can be obtained at the tap by mixing with cold water.

To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the “On/Off“ button for 5 seconds while the water heater is OFF.

Setting the Sound Volume (Voice Prompt)

MC-100VPress the “Function” button to adjust the voice prompt volume. The default sound volume is set to Medium. Each subsequent press of the or button cycles through the volume levels in the order below.

Medium Volume

Off Volume

BC-100VPress the “Sound Vol.” button to adjust the voice prompt volume. The default sound volume is set to Medium. Each subsequent press of the button cycles through the volume levels in the order below.

Off Sound

(default)

High Volume

(beep)

 

(no beep)

Low Volume

VA Series Outdoor LS Manual

9

Image 9
Contents ANS Z21.10.3 CSA REU-VA3237WTable of Contents R63LSe R75LSe R94LSe R98LSe SpecificationsConsumer Safety Information Safety DefinitionsSafety Behaviors and Practices Safety Features Features Features Available on Temperature ControllersDescription of Operation Operating InstructionsMC-91-1US & MCC-91-1US Temperature Controllers ModelsBC-100V-1US Temperature Options Without a Temperature Controller Setting the TemperatureSetting the Sound Volume Voice Prompt Temperature RangesRe-setting the Maximum Temperature MCC-91 Temperature ControllerUsing the Water Smart / Bath Fill Function Setting the Water VolumeOverview Setting the Clock Setting Controller to MuteFilling the Tub Models MC-91 and MCC-91Maintenance Error Codes Error Code TableError Fault Remedy Code Trouble Shooting for Common Issues Accessing Operating InformationWater Quality Rinnai Water Heater Flushing the Heat Exchange Error Code LC orGeneral Instructions Installation InstructionsAttachment of the Water Heater Clearances from ApplianceElectrical Connection Gas PipingGeneral Instructions Pipe Sizing Procedure Example Water Piping Pressure Relief ValveFreeze Protection Rinnai Water Heater Freeze Protection PipingQTY Recommended Piping for Basic InstallationFor this application Recommended Piping for Circulation SystemsYears On Heat Exchanger Years On Parts Optional Piping for Circulation SystemsFlue Terminal Clearances ANS Z21.10.3 CSA Description Canadian Installations US Installations Additional Clearances Vent Terminal Connecting Multiple Water Heaters High Altitude InstallationsR98LSe, R98LSe-ASME, R94LSe, R75LSe GuidelinesConfigurations Temperature Controller InstallationLocation Cable Lengths and SizeMounting on the wall Outline of Temperature controllerConnecting to the R63LSe Operating Instructions For Your Safety Read Before OperatingTechnical Data Pressure Drop CurveOutlet Flow Data Replacement Temperature SettingSpace Heating PumpsR63LSe, R75LSe, R94LSe R98LSe, R98LSe-ASME DimensionsHOT Ladder DiagramWarranty Information Limited WarrantyConsumer Support What will Rinnai do? Rinnai’s other fine products 103 International Drive

R98LSE-ASME specifications

The Rinnai R98LSE-ASME is a high-efficiency tankless water heater that stands out for its powerful performance and advanced technology. This model is particularly designed to meet the demands of residential and commercial applications, delivering consistent hot water whenever it is needed. With a maximum flow rate of 9.8 gallons per minute, it is able to provide hot water for multiple outlets simultaneously, making it an excellent choice for busy households and commercial settings.

One of the main features of the Rinnai R98LSE-ASME is its Energy Star rating, which signifies its exceptional energy efficiency. This rating not only helps reduce energy bills but also minimizes the environmental impact by consuming less gas over time. The unit is engineered with advanced condensing technology, which captures and reuses heat from exhaust gases, enhancing efficiency and cutting waste.

The R98LSE-ASME operates on a natural gas or propane option, allowing for flexibility depending on the available fuel supply. Its powerful burner system can quickly heat water to the desired temperature, ensuring that there's no waiting time for hot water. Additionally, the unit is designed with a temperature lock feature, which allows users to set and maintain their preferred water temperature easily, enhancing safety and convenience, especially in households with children.

Installation of the Rinnai R98LSE-ASME is straightforward, as it comes with a detailed manual and can be fitted into various environments, including closets and small spaces, due to its compact design. This versatility provides significant savings on space compared to traditional tank water heaters.

Safety is also a priority for Rinnai. The R98LSE-ASME includes a comprehensive set of safety features such as overheat protection, freeze protection, and built-in diagnostic codes for quick troubleshooting. This ensures reliable operation and peace of mind for users.

In summary, the Rinnai R98LSE-ASME is a high-performance tankless water heater that combines efficiency, reliability, and advanced technology. With features such as a high flow rate, Energy Star certification, and robust safety measures, it is well-suited for both residential and commercial applications, making it a worthy investment for anyone seeking a dependable hot water solution.